191 points · by trelane · 2y ago · 249 comments
> However, in December 2023 a fault with our electric oven popped the breaker for the sockets causing everything to be harshly powered off. My fileserver took it badly and one drive died. That wasn’t a huge issue as it has a redundant filesystem, but I didn’t like it.
> I decided I could afford to treat myself to a relatively cheap UPS.
Just from that, I'd say he for-sure should have avoided UPS's, and gotten a "real" surge protector. The "shockwave" from that high-amperage short is far more likely to have done the damage than the mere loss of power. And the output of cheap UPS's is often far worse than the input.
[Edit: And good surge protection is never a feature of cheap UPS's.]
If you have incredibly power-sensitive $100k equipment that needs protecting, maybe. But not for normal consumer electronics. None of them are that picky about the power.
I did find this older thread[1], but the answer is more of a "maybe if your PC or server is using an active PFC PSU." However, this is out of date (2015), and may no longer be correct.
Cyberpower's website says PSU with active PFC require pure sine wave.[2] But that might be marketing. IDK, seems like it something that may need to be tested to be sure.
[1] https://superuser.com/questions/912679/when-do-i-need-a-pure... [2] https://www.cyberpower.com/global/en/product/series/pfc_sine...
the cheapest APC models are notorious for this.
My own experience with UPSes didn't involve smoke or fires, but it did involve remote equipment going offline for months until I had time to make a trip out to replace the UPS with a surge protector.
Especially if it was 14 years old.
I'm not an electrician by any means so take everything I saw with a grain of salt, but: in general, electricity flowing through a system has some amount of "inertia" (the technical term for this is inductance), and shutting off a circuit breaker will cause a brief voltage spike upstream of the breaker due to the flow of electrical current suddenly being forced to stop.
Have you ever unplugged a running appliance from the wall and noticed a brief spark at the plug? That's the same effect: motors in general have high inductance and try quite hard to fight changes in current.
It's bad enough that when designing circuits that switch power to inductive loads like motors, you have to include a flyback diode (read: one way valve) to allow a path for electricity to continue to flow internal to the load when the power is switched off, otherwise it will generate a voltage spike high enough to damage the switching circuit.
Put another way: it's not the "high amperage short circuit" that causes the voltage spike; it's the rapid stop to said high current that happens when the circuit breaker realizes what's going on and trips.
Apologies - I know enough to do long-winded hand-waving on the subject...but if you want precise and concise (and really accurate), you'll need to ask a real electrical engineer.
I'm not sure if there's a decent UPS brand any more. I get the impression APC has been going downhill since the acquisition.
I’ve noticed a similar thing.
I had a 2005 Smart-UPS tower that never failed, but developed some transformer buzz that was annoying in an office environment—and hey, improved standby efficiency and an LCD panel would be nice—so I replaced it in 2013 with its latest equivalent. This one ran for about nine years and then started rebooting itself randomly, dropping the load each time. (It had no issues transferring and holding a load on battery, and self-test passed.) Its 2022 replacement now uses a non-standard USB-A male-to-male cable, is missing information that used to exist in the LCD menu, seems to have a problem charging from 98% to 100%, and has a broken event log (event 1 is always “Site wiring” and every other event is always “None”, even though there have been multiple power events, and there is no site wiring issue). It works, but QA issues are evident.
I’d previously tried a prosumer-grade CyberPower UPS (CP1500PFCLCD) on some other less critical equipment. When its battery failed after two years, it cut power to the load. When the charger failed a few years later, it cut power to the load. It died completely in about six years.
Tripp-Lite’s consumer grade stuff seems to work well enough for what it is, but their higher-end equipment seemed to all be designed for environments where noise doesn’t matter, which makes it a non-starter for an office. Eaton (their parent) seems the same.
So it would be great to know what is an actually good choice these days. At the moment I’m not in the market for anything and hopefully what I’ve got will run for another decade, but if it doesn’t, I have no good idea about what else to buy today.
Some UPS:es are adamant about wanting live and neutral on specific pins on the power plug and will throw that error message if they're swapped.
