53 points · by rntn · 2y ago · 124 comments
The solution isn’t more regulation or incentives, IMO. It’s to fix the utterly broken electricity market.
(This is a great example, BTW, of how public-private partnerships can be dramatically worse than full public control. Palo Alto, Santa Clara, and Los Angeles are doing quite a bit better.)
CA needs to get its incentives aligned to meet any of these goals. You want people to electrify? Just make it cheaper to run in the long term, and everybody will just do it by default.
https://calmatters.org/environment/2023/11/california-solar-...
They wanted the state to impose a tax on people using solar panels.
https://krcrtv.com/news/chico-residents-on-possible-solar-pa...
That's how you get exorbitant taxes on the alternatives
But we also need to stop waiting for intractable economic problems to be solved to address climate change. In the long run, the economic and human cost of not addressing this will far outstrip short-term costs.
So it doesn't really matter - it might if we build some nuclear or whatever, but right now, it doesn't.
Orthogonal, but I point this out all the time re: electric vehicles, when people claim "they are so cheap to operate!".
Do you really think that will continue to be the case when they are 10%, 25%, 50% of the market? The government will squeeze every dollar "saved" out of you. If you're lucky it will be equivalent to what you used to spend on gasoline.
Also, I can get ground source heat pumps installed including vertical wells for about 50k out of pocket, at current energy rates I'd recoup in about 12 years. Not sure where 50 years comes from, unless you are talking about geothermal and not ground source, in which case I have no insights in to as it's not a reasonable option around here.
Both in terms of cost and efficiency. You get all the advantage of heat pump, and the cheaper defrost cycle from gas furnace.
Consider how much of power generation wherever is gas.
If you can get residential power below 10c/kWh then HP always wins in cost, but most of the country has high electricity costs, low gas costs, and the ability to use gas when the grid is stressed.
You could go with a combo-boiler that does on-demand hot water and a single AUX zone rather than a 2-zone with a storage tank. However on-demand DHW doesn't do well with managing the temperature with pressure changes (someone flushes a toilet or puts the laundry on or both! and you'll get a few moments of either freezing or scalding water as it adjusts). I think it's better to have a superstor type DHW tank. They only lose about 1℉ per hour so with no DHW use, the boiler only needs to run about once a day for a few mins to keep it hot.
But in fairness, I live in DFW - I need air conditioning more than heat most of the time.
Of course this is all dependent on your home's specific heat loss calculation that's based on a ton of variables including location and construction methods, rooms above below, # of windows/doors etc. So in DFW, you won't need as much as in Concord NH. The (winter, 99%ile) ASHREA design temp for Concord NH is about 2F, but for DFW it's 27.5F, so the 10K BTUs for NH might only need to be 6K BTUs for DFW.
So a heat pump based forced hot water system might work well for you in DFW, but not me in NH because I don't have enough wall space for all of the baseboard needed at 120F -- I'd be better off with radiant heat with a heat pump because there you mix the hot water with the return to keep it (the water) no more than 100F or it'll either crack the concrete, or be uncomfortable to walk on. Also up here we typically have multi-story homes and also need basements because the frost line is 4-5' below grade, so radiant slabs are harder to build/install on a "joisted" floor than a slab-on-grade ranch home.
If I was building from scratch (in NH), it'd be a ground source heat pump with forced air system with radiant in the basement slab and a 2-zone high efficiency (propane/oil) boiler (unless Natural Gas, but that's rare in NH) with a super-stor type storage tank and hydronic loop off the boiler as AUX heat. There's a pretty good chance in NH you already have a suitable artesian well for the GSHP (just needs a variable speed pump).
The GSHP systems do have a "de-superheater" that can provide some hot water in the shoulder seasons so the boiler probably is only used in the winter (or if there's excessive DHW use).
Market adoption is already rising. Seems like a good way for the states to get good PR riding on the back of existing momentum.
Particularly in the North east you are going to find steam or forced hot water systems fired by gas or oil (most likely #2 heating oil or possibly kerosene).
In a new build yes. A forced air with (air or ground source) heap pump should be required (although it still doesn’t really solve the DHW issue).
Our house had an oil furnace, we added an air source heat pump. There are periods in the winter where the heat pump can't keep up, but in the months early and late winter it's all we need. The net result is that it has significantly reduced our oil consumption. Add to that fact it's an A/C unit in the summer, and it's wins all the way around.
The problem is most oil or gas fired heating systems are forced hot water (or steam) so a heat pump isn’t going to help you unless you want a mini-split in every room.
