by macemoneta · 16y ago · 0 comments
Erm. Actually they get their performance because they write to NAND instead of spinning platters. SSD controllers are also quite a bit smarter than plain RAID0.
RAID0 works very well with good quality drives.
A RAID0 over three disks has about 1/3 the MTBF of a single disk.
That can still be a worthwhile trade-off if you need the extra capacity, but if you're mostly after performance and reliability then a pair of SSDs, or even a single SSD, is the better choice.
http://www.denali.com/wordpress/index.php/dmr/2010/02/02/ssd-interfaces-and-performance-effects
Also, while RAID0 reduces the MTBF, it's not linear. Drive life is not magically shortened as a result of the drive being in a RAID array (if you take care to isolate synchronous vibration). The life of the array is equal to the shortest drive life. In other words, if a drive would have failed after 25,000 hours in standalone operation, it will still fail in 25,000 hours in an array. The other drives may run to 100,000 hours, but it's a "weakest link" failure mode.Well, it is inverse proportional.
The life of the array is equal to the shortest drive life.
Erm. To be clear: Your risk of having a RAID0-set (over 3 disks) fail during a given timespan is 3 times higher than having a single-disk-"set" fail in the same timespan.
In other words, if a drive would have failed after 25,000 hours in standalone operation, it will still fail in 25,000 hours in an array.
That calculation makes no sense. If you have a single drive then that will fail, on average, after 25k hours. If you stripe over three of these drives then your array will, on average, fail after 8333 hours.
For example, if there were a probability of 5% that the disk would fail within three years, in a three disk RAID0 array, that probability of failure would be:
P=(1-(1-.05)^3)=.14263
In other words, 14.3% probability of failure within three years. That doesn't mean it will fail in that time frame. It means if you have a large population of that configuration, that is the rate you would be dealing with for drive replacement planning.
The MTBF and MTTF calculations apply to populations of drives (e.g. a given model) not to a given drive. The values provide no predictability for the failure of any specific drive. Using the values for that purpose is a common misapplication. A drive with a MTTF of 1,000,000 power-on hours can fail in 15 minutes or never during its useful life.
As a result, a three drive array will have a higher probability of failure over a given interval, but the MTTF/MTBF of the drives is essentially unchanged.
Think of it this way... The probability of winning the lottery is one in 20,000,000. The probability that someone (anyone) will win the lottery in a given week may be one out of ten - 10%. In other words, some person wins the lottery, on average, one time in ten weeks. That doesn't mean that your probability of winning the lottery is 10%. It also doesn't mean that the average probability of winning the lottery is 10%. It also doesn't change the probability of winning the lottery; it's still one in 20,000,000, even if three people win in a 10 week interval.