by 0x53 · 4y ago · 0 comments
However, what I have found in the process is that for well insulated homes GSHP probably doesn’t make sense.
Originally I was considering buying a kit from this site: https://www.123zeroenergy.com/pricing/geo-thermal.html
But like it says on the page, because air source heat pumps have been getting a lot better they no longer sell the kits. There are a couple of individuals on YouTube who have used similar GSHP kits and had good success. The main challenge is that you need to dig 100ft of deep trenches per ton of cooling. Edit: should be 300ft not 100
https://weatherspark.com/y/71566/Average-Weather-in-G%C3%B6t...
in contrast sunshine duration and angle in Winter is frickin low.
sure that guy wasn't trying to sell sth?
https://www.heatpumps.ca/articles/best-low-temperature-heat-...
I'd love to believe that modern ones are better, but its hard to pull the trigger on them after years of suffering.
I currently have oil heat, and love it. Nice hot (not luke warm) air. And if the power goes out, I just fire up a generator and I have good heat, because the blower doesn't take much to run. Having been w/o power for stretches as long as a week during winter, that is a massive benefit over electric heat.
My considerations for going with ground source heat pump were:
* the maximum amount of solar that I could install is enough for ground source heat pump, but is a bit short for air source,
* what if the seasonal electricity prices get so extreme, that the grid can't maintain 1:1 ratio for the net billing system anymore?
* what if the global temperature swings become more extreme?
Particularly noise and heat locality. Two properties that combined are not very cosy.
For older building even replacing wood furnace with air to water system is enough.
It also has the extra benefit of heating up your ground for the winter period.
This sort of take is unwise. It makes zero sense to invest today in domestic systems with the expectation that at some point in the future there will be extreme events a hand full of times throughout the year. The benefit of shaving a fraction of a percent from the baseline outweighs multipercent gains of hypothetical extreme events that happen a few times a year.
When building spend as much as you can on the building envelope (preventing air, vapor, water movement) and insulation.
Those cannot be easily changed at all, but you can relatively easily add another heating or cooling device.
And if you build above code minimums (you should!) be sure to have someone knowledgeable calculate the actual heating/cooling load. If you don’t, the HVAC contractor may assume code minimums and oversize the system.
Or get systems that are entirely variable.
And get every step inspected! Mid build blower door tests are a great thing to do (right after the air seal envelope is up).
Mitsubishi, specifically, makes a heat pump with the marketing vernacular, "H2i" or "hyper heat" which has reasonable efficiency down to -13F/-25C.
My mini-split system worked fine down to about 10F, then it was defrosting for 10 minutes after every 8 minutes of use or so. I just turned on crypto miners on a few computers to supplement. Laptop crypto mining is useful if you want to keep your hands and wrists warm, hats, blankets, sweaters, and some old 100+ watt light bulbs will also help.
All this is to say "you can just get a -30 degree capable system" is out of reach for most people in the world. A large swath of people geographically close to my house still use window or wall HVAC units, rather than ducted systems. I was the only split ductless system my HVAC installer had ever installed - they had to come fix their install 4 times (four!) and eventually i contacted the asurion purchase protection people and got refunded for the cost of the HVAC system.
it works fine now, i told the HVAC installer to cut the threaded connectors off everything and sweat all the copper lines together, and it hasn't had an issue since.
it was always breaking in the late fall and early spring, where it had to heat at night but cool during the day, it would always break around 11AM. The pressure differentials must have been an afterthought in the design, i guess.