The biggest differentiator is if the building has mechanical ventilation and to what extent this mechanical ventilation uses fresh air vs internal circulation.
In unventilated crowded spaces like e.g. classrooms, we regularly see CO2 exceeding 3500 ppm. [1]
However in classrooms with a well designed ventilation system you can keep the CO2 < 1000ppm during the whole school day.
What the author did in his hotel room to turn on the fan or play around with the A/C settings is a good idea but many hotels Hvac systems do not draw in sufficient fresh air and you will see high CO2 developments.
[1] https://www.airgradient.com/open-airgradient/blog/we-measure...
...wait, that's not helping?
That is, along with measuring temperature, the sensors in each room should also measure CO2 levels. If CO2 is rising, fans can be turned on/turned up to bring more fresh air into the room.
As buildings approach airtightness, this becomes essential. I was expecting more in this area from the IoT crowd, but they never delivered. It's the old-school HVAC systems which do this.
Some years back I went to an IoT meeting in San Francisco, in a beautifully converted industrial building in Dogpatch on the waterfront. Big windows and skylights, with openable windows driven by manual chain falls on both. Ceiling fans. Plus a standard HVAC system. Was all of this coordinated in any way? No.
The place should have had motor drives on the windows. They were all on two long shafts, so it wouldn't be all that hard. As the place filled up with people, the skylights should be opened and the ceiling fans driven to blow upward and exhaust hot air and C02. Open the bay-facing windows slightly for intake air. As the evening went on and outside temperature dropped, close the bay-facing windows, continuing to monitor CO2 and temperature. If heating, open a damper to take air from the outside as necessary to keep the CO2 down. When everybody leaves, flush the air for a few minutes, then close everything up, turn off the fans, and let the temperature drop a few degrees.
The place should have been a showpiece for intelligent building control. But what were they pushing? Refrigerators with a tablet built into the door, for more than the cost of a refrigerator plus an iPad. The tablet had no useful interaction with the refrigerator; it was just a general use tablet.
Even home "smart thermostats" don't do much. They need this set of sensors, plus an external air damper so they can switch from recirculate to outside air as necessary. And the ability to run fans, without AC or heat as necessary. But that requires actual installation, which neither Amazon nor Apple can competently handle.
All this stuff saves enough energy to pay for itself.
[1] https://buildings.honeywell.com/gb/en/products/by-category/s...
In fancier homes they can control the ventilation per room, though the standard is that they control the ventilation for the entire house.
Where does "opening the windows" fit in a scale of "well designed ventilation systems" ?
I'm not being flip, or snarky - I'm serious.
I don't think it's terribly sophisticated or haughty to consider lack of opening windows to be a poverty.
Hotel rooms, hospital rooms, classrooms ... whatever ... windows that cannot be opened is a poverty.
it's much more common to wish for bigger windows because you're hot than because you're falling asleep
by virtue of stuffing 30 people into a single room you force them to compromise on environmental conditions; whoever's out in the tails of the distribution or has low social status is going to get screwed over because the resulting compromise will favor average people and people of high social status
that's just how compromises work, people struggle to promote their conflicting interests, so popular people and people with popular interests win
but typically you can still find a compromise that's pretty okay for 90+% of people
(1000 ppmv - 420 ppmv) co₂ = 580 ppmv co₂
r 20° / 1 atm = 24 ℓ/mol
1 kg co₂ / day / 人 = 11.6 mg co₂ / s / 人
30 人 · 11.6 mg co₂ / s / 人 / (44 g co₂/mol co₂) = 7.9 mmol co₂ / s (a classroom)
7.9 mmol co₂ / s · 24 ℓ/mol = 0.19 ℓ co₂ / s
0.19 ℓ co₂ / s / 580 ppmv co₂ = 330 ℓ / s (of air)
in medieval units that's about 700 'cfm'
if the classroom has 10 m² of open windows you're fine, even an undetectable draft of 0.03 m/s is sufficient, but if it has 1 m² you need a barely detectable breeze of 0.3 m/s, if it has 0.1 m² you need a pretty noticeable breeze of 3 m/s ('light breeze' on the beaufort scale), and if it has a little 100-mm-square register you need 30 m/s which is a 'violent storm' on the beaufort scale (above 'whole gale')
at 'fresh breeze' (8–11 m/s) you need 300–400 cm² of window
well designed ventilation systems can provide this kind of airflow while controlling the temperature and humidity but they are at a big disadvantage because 300–400 cm² of window is a lot smaller than 300–400 cm² of duct
sometimes that's not what matters most tho
We had some employees complain about feeling "stuffy" when air conditioning was turned off(due to budget constraints).