If it's a reversible power plug, flip it around. If the power plug can only be connected in one orientation the outlet is likely incorrectly installed (which is not all that uncommon, as 99.99% of stuff will work perfectly fine with live and neutral swapped).
I've never (n=4) had a stock CyberPower UPS battery last me 2 years. 3rd party replacement batteries have all lasted significantly longer than what shipped in the box.
In my home right now, I have an APC (Schneider) Back-UPS Pro 1000, Tripp Lite (Eaton) AVR550U, and CyberPower CP1500PFCLCDa.
I purchased the APC in April 2017, the CyberPower in Nov 2020, and the Tripp Lite in Sep 2021.
The APC was originally for all my IT gear but for some reason that load caused it to cycle to battery at random times. I replaced it with the CyberPower which works fine with my IT gear. Meanwhile the APC works fine with my AV gear where I re-purposed it.
Both of those are still on their original batteries which I test every 6 months.
The Tripp Lite I use at my desk and I also test it every 6 months, but last month the power went out and the Tripp Lite immediately shut down. The battery had failed w/o warning and the Tripp Lite battery-monitoring is apparently useless since it still thought the battery was good when power was restored, but an actual load test proved otherwise.
When I replaced the battery, the Tripp Lite had a cheap Chinese battery in it. I replaced it with a Duracell (manufactured in Vietnam). I've had less trouble with non-Chinese UPS batteries.
Another fun thing: Tripp Lite has reused the model "AVR550U" for three different UPSes all which use a different battery. Turns out my version uses the quite common APC RBC2 sized 7Ah battery.
Which is all to say: I've had a lot of UPSes over the years and you can't make any claims about any single manufacturer. They all manufacture a range of models and none of us have any actual data about failure rates. The best you can do if you have the expertise is to take one apart and evaluate its design and manufacturing quality.
Such UPSs are available in small rackmount units.[1] The usual serious players, such as Tripp-Lite, have LiFeP04 battery powered units. Searching for consumer-grade LiFePo4 UPSs turns up many articles on how to replace crappy batteries in UPS units with newer battery technology. The batteries themselves are cheap now. APC doesn't seem to have caught up yet.
This looks like an APC corporate problem.
no, and afaik it's a cost thing. the unit you link is "request for quote" and being a rackmount unit it's probably not what consumers would think of as inexpensive.
I have three of the classic fire-hazard cyberpower 1500PFCLCD and each of them has a pair of small sealed lead-acid (SLA) batteries that cost maybe $30-40 each to replace. If you assume that the OEM gets them for $20 apiece, how much LiFePO4 battery does that buy? I know the big industrial cells are cheaper than what you can get as small individual cells, but I'm positive it's still going to be 4-10x more expensive.
now remember that's a unit that retails for $135-150, and there are like 3-4 tiers of units below that... how much LiFePO4 can you buy for $10 to put into that $50 UPS?
(fake edit I looked one of them up from the datasheet and it's $700 for the lowest-tier 1000VA unit lol)
That's the bigger issue, that there's nothing medium price.
I can get a LiFePo4 battery that can do well over a kilowatt for an hour for <$150 with free shipping, and I can get an entire UPS for <$100, but the combination costs so much more.
If someone knows different, I'm all ears.
EcoFlow Delta Pro - RTFM Dummy! EEVblog2 https://www.youtube.com/watch?v=5JT8M8v_zNg
Bluetti dos much better:
Bluetti AC500 / B300S Power Bank - Review & Teardown mikeselectricstuff https://www.youtube.com/watch?v=RuEO17uvI8M
> about the same energy density per cubic meter
Energy density isn't the issue. Need to either buy the best cells or oversize the pack to meet normal loads. Both options cost additional money.
Go look at the spec sheets on the cheap ones, they aren't power dense enough to make a small (1000-1500VA) UPS with comparable or even double runtime of the lead acid.
(Generally, such a protocol is a better option from a compatibility point of view: it's usually fairly easy to reverse engineer. It would be interesting to sniff what the windows software is doing to work out what protocol or behaviour difference is responsible)
This isn't to say it's good, just that it's not new.
