by Maxburn · 3y ago · 0 comments
Commercial buildings have all sorts of rules under Ashrae in the US. Generally in commercial there is a minimum air exchange rate for occupied space. Pre covid it was being constricted for "green" energy initiatives in the name of energy and $$ savings. That restriction was allowed to be really clamped down on (more savings) if certain conditions were met like CO2 monitoring or people counters, both more tightly targeting how much fresh air people actually need and minimizing waste in conditioning outside air that isn't necessary. Post covid a lot of that got thrown out, commercial buildings are now generally over shooting OA exchange in the name of not turning these spaces into germ breeding grounds.
None of this really exists in the residential sector, but maybe it should. Homes in even the recent past are "leaky" enough to get enough outside air exchange for the low occupancy rates without actively conditioning and bringing in outside air. Some modern energy efficient homes that are wrapped and sealed extremely well might pose an issue to this.
By all means get a decent sensor that reads CO2, CO, PM1, PM2.5, and VOC. Radon if you are in a risk area. Your regular thermostat probably already gets you temp and humidity. It needs to have some way to do long term data logging, five or ten minute sample rate for a year for example. You really want to see how things are different across seasons.
With that data in hand there are plenty of things you can do if you need to introduce more OA to occupied spaces. Generally there are heat exchangers that can be dedicated to that sort of thing. Or a simple motorized damper opening up a small filtered OA duct on the intake side of the air handling unit. Ideally those devices would only be activated on unacceptably high bad air quality readings.
The requirements exist in the IRC [1] but are frequently not enforced in many jurisdictions.
[1]: https://www.energyvanguard.com/blog/2018-building-code-makes...
Green Building Advisor (https://www.greenbuildingadvisor.com) is a great community for such things, with a 99% residential focus.
I have an ERV in my house, running continuously. There are some great pieces of equipment out there, but they require conscious consumers and/or progressive code enforcement to end up in use.
Aside from the smell of beer, it was like stepping out into the Swiss Alps. I've never understood why rich people will spend $40K on audiophile equipment yet put up with crappy phones; I did a BBC interview remote in their NY studio using a $10K mic and the difference was staggering. Here, I swore if I ever got rich I'd want good indoor air.
It turns out I can afford to redo my house in California with a heat exchanger. I'm certain the hardest part will be finding a contractor who will exceed standards. Standards are why I have 1/2" pipes under my house. I want the bleeding edge of what's possible in my lifetime.
I can only recommend you do the homework and tell them exactly what you want installed. ie; be your own specification engineer. Anyone that's actually good at this sort of work goes commercial exclusively, that's where the money is.
You're saying, same drill here.
The weird thing is it seems to mostly spike at night time and even more so on the weekends.
I have a few hypothesis, such as: - furniture offgassing - us being in the bedroom - gas cooking in the apartment building somehow settling into our ground floor apartment at night? - it seems to be worse if we have the aircon on - it really only seems to properly dissapate when the windows are open and theres good breeze and there seems to be a correlation between that and the sun coming up?
Like bisecting code, you can bisect airflow with plastic (e.g. 6 mil polyethylene) sheeting. Move the VOC sensor between isolated zones, or use multiple VOC sensor logs to track dispersal time/direction, narrowing down potential sources.
> it seems to be worse if we have the aircon on
Central or window aircon? You could place a VOC sensor near the HVAC duct input.
If I install a meter and find CO2 is high, do the Ashrae guidelines give me any leverage against the building management?
Already it's often too hot because I'm on the top floor and I think they run the heat for the people on the bottom floor who are cold and the HVAC system doesn't seem to be able to deal with this.
Zoned systems are supposed to be able to handle individual zone heating/cooling issues, floor to floor without question should be able to be controlled. Entirely depends on what is installed and how it is controlled. This is an area where cost cutting happens. Generally there's a ashrae spec saying there is a minimum of five degrees °F between heating and cooling.
So sure get a couple data loggers and report any findings to your manager.
I think it has become clear that germ loads can be reduced significantly with filtering and ventilation.