So maintenance brought their own CO2 meter and I brought my trusty Aranet4.
Both our readings were around 650 in a medium sized office with 4 people. Apparently the raise of temperature from 22C to 26C was enough to trigger internal "stuffiness".
PS By comparison my bedroom regularly reaches 3000 in the mornings if no windows are left open.
As I understand it, these sensors require (sometimes lengthy) calibration to remain accurate.
For automatic calibration, the device needs to be in fresh air for 30 minutes, no closer than 1 meter from the nearest person. There is also a manual calibration method. I don't know how often calibration is necessary, but I also think this use case may not be what the sensor was designed to do.
I bought the Aranet4 because it claims not to need recalibration except in exceptional circumstances. They suggest keeping the factory calibration unless you can guarantee a proper controlled environment. I don't have the equipment to test their claims, but the readings have stayed plausible for months with no calibration.
Edit: Note that if you're using your CO2 sensor as a proxy for the rate at which the air in an occupied room is replaced with fresh air the calibration imprecision doesn't matter. You're probably eyeballing the second derivative over the course of minutes-to-hours.
I use my CO2 sensor for that, but I also care about the absolute. There's some evidence that normal rates of CO2 in modern buildings make your brain foggy. I'm trying to figure out if a program better when I use various interventions to increase fresh air.
I've used a barometer on a plane before. When they turn on the pressurization system, it's very clearly noticeable, but not a huge change. (A train in a tunnel is worse.) I'd expect this would be a similar effect.
This often happens in non ventilated and relatively air tight rooms.
We collect air quality data from many schools and see this happening in some classrooms that even over the unoccupied time during the night the CO2 will not reach ambient levels the next morning.
"If a drift of the CO2 measurements occurs, calibration feature of the device should be used. Auto calibration mode is utilizing ABC algorithm whereas Manual calibration mode demands sensor to be exposed to fresh air."
"CO2 sensor of the device is calibrated at standard atmospheric pressure. CO2 readings are pressure compensated and comply with the specifications down to 750 hPa. If the device has to be used at high altitude for a prolonged period of time, manual calibration of the unit should be performed for optimal performance. It is not intended to use the device higher than 4000 m (13 000 ft) above the sea level."
https://cdn.bfldr.com/FS48XT6B/at/k9b9wjnv8f455crkp7846j/Ara...
The Aranet 4 uses the Senseair Sunrise that is more resistant to vibrations.
However I could imagine that sudden air pressure changes could have an impact on the measurement accuracy.
So if the op set a static pressure I assume that would affect the readings a lot.
Calibration is also just the sensor looking for the co2 floor (ie the lowest level possible). You need to do this weekly or monthly maybe..?
Auto calibration just sets the lowest level it has recently seen as the floor.
I am asking because we maintain an open source / open hardware indoor air quality project [1] that we continuously update and I am interested to learn about missing features we might have.
Did your build have a dedicated pressure sensor?
Besides just the ideal gas law in a nonideal world.
Let's assume a perfect instrument.
With a sensor for a target gas for instance that puts out 0 to 10 volts over a range of 0 to 10000 reference ppm, if the response over that range were perfectly linear, and all replacement sensors perfectly identical, then no mathematical device correction would need to be made. This is the most fundamental analog heart of the device.
So what is calibration? It compensates for imperfection.
Based on a detector (sensor) which is sensitive to the number of molecules it is exposed to at the time, this number of molecules will be mathematically converted to a concentration level in PPM, in the case of gas phase that is PPM by volume. IOW for every million molecules you breath in, how many are CO2?
Counting molecules are us.
If you used an analog dial meter to show you the real-time votage output from the sensor, all you had to do was remember that 1 volt equals 1000 PPM, and you know when the needle points to 0.400 volts that means it's 400 PPM. At this point you still have a completely analog instrument. The analog circuitry is doing the math for you, and the math is very simple because the device is so perfect.
Even the dial-indicating voltmeter is perfect, otherwise there would be a need for it's own mechanical correction like turning the little screw(s) to adjust the needle.