The serial port serves dual-purpose. Along-side the obvious serial, you can also provide some inputs by grounding certain pins, and some outputs by sinking current from others. This has got me through some unorthodox integrations by having the UPS signal that it's on battery by having these "simple signals" close a contact/relay on the load. It's not quite a full suite of dry contacts, but it's pretty serviceable.
The problem is that 9 pins doesn't leave many spare, so to achieve this they've repurposed some. I really wish they'd implemented this as an alternate mode so you'd, for example short tx to rx to change the behaviour - instead of having the 'alternate behaviour' sitting on standard DTR/RTS pins.
Getting industrial interfaces at SOHO prices was awesome. The unintended consequences .. less so.
It works perfectly with apcupsd though, even showing up in my desktop power settings as a UPS.
OTOH, the older UPS behaves much better with apcupsd, going so far as giving me the firmware versions, battery replacement times, better power monitoring/etc. While the new one works its missing most of what the older UPS could do (although its not a APC).
So, i'm sorta on the fence about just using "backup generators" from Amazon/etc because one of the ones I have has about 5x the capacity of the new UPS and seems to be able to switch without the computer plugging into it having an issue. Plus, its power waste is less than 1%.
The batteries are definitely worth more than the unit is at this point.
A backup generator for me is not an option but this is mostly just to keep internet and a couple machines going in the event of a power failure. One day maybe the used lithium ion one will pop up and I will swap it out.
At least here in Australia, replacement batteries for some of the common UPS's (for desktop usage) cost nearly as much as the UPS itself.
* I didn't need more capacity (the one I bought will power the server it serves for an hour, far more time than I need or want) and, more to the point,
* The larger-size model has two batteries to replace, significantly increasing the cost.
[1] One such example, replacing with a generic kind: https://www.youtube.com/watch?v=R6qcon76i4s
Com port is a standard USB-B port and is compatible with but
https://www.telephonewreckers.com.au/power-shield-safeguard-...
My only complaint is the formfactor is about weird.
Second, for people who can't necessarily afford either new UPSes or something other than "consumer grade", a good option is to find local sellers, perhaps on Craigslist or Facebook Marketplace, who are selling or giving away old UPSes. Many people and businesses don't bother replacing batteries, so they just buy new devices when the batteries near or reach end of life, and since they're heavy, they often just want to give the hardware away.
New batteries are not expensive. A common 9AH battery for many / most common smaller UPSes costs around $25 USD from Amazon sellers that have 4.5 or more stars.
I've personally never bought a new UPS for myself, yet all of my equipment and everywhere I've set up home Internet equipment for others has UPSes. I've only ever bought batteries. Just a thought.
2024-01-30 08:15:13 -0800 Power failure.
2024-01-30 08:15:19 -0800 Running on UPS batteries.
2024-01-30 08:20:06 -0800 Mains returned. No longer on UPS batteries.
2024-01-30 08:20:06 -0800 Power is back. UPS running on mains.
2024-02-04 12:52:58 -0800 Power failure.
2024-02-04 12:53:04 -0800 Running on UPS batteries.
2024-02-04 12:54:04 -0800 Mains returned. No longer on UPS batteries.
2024-02-04 12:54:04 -0800 Power is back. UPS running on mains.
2024-02-18 12:10:13 -0800 UPS Self Test switch to battery.
2024-02-18 12:10:21 -0800 UPS Self Test completed: Battery OKWait, what?
Does it also heat your room? How can it be so power-hungry?
55.2 watts
The "xFi Advanced Gateway (XB7)" router is definitely warm to somewhat hot on the outside. The AC here varies from 118vac to as high as 126vac (maximum rating.) Right now it's at 122vac. I think my 185 watt number might have been 123.3vac x 1.5a, or maybe it was the previous "xFi Advanced Gateway (XB6)" which was also a chimney.I am not an ISP. We work remotely — there is no fiber here yet.
https://www.juniper.net/us/en/products/routers/mx-series/mx3...
Random example from a search. According to a calculator I plugged a few values in, it's 2880 watts, but not sure I computed it correctly.
My own router's PSU is rated at 36 W, for comparison.
The model he is referring to is the last UPS I owned and had some very serious QA issues;
https://www.eevblog.com/forum/dodgy-technology/apc-ups-now-w...
