by danans · 1y ago · 0 comments
"Imagine you could open a window to get fresh air into your house and stale air out, but when you did so, most of the heat/humidity would stay in during the winter, or stay out during the summer, leaving you just the fresh air".
In terms of the effect on environment inside a house, I usually say:
"Imagine it's always a fresh-air spring day inside your house"
This is a great project. One problem with ERV/HRV systems right now is that they are very expensive niche products. While this system doesn't achieve the extremely high heat recovery efficiencies of counter-flow units, the perfect is the enemy of the good, and this seems like it could be orders of magnitude cheaper.
My entire "medium sized European suburban house" runs on a $2.5k 400m3/h unit with HEPA filters made in Lithuania - and that was the more expensive model that I can directly control over MODBUS / 0-10V signal (even turning it into a "dumb" unit). Most of the expenses were running the ducts. YMMV
It's just awesome. Every single room has fresh-smelling air and after fine tuning all my heating systems with algos implemented in Home Assistant - I'm getting ~60-100ppm over outdoor CO2, perfectly clean air, temperature within 1C of the set value, on-demand humidity extraction after showers etc. All it needs to be properly overengineered now is a bunch of dampers and per-room CO2/humidity feedback :)
I get that manufacturing the transfer plates isn't simple or cheap, but other than that one thing they're basically fans, they shouldn't cost that much.
I'd be very interested in hearing the details of this.
I have 4 systems:
- Komfovent HRV for ventilation
- NIBE F-series heat pump for floor and water heating
- Vaillant gas boiler that "supports" the heat pump
- Samsung multi-split AC units
HRV - Komfovent uses the same controllers in all of their units, so you get all the communication goodies you'd want - though it took me a long while to figure out that basic features need to be toggled on :) There are existing YAML presets for their C6/C6M controllers on HA forums. The only caveat is that if you want to feed it a virtual thermostat, you need a stuff a device simulating a 10k NTC inside of the ventilator. Otherwise it's just a single Ethernet cable.
Heat pump - I'm not exactly sure if I'm happy with NIBE, but thanks to the community the integration ended up being quite easy. I wasted a bunch of money on their MODBUS40 just to learn that you need to use a certain MODBUS address in the internal bus to make certain registries writeable (eg. thermostat values) - so I took an ESP32 with Ethernet, a galvanically isolated RS485 dongle, a 12V to 5V converter and used https://github.com/elupus/esphome-nibe. The firmware extracts my templated HA sensor's value and feeds it to the heat pump as a virtual thermostat.
Vaillant uses this weird "eBUS" protocol, there's a bunch of cheap PCBs that you can use to connect to it - I'm using https://github.com/danielkucera/esp-arduino-ebus. That's the last system that I haven't touched :)
Samsung ACs use their MIM-B19N modules installed in the outdoor units. There's some magic around enabling remote control, but once you plug their diagnostics device into their indoor units, you can flash all of them at once. I had to mess around with internal NASA addresses to have all the units appear at once.
For indoor sensors I have 3 types:
- AirGradient units measure CO2, tempeature, humidity, PMx etc. - these are mounted at ~150cm and feed the "current house temperature" template.
- I have like 8 Everything Presence One devices, powered by a custom PCB that converts 12V/24V sent over wired alarm cables to the device. They have built-in temperature, humidity and motion sensors. These are mostly installed for motion sensing and their height makes the temperature measurements quite useless.
- Everything else (and most importantly bathrooms) is done using custom ESP32-C3 devices that use SHT31 sensors to measure humidity and LD2412 for movement sensing. Also using the same adapter PCB for powering.
Thermostats are synchronized across all the devices with HA scripts. The HRV specifically uses its own wired temperature sensor to determine if it should enable heat recovery ("free cooling mode"), since its extracted air temp is always a bit lower than room temp (laziness :-)). "Current temperature" template fed to other heaters is derived from multiple room temperatures (currently using an average), with rooms "ignored" if AC is heating there (or was turned on recently). Ventilation has 2 modes set up - 20% and 80% - with the latter toggled by a bathroom humidity threshold.