When you replace the analog voltmeter with a digital voltmeter instead, it's still the same analog instrument at the heart, so no difference yet except you can probably read 0.400 volts more repeatably on the numerical display rather than the analog dial. Unless you had a very large diameter dial. And you would still need the voltmeter itself calibrated to make sure the numbers were true voltage otherwise the PPM shown would not be right. This can be a little more complex, and more subject to error, than turning a little screw on an analog meter but it accomplishes the same thing. Digital voltmeters usually had more than just one screw to adjust. And many more (cheap) electronic components inside subject to drift compared to the few mechanical changes capable of occurring over time in the analog meter.
So digital voltmeters themselves can be very flexible in their features, often analog meters would simply have a custom-printed scale to readout directly in desired units.
Either way with a perfect voltmeter the perfect sensor still isn't good enough simply because of the task at hand.
When the air is thinner for any reason whether due to temperature or pressure (altitude), there will naturally be fewer molecules of CO2 detected by the sensor even though it's the exact same reference air sample with the exact same PPM. But the meter would then show an unrealistically low reading.
So in order for it to be "reference PPM", you would calibrate under "standard conditions" of temperature & pressure.
Then as conditions change across the working ranges of temperature & pressure, compensations need to be made so the recorded value remains realistic in PPM.
The basic equation is PV = nRT where the pressure times the volume equals the number of molecules times a constant times the temperature. The pressure is relative to absolute vacuum and the temperature relative to absolute zero.
With our perfect voltage output we have turned the voltage into a unitless number which we can directly interpret in PPM. And for gases PPM is n/V, or molecules per (million molecule) volume.
Rearranging to P/RT = n/V, we see that for n/V to remain constant, P/RT must remain unity as P & T change, since R is a constant.
We already knew intuitively that pressure & temperature are inversely related, so the simply perfect analog instrument operator could simply make a few calculations from their voltmeter reading, depending on the temperature in their lab and the barometric reading on their barometer. Then they could always record the the real CO2 concentration even though the meter reading was only perfect under standard conditions.
A more advanced analog instrument would instead self-correct its voltmeter readings so when each part of the instrument is fully calibrated, it always showed true PPM regardless of temperature or pressure changes. By adding a temperature and pressure sensor to the circuit the operator would no longer need to take their own T & P readings in the lab. The voltages (according to their slopes) from these additional sensors would then affect the main gas sensor voltage to result in the corrected reading. In a less-than-perfect world each of these sensors also need their own calibration to known reference values under ideal conditions, and to compensate for the variability of electrical component performance of not just the sensors themselves. So there would be a number of variable resistor calibration adjustments on the circuit board, some being knobs on a control panel, others miniature setscrews inside for factory adjustment not routinely needed.
Alternatively without a controlled environment for calibration, at least use well documented ambient temperature and pressure. Calculated compensations then are not based degrees F or C, nor PSIG, instead you use absolute temperature in degrees K, and pressure in PSIA. These are the mathematical variables that can be completely eliminated from the equation if the actual "standard" controlled environment is available.
And that's for the analog instrument to do all the math itself.
These same 3 analog sensors (and voltmeter) with all their component variability and interactive imperfections can have all this support circuitry to allow full (sometimes tedious) analog calibration like this, or forget about having any analog circuitry doing any math and just convert each sensor's raw analog output to digital and have software do the math (and calibration) and display from there.
This moves the tediousness to the data system electronics instead of the instrument electronics.
Or anything in between these two extremes.
Regardless, you only get results as good as your dedication to the electronic tediousness, you just have to put it in the right place either way.
A human exhales about 1 kg of CO2 in a day (24 hours). That is about 270 grams of C. You'd need enough plants to sequester 270 grams of carbon, or about 0.5 kg of biomass (dry weight) per day, to "keep up" with your exhaling. This is much more than one houseplant.
rosemary is about 50% water [citation needed] and most of the dry part is carbohydrate, (ch₂o)ₙ, which should weigh [edited] 68% as much than the co₂, so roughly each kg of co₂ becomes 1.4 kg of rosemary
a doubling time of 66 days is about 1.05% growth per day, so you need about 130 kg of rosemary bush in your office to grow 1.4 kg per day and thus keep up with your exhaling
except actually it only needs to grow 1.4 kg per day during the daytime, not at night when it isn't photosynthesizing, so maybe you could get by with 90 kg of rosemary bush or so
and probably about half a tonne of soil, say about 2 m²
could be a single plant but it's kind of a tree-sized plant
if you need it to suck up your co₂ at night you need a crassulacean acid metabolism (cam) plant like aloe, but i think you need a larger amount of it because cam plants tend to grow slower. maybe moringa but i don't know if it's obligate cam or facultative cam
[edited to correct calculation erorr]
concrete carbonatation was eating the oxygen in biosphere 2
Which would be massive, and look absurd indoors.
