117 points · by ubj · 3y ago · 176 comments
https://wikipedia.org/wiki/Texas_Interconnection#Ties
The Texas Interconnection is tied to the Eastern Interconnection with two DC ties, and has a DC tie and a VFT to non-NERC (North American Electric Reliability Corporation) systems in Mexico. There is one AC tie switch in Dayton, Texas that has been used only once in its history (after Hurricane Ike). On October 13, 2009, the Tres Amigas SuperStation was announced to connect the Eastern, Western and Texas Interconnections via eight 5 GW superconductor links.[1] https://www.ercot.com/files/docs/2020/07/30/ERCOT_DC_Tie_Ope...
[2] http://www.caiso.com/Documents/ISOMaximumResourceAdequacyImp...
[3] https://www.caiso.com/documents/californiaisopeakloadhistory...
[4] https://www.ercot.com/files/docs/2022/07/20/ERCOT%20Monthly%...
Municipal grid gear here isn't rated for the ice burden like utilities in the north east.
It seems to stem from the 2021 ice storm outage, but that wasn't even close to the worst power outages seen in other parts of the US that are part of larger interconnects, so I don't see why it's special other than it's hip to hate on Texas by coastal elites like us.
So, the wind was blowing at a tiny fraction of its installed capacity. Had it been producing at anything near its nameplate capacity then we wouldn't be talking about this now. But of course this isn't entirely unexpected, it was the predicted behavior.
OTOH, the reliable sources of power in TX has been getting squeezed for decades now. Many of them are only making money when the wind stops blowing. The rest of the time they are starving, so its no wonder they cut weatherization efforts (and lots of other things) because it costs money for something which may/may not happen. And you have to pay the NG suppliers to maintain a couple extra orders of magnitude in capacity and storage which sits unused most of the time, which again they didn't do. So the wind didn't blow, and the NG plants and producers simply failed to make up the loss because they didn't have the cash to assure their own reliability.
So, its basically what many people (including myself on this board) have been saying for a long time. What you have now is a game of weather predictions statistics dictating the reliability of the power grid. Its possible to win for years on end, and then boom perfect alignment of the stars and you fall back to non renewable sources which have been underfunded and not built out sufficiently to carry the full grid load. So you can play games with the statistics but solving the problem is an exponential cost problem unless you willing to just go build and maintain 100% of the grid requirements using carbon sources as backup.
Also, that outage knocked out something like 25% of global PVC production for about a year, which interfered with basic infrastructure projects globally. You can’t build modern drainage or plumbing without PVC. Without drainage or plumbing, you can’t build buildings or repair roads.
Also, it was totally predictable, totally avoidable, a bunch of people died as a direct result, and the last N times this happened, they did nothing to fix it.
(Fixing it would involve winterizing their production facilities, which over half the planet has done every year for over a century.)
https://www.texastribune.org/2012/10/25/texas-regulators-act...
This time around they largely just reverted that previous action and returned it to the earlier 2012 proposal (~5k/MHw), and recently have been talking about basically having the state government pay to build NG plants. (although i've not been paying real close attention to where those bills went).
ex: https://www.texastribune.org/2023/04/13/texas-power-natural-...
I'd rather my regulators copied ERCOT than what they are actually doing; I pay a lot for power because of serial gold-plating of infrastructure. Then maybe Australia'd be able to afford to manufacture something in globally significant quantities.
Not "fixing" things can lead to better outcomes for most people.
The other bit of politics is that this is a proxy fight for "can government regulation be good"? Government regulation would have prevented the prices from skyrocketing, but the thesis of Texas is that government regulation is bad.
Now perhaps retail customers shouldn't be allowed to be directly exposed to the wholesale grid prices for their own protection, but it's not like these were people buying a perfectly normal electric plan who then got wacked over the head with a $16k bill.
[0] https://www.facebook.com/GoGriddy/posts/2740589872846248/
Those people purposely signed contracts exposing them to the spot prices. They got exactly what they signed up for. Those people were few overall as well, by the way. Most people are on fixed contracts.
I wonder how people survived freezing weather before HVAC systems.
> Government regulation would have prevented the prices from skyrocketing
The Law of Supply & Demand is always in play, meaning price caps result in shortages. According to your post, shortages mean people will freeze to death.
https://www.texastribune.org/2021/02/18/texas-power-outages-...
It got politicized because it was so difficult for people there to handle it. When other places have power outages, the infrastructure and building designs make living through it much easier.
