by Animats · 7y ago · 0 comments
This thing looks like a giant mechanical kludge. If you put the brake (the paddles in water part) at the top of the tower, you have to pump water up the tower. If you put it at the bottom of the tower, you need a top gearbox with a right-angle bevel drive, a bearing ring supporting the gearbox so it can face the wind, long shafting, and bearings. Some early power turbines were built that way, but nobody does that any more.
Vertical axis turbines like the Savonius turbine and Darrieus rotor can be used, but they're not very efficient, so you need a big one. They also are hard to shut down in an overspeed condition; they can't change direction, change blade pitch, or tilt upward, so you need a strong emergency brake system. Which is why they're rarely seen any more.
All this outdoor hot water plumbing needs to be well insulated, or you lose most of the heat. So a field of wind turbines, or one unit some distance from where the heat is wanted, is a problem. Moving energy around over wires is so much simpler.
Driving a heat pump mechanically might work better, but that's because heat pumps are far more efficient than heaters. (Moving heat is much cheaper than making it. See [1]). An electric windmill driving a heat pump is probably less hassle.
[1] https://dothemath.ucsd.edu/2012/06/heat-pumps-work-miracles/
You have a windmill, so you have a source of energy to do that. Much of the mechanical energy that goes into the pumping becomes gravitational potential energy, which will become heat when the water goes back down the tower. A lot of the rest will be lost as heat during pumping. Either way, it's ending up as heat, which is what you want.
Heaters are the only type of machine which are naturally efficient!
I had a big argument with my physics teacher about this back in highschool. He was so stuck on the "no machine is 100% efficient" dogma that he couldn't look past it to the definition of "efficiency" for a heater in a closed room.
However, "efficiency" is actually a value judgement. You probably want to heat something specific, so you're going to lose some fractional efficiency by accidentally heating something else. Resistance in the wires leading to your heater will accidentally heat the outside of your house.
It's also not a terribly useful definition of efficiency environmentally: if you multiply the efficiency of burning fuel to produce the electricity by the efficiency of your electric heater, you get a worse result than burning fuel in your home. And it's not a terribly useful definition as a consumer either, since that electrical heater is only producing about 50% the heat that a heat pump could do with that electricity.
https://dothemath.ucsd.edu/2012/06/heat-pumps-work-miracles/
Probably 99.many_9s efficient, but I don't think it could be 100%.
(We'll assume you're talking about a resistive heater, fire, or so on. Not a heat pump where you can play games with the meaning of 100% efficient)
It does. The Calorius windmill was commercially produced for about a decade, 40 of them were sold. Seventeen of these windmills were still operating in 2012.
It's all in the article. Also your points about the savonius are addressed.
On the contrary, it is cheap, uncomplicated and very efficient in the modern context - by using the electric power to run a reverse cycle AC unit (in most cases, existing) you will get around 10 times the heat that a water brake system might deliver, with lower cost and much higher reliability.
Sunlight has a power of ~2kw/m^2 in visible spectrum (solar panels cannot capture all of this). At a strong breeze (10m/s) wind has a power of ~1kw/m^2 (windmills cannot capture all of this). So the mechanical heat generation would have to be more than twice as efficient to electrical generation to be worthwhile. But the "complications" mentioned are really what kill wind.
You want to capture sunlight: solar panels on the roof. No real obstruction.
You want to capture wind: massive windmills on your roof, need to disable the fan blade if the wind exceeds a certain value. Moving parts wear out.
I am not going to install a 2m radius windmill on my roof. Two 1m radius windmills have 1/2 of the area and are still an eye sore. Four 1/2m radius windmills, 1/4 of the area of the 2m radius blade.
Reference: https://russell.ballestrini.net/hybrid-hot-water-heater-save...
The drag force in the fluid brake is proportional to the velocity squared. So you get harder and harder braking. (The air blades still need to not blow off though.)
Insulation requirements decrease with the size of the reservoir. (Since volume increases faster than area.) Besides, the reservoir could be placed inside the house as well.
For the mechanical+pump permutation, the plumbing needs to provide a way to prime the pump, and the pump cannot be more than 20-something feet up without the whole system being pressurised [1]. So, if you go that route, a pump near ground level will more-or-less be required.
[1] http://processengineering.co.uk/article/2019233/maximum-suct...
Dunno how to stop it at strong winds though.