Though maybe that's not a problem, since you shouldn't have anyone over who might laugh at and embarrass you over it - it'd then be only half as big as it needs to be!
might harbor moths tho
edible tho, like moringa
This is the WHO review that summarized the existing evidence for masks at the start of the pandemic. There were 4 studies on n95 masks in hospitals:
https://www.thelancet.com/journals/lancet/article/PIIS0140-6...
Additionally, this is the most comprehensive review of mask literature I am aware of. It explicitly states that:
> At least ten studies evaluate the clinical efficacy of different types of masks compared to one another, but without a no-mask control group most provide little insight into mask efficacy.
> Four RCTs, four meta-analyses, and one prospective cohort study found surgical masks were non-inferior to N95s for protection against respiratory infections, and one found evidence that N95s provide greater protection than medical masks against self-reported clinical respiratory illness but not ILI. However, a recent review found that evidence that N95s protect healthcare workers from clinical respiratory infections at all is “low quality". One meta-analysis of particular note, an April 2020 preprint of a Cochrane review of clinical evidence for both surgical and N95 masks, “did not find any differences in the clinical effectiveness of either type of mask in the setting of respiratory viral infection transmission to healthcare workers,” although the review’s final November version omitted this language.
https://www.cato.org/sites/cato.org/files/2021-11/working-pa...
We simply don't know if n95 masks provide any protection -- personal or otherwise -- in the real world. That is the only honest answer to the parent's question. Everyone who claims otherwise is extrapolating from laboratory experiments, low-quality observational data, or (this is probably the most common) hearsay.
For example, one lasting over 1.5 years was done in the province of Ontario, Canada, involving approximately 15,000,000 participants, in environments ranging from dense urban settings to sparse rural ones. In Ontario's largest and densest population center, Toronto, the duration this study was about 2 years in length.
It was conclusively demonstrated that widespread public masking does not prevent infection, and it does not prevent transmission, of airborne viruses.
It was conclusively proven that such masking did cause accessibility problems, it did cause significant social disruption, and it did cause environmental damage, among numerous other harmful effects.
If masks don't work then why do surgeons wear them?
The best indication is feeling sleepy. Once you become sleepy go outside and take deep breaths, then you understand the sensation difference between O2 and CO2.
In my case my face, specifically my forehead, feels warm. Not to the touch, but more to the nerves. I think it may be different for different people.
Unfortunately that doesn't seem to work for me.
Right now my room has > 1200ppm CO2 (due to closed
doors/windows) but I don't feel sleepy at all
It's a very gradual difference. If you're doing something interesting at 1000-2000ppm you probably won't feel sleepy, but it will probably be harder to focus on something you don't find stimulating and you'll be more inclined to feel sleepy.I think some people are more sensitive to it than others.
Has anyone here managed to? If so, do you have
any tips on how (or whether!) to do this
I have, basically.The easiest (only?) way to do this is simply to have a CO2 sensor, and pay attention to it. You'll quickly learn to intuitively correlate what you're seeing on the sensor with what you're experiencing. After a while you'll be able to vaguely approximate the CO2 levels without even looking at the sensor.
Of course, you won't be able to pinpoint an exact CO2 level, but you'll be able to tell when it's e.g. > 1000.
You've already been doing this your whole life, of course. You've already been distinguishing between "fresh" and "stuffy" air. "Stuffy" air is just our colloquial term for air with undesirably high CO2.
The “my lungs are burning and I must breath” signal is actually caused by high co2. We can’t perceive blood oxygen levels at all.
This is actually something hospitals have to be aware of. A tiny sliver of the population (1-10000, maybe) have greatly reduced sensation of co2, so can literally stop breathing (while awake!) if placed on high flow 100% oxygen.
Don't you think those 'experience correlations'
are based on proxy parameters?
Oh absolutely, I'm sure that's a huge portion of it. Nonetheless, I'm much more attuned to it now.Situations with high CO2 are usually situations with lots of warm, stagnant, exhaled air in rooms filled with people.