NPR's podcast: The Disconnect: Power, Politics and the Texas Blackout https://www.npr.org/podcasts/1004840920/the-disconnect-power... ... and the files for that appear to be missing... (if you have Apple Podcasts https://podcasts.apple.com/us/podcast/the-disconnect-power-p... ; Spotify: https://open.spotify.com/show/2l3VBG6RfEGehHm7Y7HfF4 ; Amazon music: https://music.amazon.com/podcasts/5d4dd6d6-bcbd-41a7-b418-7d... ). I especially suggest listening to the episode "The Fallout"
Texas set up an energy market that was to eliminate waste and in doing so set up their grid so that it was constantly almost at load shedding (as that has the least waste).
The problem is there were minutes away from a black start in which Texas would have been without power for an extended period of time - not days but weeks or months (and that the black start generators were also failing).
Practical Engineering:
* What Is A Black Start Of The Power Grid? https://youtu.be/uOSnQM1Zu4w
* What Really Happened During the Texas Power Grid Outage? https://youtu.be/08mwXICY4JM
And that when that happens, given the way that the Texas grid is set up, the rest of the country would be unable to help.
And as that "hip to hate on Texas by costal elites"... utilities were trying to charge Minnesota for the part of the cost of the Texas outage ( https://arstechnica.com/tech-policy/2021/04/houston-based-ut... --- https://minnesotareformer.com/2022/08/11/utility-regulators-... ).
If someone attacked all the interconnects then the net importers would lose power or brown out while the net exporters would be just fine. (assuming the net importers are currently running power generation at capacity).
For the grids under load, if more capacity can't be brought online they'd do rolling blackouts while working to restore the interconnects.
There are far better targets for a coordinated terrorist attack if they wanted a larger impact.
I believe the 2003 blackout was basically a cascading set of load loss faults
The risk of very high altitude "super EMP" nuclear attacks is the most concerning. If Taiwan were attacked, it would stand to reason that China would first create CONUS disasters against infrastructure without a direct, kinetic military attack. This would be most effectively deployed by EMP at very high altitude while simultaneously sabotaging infrastructure with hacking.
https://en.wikipedia.org/wiki/Microgrid
If solar on rooftops (with batteries or EV connections) became really widespread in the US it may make some sense to be able to isolate communities from the rest of the grid to localize failures. Utilities would probably hate it but it could be really resistant to disruption.
When any market gives no incentive for most participants to resolve any supply/demand imbalance, then shortages are sure to happen from time to time.
Electricity isn't even a market where people can 'panic buy' like toilet paper.
So, it is possible to have some force changing consumer behavior. It all depends on sane legislation, allowing a system like this to exist.
But there was always this niggling concern that the price could spike to 200x like it did in Texas, without me being able to react. Regulation to cap the peak rate would help allay consumer fears, IMO, while still offering ample profit potential to providers.
You could adjust the limit as you please, with a default of perhaps $100 - but they spare you from million dollar bills, even with uncapped dynamic pricing.
If a reasonable number of these were deployed, the prices would never spike super high, because there would always be someone else willing to turn off their tumble dryer to save 50 bucks.
People can "panic buy" generators, and have been doing so for a while. With solar panels on the roof for when the sun is available and some alternative source like your generator (cheap to buy, expensive to use) or batteries (expensive to buy, cheap to use) for when it is not and power has failed you can be mostly energy independent.
Gasoline generators are a PITA. Most of them require frequent oil changes. And floating neutral generators generally won't work well with GFI circuits because they easily see an imbalance in current across neutral and to the ground path. If you want your generator to be safe and work with GFI, you'll have to use a bonded one and ground it.
Most residential solar sets in California lack battery backup capacity and do not generate power in the absence of grid power "for safety". This is because most homeowners are uninformed consumers and don't know what options they need. It's worth getting a subpanel, moving critical loads to them, and having a 3-way ATS with solar-batteries-inverter, grid tie, and an autostart natural gas generator.
The only trouble is that gives no indication when the power comes back on. So there you are, generator blasting away, while power is restored. Leave a couple circuits always connected to the line power, and hook those to a radio or a light so you know when the line is back up.
P.S. if you get a generator with an electric starter, odds are good the battery will be dead. The trick is to add a couple power posts to it, so you can jump start it with your car.
However, I think you can "panic buy" electricity. I live in a place with unreliable electricity. On hot days, I'm more inclined to cool my house with the AC earlier/colder than I would if I could absolutely count on the electricity being available. If the power goes out, at least my house is cool for a short while.
You have an incentive when the power to your residence or place of business goes out.
[0]https://www.publicpower.org/periodical/article/eia-forecasts...
