by micro_cam · 3y ago · 0 comments
And it provided ac in the summer which we didn't have previously.
There are some downsides, it was expensive to put in and the outdoor unit is loud. While it does save us money, it probably wouldn't make sense as something that will pay for itself in heating costs with current propane prices and natural gas is much cheaper if you can get it. But definitely makes sense for new construction especially when paired with a wood or propane stove for back up heat in power outages/ambiance/quick heating.
This will turn the noise into a slight murmur.
Americans on this site always mention grid failures as a concern about electric heating/cars/whatever.
While I won’t claim that power failures never happen where I live, because they do…but they’re very very rare and short enough not to care. The only exceptions are major natural disasters like hurricanes.
Americans, why do you have such a terrible electricity distribution grid?
Anyway, where I live in Boise most utility outages are due to physical damage - whether that be animals, auto accidents, extreme weather (not “it got cold”, but wind gusts toppled a tree that brought down a utility pole), and fiber seeking backhoes. Even had the gas get shut off at my old house because an auto accident hit some equipment a street down causing a gas leak.
I will compare a nominal 3Ton = 36,000 BTU/h (10.55kW) furnace+AC running at about 1200CFM with gas fuel input at 45,000 BTU/h to similar heat pump system outputs and electric resistance heat.
The central furnace fan is probably about 1/2 horsepower rating (372W) and has some design tolerance built in where the brake horsepower is less than this. The heating output at 80% efficiency is 36,000 BTU/h (10.55kW). This output is constant regardless of outside temperature. This could be run with a small inverter generator or possibly a robust battery system in the 20kWh range with appropriate solar.
Note that the heating input for this size of furnace can go up to ~155,000 BTU/h (45.4kW) with only the same amount of fan power needed in the form of electricity.
Looking through Mitsubishi literature, a 3ton hyper heat pump (SUZ-KA36NAHZ) at 17f can deliver 25400 BTU/h (7439 W) of heat output with an input of 2490 W. You will need strip heat to supplement this output to make up the difference (10.55kW - 7.439kW = 3.1kW of electric heat) So total power input is 3.1kW + 2.49kW = 5.6kW input for 10.55kW output. This might be short a few hundred watts as you still have to run the fan. This could be done with a larger portable generator.
http://mylinkdrive.com/USA/M_Series/R410A_Systems-1/Outdoor_...
Electric resistance heat would need the full 10,550 W to equal the output and now you need a relatively large fixed natural gas generator and transfer switch.
My personal opinion is that a heat pump system for normal operation with a natural gas or propane furnace as backup emergency heating is a good option to cover emergency situations as much as possible without adding an additional separate system like a wood burning heater or similar device.
I'm sure there are exceptions, but I've never heard of one.
Lots of above ground power lines in heavily forested suburban sprawl means lots of branches in lines every wind storm and they (private) electric co has to visually check all of them before they can turn power back on.
Despite being much more rural the power coop that serves me now seems to never have an outage that lasts more then a few hours. Probally mostly because they have much less pine to check.
Which is the same as with us Americans.
My last apartment had a handful of power outages and all except one was due to weather. The exception was a transformer that exploded — which seems common as I’ve seen at least three just randomly go boom.
When you get major weather events, where they are pulling in personnel from all over the nation, is when people get concerned about electric heating because it might take a while to get to them.
My local utility pays 50 EUR starting 12 hours after the start of an outage, and 4 EUR/hr after that. So a 2 day outage would pay out 200 EUR, and it all happens automatically.
There's no exceptions to this (only if you are at fault...), and this gets subtracted from their regulated revenues such that it hits the bottom line.
Naturally, most low voltage distribution lines are buried under ground
Our neighbourhood had an outage last winter during the -40 cold snap, and we were definitely at risk of water pipes freezing (gas fireplace was on, but without circulation it didn’t matter). The potential structural damage repair costs from outages up here would be insane, which makes me wonder if that’s part of why our grid seems so reliable (compared to other countries, anecdotally).
Recently, I stayed for three months on a mountain in Virginia. We lost power at least 6 times, usually for multiple hours. Once it was out half the day. There's a good reason the proprietor there keeps a backup generator on automatic failover.
My well pump is electric and I haven't been out of power long enough to be concerned about getting water.
It’s very common for branches to break and knock out power lines in the summer during windy storms.
This usually means no power for 1-3 day stretches and only happens 1-3 times per year. So worst case it’s no power for 9 days total every year.
The problem is it usually hits in the hottest days of the year so people really complain — myself included.
WFH also makes matters more complicated.
Very very spread out population.
And huge spikes and troughs of infrastructure investment over decades.
No, wrapping a compressor in a blanket doesn't make it overheat. Compressors are cooled by the refrigerant running through them, not through heat lost through the casing.
[0] https://www.eia.gov/dnav/pet/hist/LeafHandler.ashx?n=PET&s=W...
In the SF Bay Area, our last PG&E bill split across Jan/Feb was effectively $3.05/therm. The actual pricing in our bill reflects tiered pricing, with different tier thresholds in each month. The first tier covers up to 2 therms/day in Jan and 1.48 therms/day in Feb. The price tiers were $2.68..$3.06/therm in Jan and $2.75..$3.14/therm in Feb.
The bill also described $1.37/therm and $1.44/therm procurement prices for Jan and Feb, respectively.
It used to be much cheaper so a lot of old houses that aren't near a natural gas line were built with propane heat. You might save $200-1000 a year by switching to a heatpump but that means 10+ years to offset a ~$10000 install cost for a large unit professionally installed with a new 220 circuit run for it etc so most people just keep paying for propane or maybe use small electric space heaters.
And if you are somewhere you need to worry about pipes freezing in power outage a while you are away or temps bellow the heatpumps minimum -15f range a propane stove is a nice option. Relatively cheap to install and they can be setup to run on a thermostat with no grid power.
If i was building a new house i'd go heatpump + a propane stove for back up heat and a dual fuel induction/propane range.