by neilv · 2y ago · 0 comments
I like the idea of solar, and of backups, and of figuring out how to live comfortably in rentals, and of being mobile, but...
I'm pretty sure that my own real-life landlord would flip out, if he came to the door, and saw that charger box bolted to the wall, and the bare terminals of an Alibaba special "SCREMOWER" large lithium battery pack.
Before he even saw that cabling. Which I think (with those lengths, and tacked up like that) would be an electrical code violation here.
Would insurance even cover a fire?
Also, if there's later an expensive roof leak, there'd be questions about whether it had been caused by installation of the panels (even though no holes were drilled). And is there a liability risk if the panel gets blown off.
And would insurance cover any of that?
Were I in landlord's position myself, I'd have much of the same concerns.
Safety hazards I see include: Solar panels on the roof that aren’t bolted dow; I don’t care what wind speed they’re rated for. Wires running from them to the inside of the house not in conduit and not secured. A high energy battery pack not NRTL listed. Extension cords draped through the house permanently installed (within the expansive definition of permanently installed used by the NEC)
In addition running the wires in through a cracked window creates an unacceptable risk of water damage.
That said, it’s a cool project. Just do this in a barn you own not a house I own.
Even once solar makes sense for the house I live in, its a tougher sell in a rental: If I were to do install solar on a rental, there's the added complexity of "how do I charge the tenant for electricity?". I could not charge them, but have higher rent. But it takes a pretty sophisticated tenant to properly account for the value there, so that would make the units appear less price competitive than they actually are. I could install a meter and charge them the same way as a power company does. But does that make me a power company? Are there a bunch of new rules I would have to follow? What do I do if someone doesn't pay the bill? I'm sure I could figure it all out, but it makes the investment less attractive, which means the price of solar relative to buying from the grid has to be even better before I would go down that route.
(edited for typos)
Just buy another electricity meter and install it after the inverter.
It seems like there are two justifications for solar if you’re on the grid. Either you want to do right by the environment (totally good, though very pricey, reason to do it!) or your electricity costs are very high. If there are others I’d love to understand them. Maybe if you’re a prepper (not making fun) then that’s another reason.
How does one stop tenants using "dodgy" chargers to charge their electric bike or whatever, and the battery bank causes a fire.?
Does your insurance cover these situations???
That said, I drive by all my properties periodically, and my property manager does annual walk through; large battery banks, excessive extension cords tacked to the walls, and solar panels sitting on the roof with wires run through a window would all get flagged in such a walkthrough, any my rental agreements allow me to require the tenant to correct unsafe conditions, which all of those are.
And I do have good insurance. There's a pervasive believe on HN that you can't get insurance that covers variations of not-to-code, not-properly-permitted, and/or not-done-by-licensed-electrician electrical installations. There very may well be insurance that excludes these things, but its easy to get insurance that covers those things, and mine does. If my tenants do dumb-ass stuff that burns the building down, I'm covered, even if that dumb-ass stuff involves electricity.
If you stop being a parasite perhaps one could afford a barn.
Someday we'll wonder why we thought it was a good idea to make the need for shelter into an investment vehicle. Until then, I hope people use your properties as they see fit.
I'm in a fortunate situation where my landlord is not a slumlord. When things need looking into, it gets taken care of in a timely manner. I do not have any issue with someone choosing to have this as a business.
It's likely the shelter will be on this earth longer than I will? We didn't make it that way, it is that way.
There's a set of circumstances that make it so. Low interest rates, being able to use leverage (borrow money, buy a house then rent it out), and higher-than-inflation price increase of houses.
Don't get me wrong, I like that dream too. I just have my thoughts about the current housing market, which to me has aspects of an investment market.
tldr: land value tax and less restrictive zoning yesterday
The manufacturers are well aware of risks, for liability reasons if nothing else, and have contained them in the uniform-electrical-code mandated manner. The system is no more risky than any other plugged-in appliance. We don't need to invent problems. Extension cords are just extension cords.
that this system won't exceed ratings is a fair point, but extension cords are not just extension cords.
All the appliances mentioned are rated to be used with appropriate extension cords, and cords are sold at retail for such use.
For any type of generator running exterior to interior would require rated extension cords to reduce fire risk.
The only outdoor wiring mentioned is 48V.
Ive taught a bunch of in person classes on DIY solar and I would never have published this, its asking people to get evicted or worse.
I should add, mine are all in the context of fringe living... vans, campers, boats, alleyways, etc.
Explaining that to the landlord may not be fruitful however.
That's actually one of my bigger concerns with these solar into battery stunts is where to place such a massive array of batteries such that if something caught fire it wouldn't take out my roof or other flamable stuff
Since I apparently couldn't buy one then it doesn't matter but I would need to further understand what happens <s>if</s>when those pumps fail
Thermal runaway is really bad. Typical lithium rechargeable batteries can't handle overheating without starting a chain reaction: an uncontrollable thermal runaway followed by a literally inextinguishable inferno.
If you short circuit the LiFePo battery it still is going to turn into a welder. It can still start a fire. If you don't short circuit it, under normal conditions it shouldn't spontaneously combust.
1. Note: Confusingly LiFePo4 (Lithium Iron Phosphate) looks a lot like LiPo (Lithium Polymer), however, LiPo batteries are some of the most prone to fire while LiFe batteries are the least prone to fire.
> Rule 64-918 (1) further prohibits ESSs with storage capacity greater than 1 kWh or utilizing lithium-ion batteries from being installed in dwelling units.
The reasoning for that rule is "fire hazard". There is zero exceptions.
The 2024 edition has 2x 20kWh allowance in a 1h fire proof room spaced 1m apart. And you need a series of fire prevention tools like an extinguisher and such. But that is not yet implemented.
Most landlords here are pretty low maintenance (both ways) as long as you pay on time and willing to bend. Did not blink an eye when I asked to go roof WISP and drilled my own hole next to the cable line. No roof penetration so they didn’t care.
I’m thinking of asking about a weighted panel to cover the 4-9pm PG&E quadruple pricing via a LFP bank.
Yes. Insurance is a contract, and the standard insurance contracts used by nearly all insurers do not contain exclusions for permits, code violations, or things like this. They would absolutely not renew you after a loss caused by something like this, and would probably report the loss to the industry databases. Insurance companies will often try to impose liability on other parties when losses happen, but they don't sue their own customer, as the whole point of an insurance contract is that they are assuming liability for loss in exchange for your premium. (If you believe this to be otherwise, try to find a recorded instance of an insurer denying coverage for code violations or un-permitted work. I've never been able to do so, and would be very interested in reading the case study.)
If you want to be sure, just ask your insurer for a copy of your contact, and read it. They aren't that complex.
I wouldn’t condone this or any variation thereof that violates the NEC, a lot of liability is being assumed by doing this.
I realize not everyone can afford a new home but with the proper knowledge and tools you can make electrical changes to achieve your goals that can be reversed on move out.
I might have previously done things against my landlords wishes but it was done - and removed - professionally. The other option is to talk to your landlord and do it right, making it permanent upon your separation from the property.
Good point about the possibility of a roof leak and placing blame. I didn’t think of that.
Also more recently I learned that these things can vibrate. Which would not be good for a window.
You’d be better off passing a wire ribbon around the sash.
But still inspired me to perhaps to something like this that bypasses the meter and the city grid, but just a little more limited in scope than running duplicate wiring everywhere.