"An abundance of hydro also means grid operators can be a bit less reliant on electricity from out-of-state sources. "[1]
[1]https://www.latimes.com/business/story/2023-01-18/california...
It doesn't matter how much generating capacity you have if you can't transmit all of it to where it's needed when all AC's are on full blast and everyone is charging their cars and everyone is cooking on electric stoves, or need to totally cut it off to large areas to prevent forest/wild fires during these extreme demand periods, which is when it's hottest. Blackouts/brownouts will still continue, and even be planned for, even with excess hydro. Infrastructure/delivery goes way beyond just raw generation.
It's a nice symptom of investments to the public infrastructure lagging.
https://www.utilitydive.com/news/grid-interconnection-queue-...
> The total capacity of energy projects in U.S. interconnection queues grew 40% year-over-year in 2022, with more than 1,350 GW of generation and 680 GW of storage waiting for approval to connect, according to a new report from the Lawrence Berkeley National Laboratory.
https://emp.lbl.gov/sites/default/files/queued_up_2022_04-06...
https://electrek.co/2023/04/19/tesla-reports-massive-increas...
The main problems are around interconnect and upgrading infrastructure. Lines and transformers are built to a certain capacity and connecting all these new projects could cause failures and blackouts. BEFORE you can even get approved, there has (historically) been a multi-year study required to validate everything. They are now doing them in groups of projects of 50 or more. However, then the estimates are for what would be needed for ALL 50 projects which is clearly overkill as they won't all pan out.
There is money in the Inflation Reduction Act to help upgrade the infrastructure and expedite the process but it is a trickle when we need more. The other approach is to just hook things up and wait until something breaks. Then the supplier would have to limit their capacity until they paid for increased carrying capacity. All said, this seems to indicate that infrastructure is the main bottleneck.
Once approved, the project still has to be built, correct? Is there a resource that lists plants which are actively expanding? That seems like a more useful short term metric to understand new capacity, because items in the queue may never be constructed.
Rather than rich people spending squillions on propane generators, how about spending less and fixing your damn grid?
https://www.construction-physics.com/p/the-birth-of-the-grid
Ah, if you click through to the actual stat you’ll see that without “Major Events” (whatever those are), the US goes down to 125 minutes per year.
Like, sure, if we wanted to we could massively build our electrical infrastructure to absolutely never go down. Hurricanes, tornadoes, massive hail, earthquakes, whatever. We can build so much redundancy and extreme engineering tolerances. It might cost us $1+/kWh though. Is it worth it? No? So then there's some dollar amount where we'll allow some downtime and failures for cost savings.
So what if the power in my house goes down a few minutes a year. I'd much rather pay a lot less for a few minutes of downtime than pay a lot more just so...the lights don't go out for a few minutes every now and then?
I’d also point out that Germany has its share of wild weather, including floods and storms. And yet they keep their grid up a lot more reliably than the US.
2 hours per year without power per year is probably fine. A year is a long time.
Like locked down OSes and hardware, locked down distributed energy resources will be the next place where you’ll lose your access to your devices due to corporate greed. The data and API access for DERs are like GOLD today. If you don’t control them, someone else will, and poorly. No company I’ve seen today is competent enough to scale to what’s going to be needed in the future. They’re all focused on cloud stuff, but at the scale energy works at and the compute necessary to efficiently use future energy systems, we’re going to need to switch to a distributed system on the edge, at the generation and load sites.
Edit: I’m in HN slow mode for some reason, likely that the fascists aren’t my fan today and have been flagging all my comments, so here’s my reply:
Sorry, no, but I mostly deal with commercial products. I know of the power wall only because my friend got them and they kinda suck. Tesla sometimes fucks up control, too, draining the battery for their own use to make money on their VPP. I suggest asking directly to the sales people if you will have full, free access to your telemetry in bulk to download and that you have API access to the whole system. Those are the two most important factors.
I'm using a Fronius Symo GEN24 in this way, I can access all features through the API, it can not suddenly update itself without my knowledge or consent. I do not have a battery attached yet since these are too expensive still and I can sell any excess power at market rates for the coming 5 years. After that time I expect battery prices to have gone down so I'll probably get a set of batteries which should enable us to be mostly energy independent from spring to autumn.
No third parties are involved in any way, no data is exchanged with "the cloud".
Edit: I'm also rate limited for some reason, a common occurrence [1]. No idea whether this is related to flagging, my UID being throttled by default or some other cause. It does not seem to be related to downvoted posts since I have been rate limited many times without any visible downvotes.
