by zerof1l · 3y ago · 0 comments
A little-known fact about these air quality sensors is that they don't actually measure three different particle sizes, they typically measure the smallest one and then return some statistically determined value for the larger ones.
[1] https://www.digikey.jp/htmldatasheets/production/2903006/0/0...
a) Data quality: You can detect if one sensor fails as the two readings will start to deviate and then replace the faulty one
b) Extend the life of the monitor: The PM sensors with the laser and optics have a limited life. By having two inside, you can alternate the measurement and put them in sleep mode inbetween. Thus extending the life of the monitor.
Instead of 50%/50% time split, can you do something like 40%/60%? This reduces the risk of both sensors failing at once because they have approximately the same duty time.
But how do you know which one is the faulty one?
In the theoretical limit of all mathematically possible failure modes and all possible environmental conditions, this would be impossible of course. But we live in a fairly predictable environment and the nature of the failures is not unlimited. As such, it is pragmatically pretty easy to see the difference.