by towaway15463 · 4y ago · 0 comments
Single strand solid aluminum conductors expand and contract due to heat changes from high draw, they can work themselves loose, and eventually create shorts and fires. They make special connectors so you can remedy this by attaching a small piece of copper wire (a pigtail) to the aluminum, and don't need to replace all the wiring in your house. This of course means that we could just legislate for better connectors throughout the building, as we should do anyways, and we could safely use single strand solid conductor aluminum wiring instead of copper virtually everywhere.
As is NOT required. This is old old info: antioxidant paste is not just not required, in some places you will fail inspection if add it, and other electricians might laugh at you for not keeping up to date.
> expand and contract due to heat changes from high draw, they can work themselves loose
Nope, this is also not true. It's simply that there is a new allow of aluminum used today (since 1975) which retains its strength under heating and this problem is solved.
> This of course means that we could just legislate for better connectors throughout the building
Connector rated for Cu/Al are widely available, and not hard to make. There's just no market for it for smaller wires since everyone got scared and no one wants to install aluminum anymore.
It doesn't have to be that way, the current alloy is 47 years old at this point. People just don't want to change.
Some of the problems with aluminum wiring and whether all problems are solved:
https://inspectapedia.com/aluminum/Aluminum_Wiring_Hazards.p...
Requirement for antioxidant paste whenever manufacturer requires it (most of the time).
https://www.howtolookatahouse.com/Blog/Entries/2022/1/is-ant...
> I don't agree with your conclusion that everything is now ok and it's just nerves.
What issues do you find? All you need is a connector rated Cu/AlR and that's it.
But seriously though, since when did Laissez-faire economics and legislation ever lead to sufficient safety not to kill people or burn down their homes willy-nilly?
HN is the only place I visit that has such wild ideas as "safety regs are too burdensome, let the free market sort it out".
Contrast that to 250,000 deaths per year (in the USA) by medical mistakes or preventable adverse effects.
At some point, we have to decide where to put our efforts. Electrical safety is arguably oversolved - ie. we put too much effort into it compared to the safety gain of any extra effort, compared to medical accidents which is likely undersolved. Even simple things like requiring a doctor to not do more than an 8 hour shift, like we require of truck drivers, would probably save a lot of lives.
The idea of 'more safety is always better' needs to be broken.
I did not suggest throwing out any existing regulation, merely that we don't need more regulation.
Surely you can not argue that we need an infinite amount of more regulation? There must be some level that's enough?
See builders/landlords and insulation.
If buyer or renters are totally oblivious, why offer any features at all?
Connectors could be copper, the wire itself could be aluminium, completely sealed in pvc.
12- or 14- AWG wire is extremely easy to terminate correctly.
For service connections and large scale power distribution where trained professionals are already required and lack of maintenance is already a fire hazard, it isn't a problem.
For small branch circuits where work is often done by random Joe's and where any sort of preventative maintenance is few and far between, it is a failed experiment.
Either way, home and commercial construction is likely to crater (already starting in many areas) due to cost of $$ going up, so that should help tamp down demand quite a bit.
The aluminum wires of today are a different allow of that simply does not have the problem anymore. It's a solved issue. You don't even need anti-ox on the connection.
Not that you can buy small gauge aluminum wiring anyway.
We can discuss the theory behind changing it of course, it just isn’t material to the field until the rules change.