by jasode · 10y ago · 0 comments
>"This means that the decline in installed cost observed since 2012 was largely caused by a decline in the cost of the inverters that convert the DC power produced by solar panels to AC power for the grid and other “soft” costs such as customer acquisition, system design, installation, and permitting."
On another note, calculating the payback of residential solar panels is tricky because many online calculators don't consider:
- inverters failing and needing to be replaced (~10 years?)
- bank of backup batteries need to be replaced (~10 years?)
- significant increased labor costs of replacing the roof or repair roof leaks (roofers must spend extra time unmounting all panels before replacing shingles or tiles.)
- paying a service to clean the panels if the house is in a dusty climate and the homeowner doesn't want to climb on the roof and do it himself
One can lump all those negative costs into one bucket called "ongoing maintenance" to simplify things but nevertheless, it doesn't seem like many ROI calculators properly account for them.(That said, some people pay the premium for solar panels to gain power autonomy which overrides any over-optimistic estimates of installation payback.)
Backup batteries are still relatively rare, as they should be - they are fairly expensive as backup power. Most systems remain grid tied. Smaller systems don't require retail net metering for a solid payback, since almost all of the energy is used as it is produced.
Roof repair is again, real, but not as likely as you might think. Asphalt shingles under an array are protected from wind, and even more importantly, heat. They degrade at half the rate of the rest of the roof. Assuming 12-15 years for roof replacement, you will hit the module warrantied life of ~25 years before you need to replace the roof underneath the array.
Cleaning the panels really only comes into play when the pitch of the roof is relatively shallow (3 on 12 or shallower). Otherwise rain will clean them fairly well. A lot of people won't have any trouble walking such a shallow pitched roof, and will simply hose the panels off once in a while.
Also, in general, the price of modules per watt is about half of what it was 5 years ago. Peripherals are a major component of the improved economics, but module prices themselves have mattered just as much.
> On another note, calculating the payback of
> residential solar panels is tricky because many
> online calculators don't consider (stuff...)
Sometimes they do, we installed Solar in 2003, we replaced a failed inverter in 2016. At the time we installed the system we got a new roof with asphalt shingles (50 year roof) which both helped the roof load (they were lighter than the previous wood shake) and was a time period longer than the payback period for our panels.IMO that's the best comparison for domestic storage though.
Sure, you have to either trust that nat gas is available or deal with fuel, but a propane tank isn't obscenely expensive considering that it bumps your backup from hours to days/weeks.
Ehh? A Powerwall costs $3500 alone, WITHOUT the inverter or transfer switch. A Powerwall supplies 3.3 kW, which isn't enough to run a 3-ton air conditioning unit (30 amps x 240 Volts == 7.2 kW).
If you run 15kW (air conditioner plus a few other stuff), you'll need FIVE Power walls for a minimum price of $17500. (Plus the inverter, plus... etc. etc.)
----------
Or, you can get a 16kW generator AND switch for $3300.
http://www.electricgeneratorsdirect.com/Generac-Guardian-646...
-------
Powerwall is actually a lot more expensive than standard generators. Something like 5x more expensive.
Insulating your property to keep heat out/in is a hell of a lot cheaper than buying enough backup power to keep your A/C running...
Wow, it always surprises me how much Americans waste and consider it totally normal(I bet you are American, in the rest of the world it would be difficult to emit that expression with a straight face).
Have you considered alternatives? My house in sunny Spain spends less than 1Kwatt in August pumping water in a pipeline in the soil that has a big thermal inertia, and small air conditioning units for the air.
You don't need more if you have good insulation.
So even your massive A/C should be useable for a while during daylight hours if your solar system is large enough. Most people here in humid hurricane country opt to have a 15 amp 120v window unit available instead, and limit themselves to a single comfortable room.
I guess the solar panels would protect the roof a bit, but I'd expect a bad hail storm to be bad news for those, too.
Over the last few years racks, mounts, wiring, inverters and labor have made up ~60% of the cost.
Plus, Obama started slapping ~30% tariffs on the cheapest imported solar panels.
http://www.bloomberg.com/news/articles/2015-07-09/u-s-impose...
I read the state department report too. The 'disguised subsidies' they called China out on included 'advertising' the solar companies' existence on local government websites.
Clearly they didn't expect anybody to actually read that.