There are 3 remaining things I want to set up:
- auto switching to gas heating if it's cheaper / the house is running on batteries - so far I've only imported electricity / gas prices into HA and quickly realized that I'm missing a power monitor on the heat pump circuit
- dampening of air ducts to reduce the temp drop when high humidity extraction boost gets triggered
- using more of the HRV range by auto-adjusting fan speed depending on real CO2 values - there's max 2 ppl at the house most of the time, so even at 20% the HRV is quite wasteful
That is just the HRV, not the design of the system, the ductwork, and the installation. All those add up. In new construction those costs can be shared with the regular HVAC system design, but in a retrofit its far more expensive
I think this is the one I'm using for ~200-ish sqm.
Most building codes in US/CA mandate them since about 2015, so I'm not sure how niche they are (at least in new construction).
Depending on the (air) volumes involved, ERVs can be had for under CA$ 2000:
* https://gasexperts.ca/product-category/air-exchangers/lifebr...
* https://bphsales.ca/collections/high-quality-erv-air-exchang...
HRVs for less, but it's probably worth the extra few hundred for better humidity management.
Outdoors °C -23 -15 -10 -5 0 25 30 35
After unit, °C 12,9 14,5 15,5 16,5 17,5 22,6 23,6 24,6
with indoor conditions + 22 °C, 20 % RHThe downside of this is that the high efficiency is limited to small spaces (based on the mass of your core), where counter flow units are great for entire homes.
One point often overlooked with counter flow units, is that you can place exhaust ducts in spaces that you want to purposefully remove air, like bathrooms and kitchens, while providing fresh air to places with little air movement, like closets, basements.
Regenerative core ERVs do little for fresh air circulation.
Naively allowing the air columns to thermally mix would result in the average of the inside and outside temp. So how does this do better?
Heat exchanger there is usually an extruded ceramic grid (ERV) or rolled corrugated aluminum (functions closer to HRV than ERV)
> Each OpenERV TW4 module has a very quiet pair of fans, pointed in opposite directions, and a heat exchanger in a 6 inch pipe, that goes through a wall. The hot, polluted air from inside goes out for 30 seconds, and the heat from it is stored in the heat exchanger.
> Then, the fan reverses direction, moving clean air from outdoors to the indoors. On it's way in, it picks up that heat from the heat exchanger. This type of heat exchanger is called a regenerative heat exchanger, or less commonly, a regenerator. The kind shown in the video is a recuperative type, not regenerative. Recuperative types are what most people think of, consisting of a thin layer of material that separates two gas streams. Regenerative heat exchangers are different. They briefly store the energy while air flows in one direction, then release it when the air flow reverses.
> The OpenERV TW4 modules are made to always work in pairs. One always sucks air while the other blows air, synchronized over WiFi. This should be done, or hot air would be pushed out from the building through the walls during the ingress phase, causing heat loss.
CO2 scrubbing would be better than nothing, but it's really expensive and won't improve other metrics like TVOC
If you are doing that level of renovation is is probably better to just tear down the house and rebuild. The costs will be similar and there are a lot of other things people demand of a new house layout that cannot be retrofitted in the old shell. Often the law will not allow this and so you are forced to renovate just to keep some now illegal feature that is worth keeping, but otherwise a tear down would be better.
* It's a rowhouse, so there are two party walls on either side.
* Brick.
* The front and back walls are half the length (15') of the party walls.
* The house is small, a footprint of 450 sq ft.
* The renovation will extend the back roof line (pitched roof, front to back).
* The attic (with extended roof) will be renovated with a bedroom and 3/4 bath, plus storage and mechanical.
* Plumbing will be replaced.
* Gas boiler (with radiators) and existing central A/C will be replaced with heat pump.
* We'll be out of the house for months.
* It's in a historic district so it can't be torn down.
* Fortunately most of the windows have been replaced before the historic preservation office started cracking down on replacements. We have light-blocking hex blinds that insulate them nicely at night.
* I will try to sneak in a new front door that's the same design as the old one, and fix up the jambs and sill.
* Historically DC is still more heat dominated than cooling dominated, but climate change is tilting the balance. It may be hard to fight the stack effect in the winter but in the summer I hope to run the house at positive pressure. It's when the A/C's been going for days that the air in the house seems stale.
* Even though there's very little insulation today in the attic (just cellulose strewn between joists), it's not expensive to heat or cool, because it's such a small house.