Would I be able to detect high CO2 levels in an environment with cool, well-circulated air? I'm not sure. Certainly not as well, and perhaps not at all.
In practice, it probably doesn't matter. I don't think there are many of those pathologically counterintuitive CO2 situations. If the air seems stuffy or stagnant then you can be fairly certain it's full of CO2 and/or airborne pathogens.
With respect to "stuffy" vs. "fresh" air, I don't know whether my sense of it is the same as others'. What I would call "stuffy" is probably affected by humidity, dust, odors, plants, etc. and not just CO2.
With respect to "stuffy" vs. "fresh" air, I
don't know whether my sense of it is the same
as others'. What I would call "stuffy" is
probably affected by humidity, dust, odors,
plants, etc. and not just CO2.
That's fair. I'm not sure if I'm really sensing CO2 levels, or if I'm wholly reliant on those proxy factors that you mentioned.I know that when my wife turns on the gas oven downstairs I can definitely feel a difference even if I wasn't aware she was turning it on and the CO2 meter confirms the CO2 spike. But even then, maybe I'm just "sensing" it via proxy factors like smell.
In practice it probably doesn't matter all that much. Those proxy factors are really good proxies. It's hard to think of real-world scenarios where they wouldn't be.
[1] https://events19.linuxfoundation.org/events/kvm-forum-2019/a...
[2] https://locations.filmfrance.net/location/lyon-convention-ce...
There are some other situations where non-"stuffy" air might have too much CO2, I guess. I guess you could pump CO2 into a room with cool, dry air.
But barring a contrived situation like that, stuffy=CO2.
Before I got a CO2 meter, I could always tell within hours when my building's flaky central ventilation fan had failed because I simply felt something was off.
Unless you are similarly cursed/blessed, just get a CO2 meter. I could not imagine learning this, it is like learning to feel temperature.
I don't know the author's background, but I really hate that otherwise normal people have been reduced to such measures. The advice to return to normal is good. 2.5 years of lockdown were mostly wasted - sorry, enjoy the resulting recession.
If you are healthy, COVID is just a nasty flu. Take a few days off work, and go back knowing that your natural immunity will serve you well going forwards.
One thing that doesn't appear to be addressed is that CO2 is a rough measure for potential exposure, but indoors the air circulation flow is really important. You want the air to take the longest possible path from another person before it meets you. Better yet through a filter, even better it never meets you at all.
So, sorry if you read that as a complaint. But it was a feeling for how I think the world is reacting now. Not that it's necessarily bad -- as I think that after returning to normal levels of travel and in-person conversations, it's very clear to me that there was no good virtual alternative hallway conversations. That being said, it also feels like many meetings could be held virtually when there wasn't much need of true in-person interactions. However, to put one case in point: I had a fantastic trip to IETF-115 and much of that was likely because I was on-site. I'm glad I went.
What you are doing is an optimization problem: you want to reduce your risk of getting infected while restricting yourself as few as possible. How restricting you find measures and how much you want to prevent getting infected is a very personal thing. I will wear masks while shopping and in public transportation, but I still go to restaurants (without masks). Other people will find masks too insufferable.
Hand hygiene and air hygiene for new buildings should be a no-brainer though.
No doubt, but for the majority it is recoverable.
> You’re well advised to train your immune system before encountering the first time with vaccination.
I believe that it's effectiveness is greatly reduced now. The available vaccine was for the alpha variant. From what I remember reading, it essentially no longer reduces the probability of you getting COVID at all, meaning your immune system is essentially unprepared (and hence can't defend against it).
> It also makes sense to reduce the dangers of infection (not just of Covid), [..]
Somewhat, but then you never end up building natural immunity to anything. You have those isolated tribes that would likely get killed off by the common cold if it was ever introduced to them.
> How restricting you find measures and how much you want to prevent getting infected is a very personal thing.
It is a personal thing, but it was also an idea inflicted on people. This was not generally well practised before, nor does it particularly have any benefit done in small (read one) isolated pockets. I believe we have all now seen people who are many-times vaccinated, wear multiples masks, avoid any contact with people, and yet are otherwise perfectly healthy.
> Hand hygiene and air hygiene for new buildings should be a no-brainer though.
Even prior to COVID, I wish more consideration was put in place for air quality. Bin the ionizers and get decent filters in place that reduce carbon dioxide filters.