[1] documented in my profile at https://news.ycombinator.com/user?id=the_third_wave
Well, it wasn't a waste for the companies and countries who profited and their lobbyists.
In contrast, you can build a solar or wind plant in less than a year. And the profits for these end up in the local community where they stand instead of investment funds owning the nuclear plant operators.
https://www.scientificamerican.com/article/the-world-will-li...
But that would probably need some involvement from public sector and US public sector has been systematically dismantled since Reagan at least.
I am not saying it's not happening elsewhere, but I sure am glad that it's not going to be me and my family who's gonna eventually reclaim the public sector at the cost of watering the democracy tree.
Sorry for the irony. Have a nice day from EU.
Or does warming give us more cloudfree days?
> Many of our customers in Massachusetts want to know exactly how changes in heat can affect solar panel performance. Solar panels are generally tested at about 77°F and are rated to perform at peak efficiency between 59°F and 95°F. However, solar panels may get as hot as 149°F during the summer. When the surface temperature of your solar panels gets this high, solar panel efficiency can decline somewhat.
> ...
> For example, the temperature coefficient of LG NeON® 2 solar panels is -0.38% per one degree Celsius. This means that for every one degree Celsius above 25°C, the maximum efficiency of an LG NeON® 2 solar panel will decrease by 0.38%. Conversely, for every one degree Celsius below 25°C, the maximum efficiency of that solar panel will increase by 0.38%. (Yes — cooler, sunny weather is best for your solar panels and can help offset any decreased efficiency in the summer.)
---
https://greentumble.com/effect-of-temperature-on-solar-panel...
> According to the manufacture standards, 25 °C or 77 °F temperature indicates the peak of the optimum temperature range of photovoltaic solar panels. It is when solar photovoltaic cells are able to absorb sunlight with maximum efficiency and when we can expect them to perform the best.
> ...
> For example, if your solar panels have a coefficient of minus 0.4 percent, their output on hot days will drop nearly twice that much compared to the output of a panel with a coefficient of only minus 0.2 percent per one degree Celsius.
> White or light-colored roofing also helps to lower the temperature around your panels, since these colors reflect sunlight more and do not get heated up like dark roofing.
> While above mentioned points involve passive cooling methods, some people opt even for active cooling systems.
---
Extreme heat days, while they tend to be sunny often have poorer performance for solar while the demand for power (AC) goes up.
Just say we were wrong. “My bad”
We completely missed our 1.5 goal and the batteries are still coming.
It's not unreasonable to look to shifting to those technologies, but the course were on now of shutting down controllable power plants first is hard to characterize as anything but irresponsible.
There is a number to consider when doing this planning - it's called the capacity factor.
https://en.wikipedia.org/wiki/Capacity_factor
> The net capacity factor is the unitless ratio of actual electrical energy output over a given period of time to the theoretical maximum electrical energy output over that period.
In the US for 2018 data
Nuclear: 92.6%
Conv. Hydro: 42.8%
Wind: 37.4%
Solar PV: 26.1%
Solar CSP: 23.6%
Landfill Gas: 73.3%
Other biomass: 49.3%
Geothermal: 77.3%
Coal: 54.0%
Natural Gas CC: 57.6%
Natural Gas CT: 11.8%
Natural Gas ST: 13.7%
Oil ST: 13.9%
Oil CT: 2.5%
Hydro has a bit of variability that can get it better than nuclear if it has a retention dam rather than run of the river. Hydro may also be impacted by other regulations regarding excessive aeration of the water and fish spawning times (https://www.theatlantic.com/technology/archive/2011/06/massi... https://www.seattletimes.com/seattle-news/wind-power-and-wat... )This also depends on the month of the year (hydro provides more in the spring than in the fall, solar provides more in the summer than in the winter). The installed capacity of solar provides only a fraction of what it theoretically could in the winter when the days are shorter and the sun is lower in the sky.
Full off grid should probably not have to pay anything. But if something breaks you are on your own.
Why?
(Helps that it's well insulated and that hot water is central. hvac is not, but due to good insulation, hardly gets used except in summer)
It makes plenty of sense if you're operating on a small scale, on the order of tiny house territory.
This is obvious if you just imagine the extreme case; someone in a yurt on some land with just LED lights and laptop/phone/Starlink to power.
The cost of getting grid-tied alone would trivially blow out the cost of such a meager solar+battery+inverter setup. That's not even considering the recurring cost of power bills.
But I would agree it probably doesn't make financial sense to transition off-grid if you've already got the power poles and meter connected outside. Especially with a sizable inefficient American house...