* I care more about the ERV as a luxury good than as a cost effective appliance. I'm quite sure the cost of it will be negligible when compared to everything else in the reno (we're doing the kitchen, too).
Although the cost will be insane, I expect we'll come close to breaking even on value added to the property, given the neighborhood we're in.
You have also touched on why I oppose historical districts. Historical buildings should be something people are required to learn about in their history class.
Use a qualified professional. Get multiple inputs.
It will cost money, and more money as you approach perfection, but it is doable.
There's only so much temperature gradient these setups can handle economically, and it's quite possible that the hot LA summers combined with the cool AC air are too much for such an installation not to leak energy at an unacceptable rate.
Then again, just like with ACs that also serve as heat pumps, it could just be a matter of not enough people (or professionals) knowing about these installations to make it viable to build a business around them.
Type in HRV system in to your preferred search provider and hit the shopping tab.
Here in Australia they range from about 1500 Antipodean Dineros for a single room through-wall mounted systems, and around 5500 upward for a centralised unit. Plus installation costs, but HVAC install is one of my paid activities, so I mostly don’t pay that part.
NB heat pump is a more accurate term for refrigeration type air conditioners, as in cooling mode they’re ‘pumping’ the heat out of the inside environment and rejecting it outside.
But have you heard about brown?
If you call a random HVAC company, they may not want to deal with "fussy clients" that want something "fancy" like an HRV/ERV. Best to look at folks that perhaps try to adhere to building science more. A quick search for the LA area:
* https://www.jmsacandheating.com/indoor-air-quality/heat-ener...
* https://www.aircomfortexperts.com/additional-products/ervs/
* https://www.azaircond.com/indoor-air-quality/energy-recovery...
* https://www.socalclimatecontrol.com/ervs-and-hrvs-energy-eff...
Or do a dealer search from a manufacturer, e.g.,:
* https://broan-nutone.com/en-us/home/dealer-locator
> Is there a particular climate these are suited for?
Any climate. Modern ones can even handle IECC Zones 6 and 7:
Getting rid of humidity in winter is the main reason why you want to bring fresh air in a house though!
Bringing in cold air at 50% humidity, then warming it up to room temp makes the humidity fall, leading to dryer air indoors than comfortable.
There's a problem with “dumb” ventilation systems though: they can't really adapt to big variations in outdoor conditions, and as such they tend to such way too much air out of your house than needed during the cold days (and it also tend to be designed to suck cold air into dry room first, and get out from wet rooms, when you want it the other way round when it's very cold).
In the hot and humid summer you're definitely trying to reduce indoor humidity.
But in the winter when it's bone-dry? A hot shower barely makes a difference.
I keep two humidifiers running all winter long just to bring indoor humidity up to 35% or 40% where it's healthy.
Otherwise it often goes down to 15% or even 10% on cold winter days, which is terribly unhealthy.
They say they let cold air in during the winter because they want to lower the humidity.
Then you say that, if you let cold air in (and then let it heat back up again) then you end up with lower humidity.
The only thing you might disagree on is exactly what humidity you would like inside your house. But that's subjective. (As it happens, I agree with them: I often find it too humid inside during the winter, because I've restricted airflow to keep the heat in.)
Aren't you missing a zero of something? Because 900ppm isn't “very poorly ventilated”.
I notice I'm not as mentally focused once it gets to 800 or so.
I have a CO2 monitor to keep it below 600 for productivity and concentration.
Remember, fresh air is around 420.
Possibly just different terms used in different countries where the humidity is a bigger problem (very hot and/or very cold outside air).
This current OpenERV product appears to use dessicants for this purpose but might be an optional add-on?
This is to avoid energy loss that would occur when moisture condenses (i.e. the latent heat) by using an adsorbant material to capture moisture before it escapes, or a membrane that allows moisture in the outbound flow to pass to the inbound flow.
Really a lot of our older homes shoud be retrofitted with a MVHR unit to help things as ventelation is awful in most houses. I'm actually quite surprised a lot of landlords in the UK don't do it as theres always a fight between them and their tenants who don't necesserily want to leave a window open all day in the winter to stop mold.
I think it basically trickles in cold (and therefore drier) air into a central space to reduce humidity, like an (slower, quieter) extractor fan in reverse.
Seems a bit of a conflict of interest still, especially if the tenant is paying for heating.