Even if you have ducting for cooling with AC it likely won’t have enough CFMs for heat in the winter unless it was specifically sized that way (but you likely wouldn’t be still using forced hot water or steam in that case).
At 30f - until you exceed 15-15.5 cents per kWh, heat pump is cheaper to run than median oil price.
The cheapest rate is 38c/kWh, the most expensive is 62c/kWh..
It’s not that a heat pump isn’t more efficient it’s that if you have forced hot water or steam radiators you are looking at an additional $40K to retrofit forced air ducting to your house. Oh and you still need a solution for domestic hot water, probably you’ll just end up with a resistive heater (or a hybrid/heat pump unit like the Aerotherm but the heat has to come from the room).
I have an electric water heater. It’s hybrid, so I run the heat pump mode in warm/humid weather and regular electric mode the rest if the year.
Mini-splits are not uncommon for cooling in the summer, but then again you only need them in the main living areas and bedrooms.
You don’t actually need it in every single room. A lot of rooms, you can get away with like radiant floor heating or electric baseboards.
Literally nothing about "pump" implies it generates heat. That being said...
> In colder climates, an electric heat strip can be added to the indoor fan coil for additional capabilities.
That would just be... electric heating, but with more steps? I mean, at that point you just have a heat pump _and_ electric heating; a hybrid system. It's better, sure, but it's not really just a heat pump anymore.
Thanks to improving refrigerant technologies, the “extremely cold” threshold is getting lower and lower over time.
I have a geothermal system (a ground-sourced heat pump) that also has electric resistive heating as a backup. I I've had to use it twice in the ~5 years I've lived in this house. The first time it was something like -15°f outside, so we just figured that was beyond what the system could handle. The second time, a year later, it wasn't quite as cold out and we had someone come look at it who found that it was low on refrigerant. (I've only been here 5 years, but the system was at least 15 years old.)
So, I've been happy it to have it there as a backup. From what I understand, it's also fairly straightforward and inexpensive to add to the system.
Expensive but falling as scale increases and government subsidies help drive scale.
Reliant on the grid - natural gas relies on the grid to move the air too. Not sure if this is the case all the time but mine won’t run at all without power, so unless you are referring to wood fired stove, natural gas furnaces are also reliant on the grid from what I can tell.
Gas/oil furnace can be powered by a small generator, solar panels or even a backup battery system, which is not the case for a heat pump. Oil / propane with local power generation can be fully off the grid.
Edit: the lower capital cost means you can also _afford_ a backup power supply.
Also, the largest heat pump in my house (I have a 6 kW and a 3 kW split system and a 5 kW air to water) also only uses about as much power as an electric kettle (~2 kW) most of the time here, I’m sure that could be powered off a small generator…
Natural gas heating relies on nothing more than convection to move hot water or (in older setups) steam from the boiler to the radiators. The only part of the setup where electricity is required is for electronic thermostats, and those can have a battery backup.
I was worried the bedrooms would get too cold when the doors were closed but it turned out not to be an issue. The bedrooms do get colder but this actually is better for sleeping.
We still have the forced air system as a backup.
I wish residential-sized gas-fired cogeneration systems were a thing.
A heat pump is basically just an air conditioner with a handful of extra parts to allow it to work in reverse. In the US they currently are significantly more expensive to install than AC, but I don't think it will stay that way for ever.
I think part of cost issue is that heat pumps tend to put an extreme focus on energy efficiency, leading to higher up-front costs, whereas AC units tend to balance a little more towards lower initial costs.
Any home that has both gas heating and air conditioning could replace the AC with a heat pump and get more efficient heating for most of the time, while still keeping their existing heating for situations that call for it.
I'm hopeful that AC manufacturers start shifting towards bi-directional units for their lower-cost "regular" segments instead of reserving that for only the fancy super-high-efficiency (expensive) units.
Another way to say this is "the consumer does not matter at this point" .. meaning that the game plan and expansion of the central corporate (or govt) operation is "more important" than the consumer benefit or choice.
Sadly, more than one thing can be true at once. If dramatic energy savings are "required" due to real structural problems, and also the well-capitalized and aggressive central entity can negotiate and implement the changes.. then it is a collective social situation.. End result - many advantages that small home owners have enjoyed in the USA for so long, are going away in real time right now, on a large scale.
Mini splits for primary heat.
Steam radiators with oil furnace as backup.
A ton of space heaters for backup backup.
Oh, and a wood burning stove in the living room for backup backup backup. If shit really hits the fan, I can crank the wood stove and surviving.