by javagram · 2y ago · 0 comments
Not sure if there is a significant climate difference in the UK that makes this construction more problematic, the article mentions moisture but the U.S. building scientists say 2 inches closed cell spray foam will block air and vapors from reaching the wood of the roof. Perhaps the issue is the open cell foam mentioned in the article - it seems that closed cell foam is the recommended type in the USA.
Implementation details matter. From the OP's article:
> At the root of the problem are cowboy traders who apply the foam without a full survey or appropriate expertise – but because of lenders’ caution, this is affecting other homeowners who had similar work.
One potential problem that could occur is ridge rot:
> Lots of attics insulated with open cell low density spray foam (Photograph 1, Photograph 2 and Photograph 3) are having problems – in hot humid climates, mixed humid climates, and cold climates. The problems are moisture related. The attics are “unvented” – open cell low density spray foam is installed directly on the underside of roof sheathing. The attics are humid. Very humid. Unacceptably humid. And the humidity collects at the upper portion of the attics.
* https://buildingscience.com/documents/building-science-insig...
> When you spray ocSPF into wall cavities from the interior the ocSPF can act as the air control layer and thermal control layer. It can’t act as the vapor control layer – it is too vapor open. This is a problem when you spray ocSPF on the underside of roof/attic assemblies you can end up with problems (“Ping Pong Water”).
* https://buildingscience.com/documents/building-science-insig...
The reason it's nonsense is that the side covered with foam (especially closed cell) is now protected by waterproof polyurethane. Water isn't getting to that side.
The other side is now insulated from the inside, so that isn't getting things like condensation because the temperature differences should be negligible. If people think about a cheap styrofoam cooler, it's cold on the inside and there isn't condensation on the outside on a humid summer day. The outside isn't cold, that's the point, so condensation doesn't happen there.
Then maybe someone would say if there was a roof leak the wood would get wet and rot, but that would happen anyway. That's a major disaster and foam won't cause any more problems than are already happening.
This is especially true for hack jobs on older buildings.
A lot of people spray foam in old attics as a set and forget insulation measure: https://www.stellrr.com/wp-content/uploads/2021/04/AAF45418-...
Why would water be able to get through your roof with spray foam making anything worse? Water damage means you have to replace things anyway.
Because your roof _will_ fail, they all do, once it does the water will collect between the roof and the foam, because while it's not air tight there will be nowhere near enough ventilation do get rid of it
> Water damage means you have to replace things anyway.
Yes, but if your entire wooden structure rots for 5 years because you didn't detected the leak since it's hidden behind 20cm of foam you are utterly fucked.
It's well documented, feel free to google it if you don't believe me.
https://sprayfoamreclaim.com/wp-content/uploads/2022/10/PHOT...
Why? It isn't like water will get through metal plates, at least not within many decades.
You'll always have a failing shingle/tile here and there, unless you plan on inspecting the whole structure under the foam every year you could very well miss it for many years.
A puddle in the attic or a wet rock/sheepwool panel will be much easier to discover/fix. A small leak under 20cm of sprayed foam will be a nightmare to locate
https://www.24-7pressrelease.com/press-release/488240/homeow...