We had a bunch of Cyberpowers and they were absolutely crap. The failed at a high rate and had terrible software.
https://www.apc.com/us/en/product-range/61877-liner/?parent-...
It can be removed[5], with some effort, though. Given its use in various electronics it wouldn't surprise me if some other UPSes use it, though have only seen discussions about Cyberpower.
[1] https://sound-au.com/articles/yellow-glue.htm
[2] This thread had various videos from users showing the arcing on Cyberpower units: https://web.archive.org/web/20220715134034/https://old.reddi...
[3] https://www.youtube.com/watch?v=9gqBzLNMFe4
[4] https://news.ycombinator.com/item?id=31954938
[5] https://www.eevblog.com/forum/beginners/how-to-remove-the-dr...
But manufacturers don't use it. Maybe they haven't redesigned after the price dropped. Or maybe cause prices is still too high. I think LiFePO4 would be most useful for rack mounts, or small UPSes that aren't possible with lead acid.
Generally lithium UPS win in a 10-year TCO, but SLA wins in up-front costing. Which leaves us with two issues - most consumers look at the sticker price not the TCO, and no-one wants to market their products as "Our lead acid offer only /looks/ cheap, until you see what we charge you for consumables!"
It seems like a fairly recent shift -- heck, the whole solar generator concept is a fairly recent shift -- but maybe it's an indication that LiFePO4 devices are becoming more common in the consumer space.
Things may have changed, the APC UPS systems I've used required you to power off to replace the batteries. the CyberPower units I've used allow for replacing the batteries hot.
I've had terrible results with Tripp Lite UPS systems - where they fail for no reason at all, and will not auto power up after a power failure.
At a very large size of 30KVA, I've used Eaton UPS systems and they have been rock solid.
In the winter months (when we have most of our power outages), I pay for a pre-paid cellular SIM for backup. The cell tower(s) that serves my area must be on generator, it doesn't seem to go down even in long power outages.
I guess you could have a bad cable where the CC wire has broken and can't do USB-PD.
Their customer service is supposed to be legendary. If you drop them a (polite) descriptive note, signed with your name and address, I'll bet you a beer that you'll have a new cable in your hands by the middle of next week.
The only advantage to buying new is weight. Newer UPSes tend to be a lot lighter, but that's often because they cut corners on the magnetics and/or use expensive, hard-to-replace lithium batteries. Weight is a high priority for the manufacturer to optimize, but not for the consumer. When it comes to UPSes, old school big-iron transformers and heavy-metal batteries are the way to go IMO.
Also like everyone say... remember to look for pure sine wave output if you are going to "protect" servers, for network equipment you could use the pwm based ones.
At home, I have had a single rack w/ network and server gear for more than a decade and I always run two good quality UPS, that I run a test on annually, tied to two different circuits. My setup now is a bit annoying because I'm renting currently, but when I owned a home prior to my recent move I had an electrician run two 20A Dual Function (AFCI+GFCI) circuits with hospital grade outlets to power the two UPSes in the same room but on separate circuits and breakers at the panel. I don't think that's overkill, but I think anything more would be overkill at home. When I buy a house again, I intend to do the same.
Since buying better quality UPS and testing them regularly so I can replace batteries when needed I haven't had any fires, but using batteries past their useful lifespan can greatly increase risk of fire. Expect that you should replace the batteries every 3-5 years, and that they will cost nearly as much as the UPS itself. If you're not comfortable with that, invest in a quality surge protector instead and figure out how to deal with failures. UPS batteries are a big fire risk, so you need to understand it and work to contain it. Also, keep a good dry fire extinguisher near your rackmount equipment and get it tested annually.
For home use I bought a lead acid UPS specifically to avoid a fire. For a 5 hour power outage it makes no difference to me if the UPS powers my machine for 5 minutes or 20 minutes; as long as I can save my stuff and shut down it works for me.
Don't do this. This is a terrible idea if you intend to run a UPS.
> with hospital grade outlets
Complete overkill and waste of money
> UPS batteries are a big fire risk
No they aren't.
Judging by all these incorrect assumptions about electrical, I'd suggest stopping while you're ahead before you burn your own house down.
