35 points · by userbinator · 3y ago · 65 comments
Also surprisingly (to me) is if you have a pin that goes into a hole that is 1-2 thousandths of an inch larger than the pin, it feels like a sloppy loose fit. If you want the pin to feel like a really nice smooth fit you need more like a couple TEN THOUSANDTHS of an inch clearance.
Also the auto body guys whose hands are like profilometers [2] and can just feel various surface quality [3]. This is actually where precision originally came from with the 3 plate lap where you're just using fingers and candle soot to create crazy high surface flatness [4].
[1] https://willrich.com/product/starrett-direct-reading-bench-m...
[2] https://en.wikipedia.org/wiki/Profilometer
[3] https://en.wikipedia.org/wiki/Surface_roughness
[4] https://ericweinhoffer.com/blog/2017/7/30/the-whitworth-thre...
He fan feel thousands of inches and can note the individual thickness of each card he touches.
He is also 100% blind, and he talks about how sensitive his touch is.
He is unbelievably remarkable
https://en.wikipedia.org/wiki/Richard_Turner_(magician)
the documentary he is in is called "Dealt"
For the unindoctrinated, this concise Typical Tolerances of Manufacturing Processes reference[1] may be useful towards establishing pragmatic expectations for manual processes.
[1] https://mae.ufl.edu/designlab/Lab%20Assignments/EML2322L-Tol...
Luckily we don’t really do PCB design in imperial anymore at any of the companies I’ve worked with (I hear even US companies are moving away from it since so much of the manufacturing is offshore)
There's at least https://en.wikipedia.org/wiki/Mars_Climate_Orbiter and TBH I was hoping there'd be a link to such a list on that one.
I seriously hope I'm Poe's Law-ing your post too, and there's an implied /s on there, because if you could see the level of communication effort I see at work … yeah, I'd absolutely believe that someone would use it in a confusable context.
Most parts were imperial IIRC until at some point they started selling parts that were too small (smaller than 0201) and switched to metric. I can understand wanting to switch to metric, but reusing the same goddamn size codes is too chaotic for my taste. Come up with different numbers.
You'll still use metric, but you'll just end up seeing lots of 2.54 or 0.254 everywhere.
My unsophisticated wild-ass guess about why they persevere: Like Fahrenheit, it so happens that mils as a scale intuitively correspond to sizes of trace we care about. A 5 mil trace is pretty run of the mill for signals. 20 mils for most IC supply traces. 3 mils is small and expensive to make (last I checked! capabilities have changed rapidly in my decade of experience)
I think the intuition argument is often just a post hoc assumption for things that we are actually just familiar with.
The numbers get even better on the metric system. I was expecting them to just not get much worse, since they were picked on the imperial on.
I guess they are a mouthful without good abbreviations and there was a tech jump between woodworking and machining so in betweens aren't used
I've heard that in some crazy parts of the world - say 95% of the planet - it's base-10 all the way down.
Makes you wonder if they're on to something with that kind of whacky scheme. Hopefully it works out for them.
Guitar strings are, e.g. 9 to 46: .009" high E, .046" low E.
Classic DIP (dual in-line package) integrated circuits and headers have 100 mil spacing: ten pins per inch. IIRC, you drill a 25 mil hole for the pins. This is international.
The metric system doesn't have a nice mil-like unit for those scales; the millimeter is way too crude, and micrometers are too fine.
The mil is just right for all sorts of miniature things that are still large enough to be worked on by human hands and eyes.
This kind of absurd claim would be more compelling if you hadn't just used 3 decimal places and a quotation mark to define a distance in a format used by at most ~5% of all the people working in such scales:
> ... 0.046"
My point - metric can also use decimals. More adroitly, too, I'd argue, because of the consistency.
If you're routing a circuit board, you have a grid that is a multiple of the mil: e.g. 25 mils, so if have a part with 100 mil pin spacing, that is four grid lines. Trace widths are multiples of a mil: 6 mil, 8 mil, ... through holes are mils: 25 mil, 40 mil, ... no decimal point or " mark in sight.
Sure, a tenth of a mm would be a useful unit. Problem is, 0.1 mm has no name. It's either 0.1 mm or 100 microns, which are too small. I've not seen anyone define such a unit in practice; they just plod along with multiples of 0.1.
But that's just a historic accident.
Related, the metric system was forced upon trade in Germany not before the early seventies. Only few units previously used survived, e.g. the 'Pfund' (pound, now redefined as 'half kg'). My father continued to use 'Zoll' (inch) and lamented American made machinery using threads on nuts which differed from those used in Germany (and everywhere else). Even I know the folding carpenter's ruler only as 'Zollstock' (no one says 'Gliedermaßstab').
And while I used to be very opinionated about the imperial- vs. metric system, after twenty years in California, I feel comfortable at 75°Fahrenheit and am exhausted, if I have to walk more than a few miles. I even caught myself recently referring to a width as 'about a yard'...
One reason these whole even numbers are used is because it's easier to inspect with basic tools - ie just fold/layer it a few times and measure the thickness - like using a rule to measure 64 sheets of 1/64" stock and hoping to get 1". The evenness is about doubling/dividing to achieve this effect.
They also had very primitive measures for bore size that worked the same - ie "gauge" for shotguns was the number of how many balls of the barrel's size added up to 1 pound of lead, so you could have a basic scale and infer everything from there.
If a measurement is 3.125 inches, you know that it's 3 inches and 125 mils.
You don't need support for fractional syntax in order to have an input field for inches that goes down to mil precision: just a regular decimal numeric input.
You cannot dismiss the advantage of decimal fractions as casually as you can reject the metric system.
:o
TIL. Thanks for sharing that, this is handy to know.
The US customary units are pretty logical, they're just not powers of 10.
That's how it's used, but the units don't measure the same thing. It's like measuring an engine's power output in square meters, because a kilowatt is about a square meter of sunlight.
It somewhat slides off the cliff when you take into account the existences of the imperial ounce and the US food labelling ounce, though.
i've been doing it for years and i'm still shite at it.