I think it would be interesting to see if there's any correlation between restful sleep and CO2 levels too. Maybe change the CO2 level to higher to induce sleep, and then fall asleep, and then bring it back down to have a nicer sleep.
It doesn't have to be so complex. It could be as simple as a little canister that you simply take up, open in the bedroom, and empties itself (for a room of a given m³), then turn ventilation on low and go to sleep. The CO2 level would spike to the target level in a minute or so (presumably not a dangerous level, just one that makes you temporarily less smart and attentive) and then has some half life depending on your ventilation method.
I'm not a doctor, I have no idea if it's smart to raise the level to 3, 4, idk how many thousand ppm are being proposed for this, even if it's for only 30 minutes or whatever. Just saying, I don't see obstacles to doing this safely if the action itself is safe.
carbonated drinks are carbonated to about 4 volumes so you could get 6 3-liter bottles of soda water and open them in your bedroom, releasing 72 ℓ of co₂ over the next, probably, half hour
normal levels of ventilation for inhabited spaces are several air changes per hour, like 3–10, so this wouldn't raise your co₂ levels much unless the ventilation was super low
i also don't know if this is a safe thing to do but i don't see any obvious dangers. you can't accidentally put twice as much co₂ in a bottle of soda water and iirc the idlh is like 30000 ppm
I wonder if sleepiness is some sort of evolutionary reflex or actually caused by co2 in body.
Instead of the room, maybe a little device called blanket could be used, but I don't know how reliably people get out from under that if they get in the habit of associating under blanket = sleep = good, because it certainly wouldn't be good to be under that all night.
Yes, the air quality on London buses is consistently terrible on cold days. There is very little ventilation in those buses other than "open the windows", and when it gets cold people don't do that. Often it seems like you're not only breathing in everyone else's food smells and stinky breath, but road fumes and dust as well.
"Researchers found that a person travelling on a bus for two and a half hours was exposed to a third of what they would be travelling on the Tube for just an hour." https://www.independent.co.uk/news/uk/home-news/air-pollutio...
EDIT: Regarding CO2 levels, there's a 2018 FOI request which seems to imply it wasn't monitored back then, but was within regulatory limits though I'm not sure I'd want to travel on the tube more often than necessary?
"The regulatory limits for CO2 are 5000 parts per million (ppm) for 8 hours time weighted equivalent or a short term exposure limit (15 minutes) of 15000ppm." https://tfl.gov.uk/corporate/transparency/freedom-of-informa...
The air certainly smells and feels a lot fresher and healthier on the extensively-ventilated Tube compared to on crowded buses with little or no ventilation at all.
https://eu.usatoday.com/story/news/world/2017/04/10/london-t...
https://www.london.gov.uk/press-releases/mayoral/londons-tox...
https://www.unep.org/news-and-stories/press-release/revealed...
There are also several other ways to get the output such as a bleak project on GitHub (https://github.com/Anrijs/Aranet4-Python).
One: that even if the C02 seems fine, if the din of the room means everyone is shouting then viral dispersal
will be much higher.
Two: it seems like having fresher air, will be more costly in the winter unless people can put up with lower temperature.
I wonder how effective an airplane filter really is with regard to viruses.
Should buildings and enclosed spaces be redesigned to include better filtering and at what running cost will that be?
Airplanes are far better than any normal indoor building space. It’s a constant blend of outside air that means the entire cabin’s volume of air is gone within something like 5 mins.
But only when they fly. When you are waiting that 30 minutes sitting in the plane after boarding, the fraction of re-breathed air can get high. People have measured 2000 and 4000 ppm CO2 readings.
As in it never dips below 1200pm on either the short haul or long haul flight.
Also with the caveat in the article: "Note that the graphs below aren't calculated for altitude adjustment. Since planes are generally pressurized to an equivalent of 8000 feet, and senor drift is typically 3 per 1000 feet of elevation, it means that while in the air the CO2 levels are likely $24% higher than shown on the graph."
It seems the logged numbers are underestimating it.
https://en.wikipedia.org/wiki/Energy_recovery_ventilation
https://techxplore.com/news/2020-12-ventilation-easy-highly-...
https://hackaday.com/2022/07/07/the-benefits-of-displacement...
But that's not exactly easy or cheap. And dangerous when done wrong.
I'm OK with not easy, not cheap, dangerous, and done wrong.
That's what I want.
