by joerichey · 4y ago · 0 comments
It seems like if the ITU decides to keep the leap second (a bad idea, in my opinion), the large infrastructure providers will just use the same standard smear for their clocks.
Few others will do anything so idiotic.
The Facebook smear is asymmetrical so it starts off 1 second off just after the leap second, and subsequently corrects itself.
[ The reason Google and Amazon use a linear smear is because NTP clients try to measure the rate difference between their local clock and the reference clocks; if that is different every time the NTP client queries its servers, it will have trouble locking on and accurately matching the smear curve. You can mitigate this somewhat by fixing a higher NTP query frequency, but that’s a heavy-handed fix for an engineering mistake. ]