For anyone reading this, this person has no idea what they're talking about. Besides the fact that I once considered becoming an electrician and completed my apprenticeship prior to entering the tech industry, it is a published standard how things should be installed in residential properties in the US, called the National Electric Code or NEC.
The NEC 2020 states that GFCI is required (in additional to a general AFCI requirement) for any 125V or 250V receptacles in kitchens, bathrooms, laundry areas, finished or unfinished basements, garages and anywhere within six feet of a sink. Since my server rack was in a closet in a finished basement, it is /REQUIRED/ by code to have a dual-function breaker.
Also, I once again refer you regarding fire risk to simply search "UPS fire datacenter". UPS fires are the primary cause of datacenter fires. But sure, I don't know what I'm talking about, I've only been responsible for multiple datacenters spanning the globe for one of the world's largest hosting providers as part of my career after giving being an electrician a go and deciding against it as a career in my youth.
If anyone is ever in doubt about how to install something that's electrical: 1. Hire a certified electrician and 2. Read the applicable standard, which is the most recent published version of the NEC. Don't listen to people who make rude smart-ass comments on the Internet.
Do you have a source for this claim? I can find no documented evidence of it being true.
The Uptime Institute found[0] data center fires of any cause to be exceedingly rare. Data Center Incident Reporting network reached similar findings[1].
The only example I could find of anyone claiming data center fires have a principal cause is this article[2], and while I'm not saying it's wrong, I've never heard of these folks before and have no idea how credible they are:
"Electrical failures are the most common cause of data center fires. These failures can stem from overloaded circuits, malfunctioning equipment, or defective wiring, each capable of generating sufficient heat to ignite a fire when in proximity to combustible materials."
(Note: they break out battery fires separately, so they are not supporting your claim that batteries are the most common cause of data center fires.)
But, in any case, with details about data center fires being so rare, either because they are rare or because people don't want to talk about it, stating a primary cause accurately seems to me to be very difficult.
Lastly, since you've run multiple data centers, surely you understand the scale of the battery strings involved. Total energy storage is way higher, ampacity is higher, and to the extent lead acid batteries are involved, much, much, more hydrogen off gassing is possible. I just don't see how you can extrapolate that down to fire risk for a 12V, 12AH battery found in a typical home UPS.
0 - https://journal.uptimeinstitute.com/datacenter-fire-frequenc...
1 - https://www.datacenterdynamics.com/en/opinions/how-frequent-...
2 - https://dgtlinfra.com/data-center-fires/#:~:text=Electrical%....
Also the NEC has gotten ever more outlandish with those requirements. Like last time I looked there was no exception for sump pumps, yet you'd be foolish to actually use a GFCI there. Actually a quick search says it's now even explicitly required. rolls eyes. I mean sorry, I'd love to but I'm just too busy restraightening all the prongs on my plugs due to these wonderful "tamper resistant" receptacles.
> Don't do this. This is a terrible idea if you intend to run a UPS.
Can you please elaborate why someone shouldn't do that? (not who you responded to, I'm just curious about the reasoning behind that statement)
This advice is specific to the US & Canada where GFCI's are calibrated to trip at 5 mA. In the UK, their RCD's trip at 30 mA so it's less likely.
If you read the fine print for your UPS and/or GFCI they will say not to use them together.
What about AFCI's? Well they are basically nuisance devices by design and most electricians hate them. Do not use unless absolutely necessary by code.
The difficulty comes into play because UPS's, servers, etc are essentially industrial equipment while the code is written for such common residential usages as plugging in a lamp (where a dog will chew on the cord, a good way to start a fire hence a perceived need for AFCI protection.)
What if you're stuck because you want to locate your UPS and equipment in an area where GFCI's are required (like a residential basement)? Well I won't tell you what to do in your own home but I'm sure you can devise a creative solution. :)
FWIW, running my server and network equipment never caused the breaker to trip erroneously while I was still living there. I sold the house when I moved cross-country for unrelated reasons so I can't say what happened afterwards, but my setup was installed according to code and functioned perfectly fine. I used quality UPS and decent quality network and server equipment. Cheap stuff may be farther out of spec and have more issues with leakage current.
