by EvanAnderson · 2y ago · 0 comments
"At best, an air gap is a high-latency connection" -Ed Skoudis - DerbyCon 3.0
This is the network that operation Olympic Games used to get Stuxnet into the Natanz facility. Contactor laptops are a major part of that network.
The same is possible in Windows 10 and 11, but the users will revolt, if a sysadmin were to enforce such (the same users who insist on using Windows instead of a more secure system).
Can I add a little more colour here (and have worked in and designed-for very secure environments) - users will revolt if removing the USB ports makes their life more difficult. This can work if there is an effective feedback loop that makes sure the users can still do their jobs efficiently in the absence of USB ports, and corrects for them when they can't. Users won't go around something unless it gets in their way!
Partly it's to prevent leaking of company secrets, unauthorized use of corporate devices for home use, harder to track the location of data, as well as the possibility of malware.
No persistent storage, so no concerns about easily recoverable classified data sitting on desks. You could disconnect from your session and pick it up again in the other office across town, or just leave your stuff running overnight.
People don’t like windows let alone corporate deployments of windows.
My point is that, practically speaking, most companies don't have the discipline to actually keep an air gap up, long-term. You inevitably need to get data in and out of the air-gapped systems.
The "air gapped" networks I've seen end up not actually being air gaps. Real air gaps are inconvenient, so eventually somebody installs a dual-homed host or plugs the entire segment into a "dedicated interface" on a firewall. Even without that, contractors plug-in random laptops and new machines, initially connected to the Internet to load drivers / software, get plugged-in to replace old machines. The "air gap" ends up being a ship of Theseus.
I had a Customer who had DOS machines connected to old FANUC controllers. They loaded G-code off floppy diskettes. Eventually those broke and they started loading G-code over RS-232. The PCs didn't have Ethernet cards-- their serial ports were connected to Lantronix device servers. It wasn't ever really an air gap. It was a series of different degrees of "connectivity" to the outside world.