When were you born and where did you get that number from?
but it's nontrivial
whitewash curing (lime carbonatation) is the easiest process and the one most used in scuba, anesthesia, and hyperbaric chambers; though it's less energy efficient and involves higher temperatures than amine scrubbers, you can hopefully outsource that part of the process to something outside your house
the overall reaction is
cao + co₂ → caco₃
caco₃ is 44% co₂ by weight so each kg of co₂ you remove from the air consumes 1.27 kg of quicklime and creates 2.27 kg of chalk
with only water as a catalyst this typically takes about three months; without even water it takes about three years. as i understand it, with a few percent of lye as a catalyst it can be complete in under a second, which is how soda-lime cartridges for scuba rebreathers work
suppose your house is sealed except for 100 ℓ/s ventilation (212 cfm in medieval units). you're going to be exhaling into it, so maybe you want to reduce the co₂ content from 420 ppm (duude) to 250 ppm, 40%, so you run 40% of the air through a lime scrubber, 40 ℓ/s, which outputs effectively co₂-free air
this intake scrubber has to soak up 17 mℓ co₂ per second (420 ppmv of 40 ℓ/s); at 1 atm and 20°, pv/rt gives us 7.1 millimoles per second, which turns out to be 31 mg of co₂ per second, about 2.7 kg co₂ per day, consuming 3.4 kg per day of quicklime and producing 6.1 kg per day of chalk
if you're doing this without an alkali catalyst you probably need about 300–400 kg of slaked lime (whitewash or whatever) exposed to air. if we roughly estimate that as 200 ℓ at a 1-mm-thick paint layer it's 200 m² of freshly whitewashed walls. this will probably occupy a cubic meter or two in your house. soda-lime is probably a better option
either way you're left with about 190 kg per month of chalk waste (maybe with sodium carbonate in it) that you need to dispose of and replace with a bit over 100 kg per month of quicklime. you could conceivably handle this yourself by burning it in a lime kiln yourself a couple of times a year, but a more pragmatic approach might be to buy four 25-kg bags of quicklime every month (about US$150) or a one-tonne pallet every 10 months. a tonne of quicklime exposed to the atmosphere will probably absorb about a kg of co₂ per day even without water
you can reduce this a little by reducing the flow rate but pretty soon your own co₂ breath starts to build up in the space, especially if you're getting jiggy with your husband in bed
if instead of scrubbing your intake air you try to hermetically seal your house like a submarine you only need to remove 1 kg co₂ per day (per person) but you have some new problems
one is that by removing 1 kg of co₂ per day from the air you are effectively removing [edited] 0.73 kg of oxygen from the air per day, so your oxygen concentration will fall. when it falls by 50000 ppm (50 times through the filter) it starts to become a serious problem. you can do things to replace the oxygen but you can't detect this problem at all without oxygen sensors and it can cause you to fall asleep and never wake up
the other is that, with such a sealed life-support system, co₂ is far from the only gas you need to actively manage. water vapor, h₂s from farts, methane from belches, mercaptans from bad breath, and butyric acid from your gym socks all require attention. the life support systems on the iss are publicly documented and i recommend reading the reports to see how they deal with these issues
on the other hand you won't be breathing diesel smoke from the semis passing by and you'll be totally set if there's a poison gas attack
see also https://news.ycombinator.com/item?id=33579810 for the scale required to do this with a greenhouse instead of a lime scrubber, but if you garden you know that's also nontrivial
I've got the window closed, I have a few houseplants, and I am already considering getting rid of Mr. Tiddlesworth, my cat.
Is there some sort of machine I can buy? Like direct air capture?
I only need this in like two rooms of the house.
That’s in the middle of the Pacific Ocean.
I guess you could try to live in a place where the plants are photosynthesizing vigorously.
I tried PurpleAir, which seemed to be quite good in this regard; but then you read reviews and tests that compare multiple sensors in the same room, and you don't know what to believe.
https://www.newsweek.com/carbon-dioxide-levels-flight-deck-a...
Also, my measurements were different from author. On a plane co2 was pretty bad until AC was turned on (usually around midway boarding), then it hovered around 1000ppm. On a train it also stayed around 1000ppm.
Instructions and code at https://github.com/pmarks-net/exhale
787 maintain internal air pressure equivalent to 6,000 feet of elevation. All other commercial aircraft maintain 8,000 feet air pressure. I think most of my discomfort from long flights is due to altitude sickness. The only time I have slept on a long flight and awakened refreshed was on a 787.