However...I discovered why some APC UPSes are sealed and the battery cannot be accessed. I was converting one such UPS which had no monitor interface. Having already opened it up to splice in an external battery, I noticed an empty header for a serial port. Cool. Plugged that into my PC and flash/bang/smoke. Fortunately my PC had a good path to ground and was not damaged. But the UPS had some pretty large burn marks at various points in the PCB and was certainly dead.
It took me a bit to figure out what I did wrong. The reason it went bang is directly related to why there's no user access to the battery, and why there's no external monitoring port. They went cheap on the electronics and did not include an isolation transformer. Any points within the UPS which are "ground", including the battery negative terminal, are actually referenced to the full bridge rectifier, which provides a direct path to live. Ahh...I'm just very glad I didn't touch any of the battery terminals while I had the thing plugged in.
Is the idea to protect against a breaker failing, a wiring issue, or something similar?
“Something’s wrong with your..."
"Returning to my thread on the apcupsd mailing list, I asked again if there was actually anyone out there who had one of these working with non-Windows."
Linux's reputation in a nutshell. It just works after you spend days checking if you have a bad device and another on the mailing list. And then you are forced to find a working alternative.
"Linux Compatibility" often means "someone got it working once 6 years ago, on an extremely out of date version of the OS, but its probably still fine".
As a counterpoint to your experience, I've had great luck buying laptops off of Canonical's approved hardware list.
As a corollary, I've had worse luck buying computers that come with Linux pre-installed, only to discover that the pre-installed distribution is very specifically and carefully configured and includes proprietary bits and it's impossible to install any other Linux on the device or upgrade it.
Intel/AMD: probably fine. Realtek: works, one driver codebase for everything means weirdness is likely. Broadcom: don't even bother. Nvidia/mobile: what kernel/stack are you intending to use?
I haven't had to care about compatibility with desktop or server components in over a decade.
It's fingerprint readers and dual-GPU laptops that really bum a lot of people out.
And yes, I never check for Windows compatibility before buying the actual hardware/software. Not even /s.
The best Linux can do as an ecosystem is reverse-engineer some stuff, which may or may not work for all models for varying degrees of "work", and that's it. The people working on apcupsd probably don't even have access to this model, and they're probably also not keen to dish out several hundred Euro/Dollar/Pounds to purchase one at their own expense.
Often things are complex and multiple people are "at fault" for something going wrong. Sometimes it's very simple and it's just one party doing something wrong. This is one of those simple cases. Linux is very much not "the problem", crummy vendors with crummy undocumented protocols are "the problem".
I do not usually check for hardware compatibility with Linux either. The only things I have checked that I have bought in the last few years have been graphics cards and USB wifi, and the latter was just a matter of reading product descriptions.
A lot of software I use either does not run on Windows, or is harder to install or is less mature on Windows. Obviously lots of server side stuff, but even some desktop stuff I would be doubtful about because the bulk of users are on Linux.
Not surprising that given a mostly volunteer effort... it just doesn't happen. Or vendors self-certify their own gear.
https://learn.microsoft.com/en-us/windows-hardware/design/co...
Don't buy a consumer grade UPS if you want to monitor it properly.
Is there a power delivery equivalent of Ubiquti (I know we’ve discussed their shortcomings here) that offer better than consumer grade for less than enterprise prices?
Of course there is no native signaling on grid loss, but in practice that's not an issue; for planned maintenance I can force charge the battery and keep the servers running for a day or more, and actual power loss incidents are very brief in my corner of the woods.
So yes, Linux is still not on par with Windows in many ways, but boy oh boy was it weirder than it should have been to format a USB drive to install windows.
I lost a solid 6 hours to that try, yay it work, wait I'm getting a nonsensical error at a strange screen. Retry with different flags, with different hardware, etc etc etc.
Afraid your ups will hack you?
Yes, I am afraid my UPS will hack me. More specifically I'm afraid this badly written closed source software will have some security hole that can be used to escalate to root.
We are talking about apcupsd right?
Were you under the impression it's official software done by APC?
