by kabdib · 4y ago · 0 comments
It was not awesome seeing a bunch of servers go dark in just about the order we had originally powered them on. Not a fun day at all.
And that they were sold by HP or Dell, and manufactured by SanDisk.
Do I win a prize?
(None of us win prizes on this one).
Unbelievable. Thank you for sharing your experience!
Edit: here's why I like this theory. I don't believe that the two disks had similar levels of wear, because the primary server would get more writes than the standby, and we switched between the two so rarely. The idea that they would have failed within hours of each other because of wear doesn't seem plausible.
But the two servers were set up at the same time, and it's possible that the two SSDs had been manufactured around the same time (same make and model). The idea that they hit the 40,000 hour mark within a few hours of each other seems entirely plausible.
Mike of M5 (mikiem in this thread) told us today that it "smelled like a timing issue" to him, and that is squarely in this territory.
This thread is making me feel a lot less crazy.
[1] https://www.reddit.com/r/sysadmin/comments/f5k95v/dell_emc_u...
The lesson I learned is that the three replacements went to different arrays and we never again let drives from the same batch be part of the same array.