Jet engines use a neuro-toxic lubricant. Occasionally, some of this enters the cabin through the compressed air feed and poisons the passengers [1]. 787 passengers don't have this risk because the planes don't draw air from engines.
[0] https://en.wikipedia.org/wiki/Boeing_787_Dreamliner#Interior
CO2 rises in the cabin during taxi because the bleed air system is not effective while the aircraft is moving slowly. This is another good feature of the 787: cabin air conditioning works adequately even with the aircraft at rest.
Presumably the external air mix is just full of exhaust before they're at speed.
The immediate impact was that I became super nerdy about air quality, specifically CO2. It was indeed super high in that house; opening the window helped, but it led to me moving to a place with much better air quality in general. Nature in view, lots of green plants, and an HRV system. I can get <600ppm with the windows closed.
TL;DR: if you ponder complex things for a living, you owe it to yourself to get nerdy about CO2 in your sleep and workspaces.
It's actually a "CASEMATIX Portable Credit Card Reader Case Compatible with Square Contactless and Chip Reader, Case Only", which was the best possibility I could find. It would be nice if someone would make a dedicated case for the aranet4 as it is fairly sensitive. I'm fairly happy with this cheap case, but I'd like something that was better fit and designed for air intake, eg.
"We're incredibly proud to have our CO2 sensor Senseair Sunrise inside this popular product."
The sensor itself costs $229.00 at co2meter.com.
[who just found this discussion of my article... which started long before I finished even getting all the data on the page]
Lose the mask and hire a therapist.
On one hand, masks are pretty effective at blocking pathogens. But on the other, as the rest of the population gets infected around you, your exposure to things you haven't yet seen will get really high, so it might turn out that wearing a mask 24*7 just delays your inevitable infection by a few days or weeks.
The covid tangent is largely bullshit. You will get it regardless of what precausiosn you take.
The point is that in a large number of venues we have CO2 levels that are actively detrimental to your ability to think. This is a problem that we need better ventilation to solve. That bedrooms had the poorest air quality is something I wasn't expecting and will likely buy my own sensor to measure.
So either quit your job or learn about staying healthy when exposed to viruses that deplete zinc and other nutrients.
Zinc deficiency lowers Tertrahydrobiopterin, which lowers coupled NOS, which lowers your immune system (NOS2) and gives you hypertension (NOS3) and makes you mental (NOS1). The Lower zinc also gives you diabetes. PubMed links for anyone who cares, but you probably don't.
Before taking Zinc get your Serum Zinc and RBC Zinc levels tested. Easy to do in the US if you have some money.
Also get your Serum Copper and Ceruloplasmin tested since taking zinc at high dose for a while will lower copper since zinc creates Metallothioneins that capture the copper in the intestine before it can be absorbed.
--
Hey, thanks for being curious! Science!
Zinc and Tetrahydrobipoterin:
https://pubmed.ncbi.nlm.nih.gov/31732151/
The Gene GCH1 is central to making Tetrahydrobiopterin and uses zinc as a cofactor.
https://www.uniprot.org/uniprotkb/P30793/entry
The zinc coupling of NOS via GCH1:
https://www.ahajournals.org/cms/asset/2cc8b7a0-a31a-4759-bc8...
Uncoupled NOS makes a lot of superoxides, BAD!:
https://www.liebertpub.com/cms/10.1089/ars.2013.5566/asset/i...
Here is a diagram of all the enzymes that need Tetrahydroibiopterin (BH4):
https://www.researchgate.net/figure/Metabolic-pathway-of-BH4...
NOS2 and the immune system:
https://pubmed.ncbi.nlm.nih.gov/24477906/
https://www.jimmunol.org/content/167/5/3000
COVID and NOS2:
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754882/
Zinc and hypertension:
https://pubmed.ncbi.nlm.nih.gov/32090294/
NOS3 uncoupling and hypertension:
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4816601/
NOS1 and psychosis:
https://pubmed.ncbi.nlm.nih.gov/12140778/
Zinc and Diabetes:
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6984028/
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3407731/
And the BIG one, Zinc and Heart Arrhythmia, you know the thing that all these your people are suddenly dying with? https://publichealth.jhu.edu/2022/covid-and-the-heart-it-spa...
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7328074/
You know, they are avoiding looking at zinc, purposefully, and I feel it is a crime against humanity. Seriously.