If you're home when it switches to battery power, the equipment will probably have been protected from any surge, and you'll hear the beeps from the UPS, and can manually shut down equipment.
If you're not home, and the power doesn't come on soon enough, power will be cut to protected equipment, without a surge, and at most the equipment probably only needs the auto-`fsck`.
And because no monitor means that you can have the UPS airgapped for data, there's less theoretical risk of a remote firmware hack causing a fire/explosion or toxic leak.
I have a homelab of a few servers, with a nice rackmount UPS, and I decided data connection to the UPS is more risk than good, in my case.
Environmental monitoring doesn't have to be part of the UPS. And APC has long made separate devices for that, for data centers/racks. In addition to the modern IoT home devices.
It sounds like the Windows software probably debounces the incoming events, only bubbling up those that are sufficiently time-stable, to account for bargain sensor false positives?
Edit: Looks like the apcupsd collection also has some EEPROM programming utilities... (for supported devices) http://www.apcupsd.org/manual/#configuration-directives-used...
> popped the breaker for the sockets causing everything to be harshly powered off. My fileserver took it badly and one drive died.
Maybe someone with more hardware knowledge could chime in, but my default assumption would be that the hard drive died either because it couldn't take another power-off/on cycle, or because the event that caused the circuit breaker to pop was harsh enough to damage it (not sure how much the computer's power supply insulates components from things like that, but intuitively, there are much more voltage-sensitive components in PCs than hard drives). While a UPS might have been effective against a surge, it would not have saved the drive from dying by power cycling.
My hypothesis is that most equipment doesn't need to be notified when on UPS, it could in fact be harmful when it causes a power cycle that turns out to be unnecessary. An orderly shutdown doesn't matter that much unless you're dealing with an app that can become internally inconsistent, such as a database. In all other scenarios, the journaling FS takes care of data integrity.
So, especially for home use, why not just let the UPS run until it's out?
> Even worse, two of the fifteen devices became massively corrupted, with one no longer registering on the SAS bus at all after 136 fault cycles, and another suffering one third of its blocks becoming inaccessible after merely 8 fault cycles
There were only a few times (maybe 2 or 3 in all that time) when I saw some messages indicating that something was wrong with the battery (though they never were as frequent as in the author's case). In each of those cases, the messages went away after replacing the battery.
* Back-UPS: stand-by, Stepped approximation to a sinewave
* Back-UPS Pro: line interactive, Stepped approximation to a sinewave
* Smart-UPS: line interactive, Sine wave
* Smart-UPS Online: double-conversion online, Sine wave
My local electric is pretty stable, I no longer run servers at home that need to be up 24/7, most of my work at home is on a laptop with integrated battery backup, I can use my phone WiFI AP mode for backup Internet, UPSes are a pain to move between apartments, and UPSes have a small risk of dangerous battery leakage.
Are the lithium-based batteries more durable (probably more dangerous)? Anyone have experience with these? https://www.amazon.com/Xtreme-Power-Conversion-J60-600-Lithi...
I had to configure an udev rule though for it to set up a static USB device name since that wasn't happening out of the box, but other than that - no problems.
So, yeah, it's understandable why people might not be buying Eaton.
What makes Eaton products better? Sincerely want to know anything you can tell me.
We have an Eaton and several APCs, all fairly cheap/lowend. One recent power outage, the APCs flipped on but the Eaton just turned off...
SUBSYSTEM=="usb", ATTR{idVendor}=="0764", ATTR{idProduct}=="0501", GROUP="nut", ATTR{power/autosuspend}="-1"
I purchased a UPS that supports a network management card, basically an overpriced SNMP daemon with an Ethernet interface, and have been happy ever since, since every system can query the status of the UPS.
If you live in EU go with 110-220v charger so your setup can outlive a brownout.
PicoPSU is the way I solve this.
NMC2 and NMC3 can't even install proper SSL certs without some shitty Windows-only tool.
I'm not seeing much of a point powering a small server from battery with AC if it all gets converted to DC anyway. Laptops got it right.
I doubt this one in any of the patent pools (OIN) but maybe they wouldn't sue anyhow?
Doesn’t help anyone running Linux though. :/