They are rated 90% recovery at low speed. Today it's 11C 75%RH outside, 18C 65%RH inside, at low speed (15m3/h rated at 1.2W) there's barely a difference: 17.8-17.9C air intake temperature. They keep the air noticeably fresh, drier and also keep the CO2 down (<600ppm right now). I'm running them below the "recommended" 50% air-change per hour (ACH about 35%), and boost when needed.
There's a recuperative ducted type in the attic for the first floor, when I checked last month it was 4C outside, 18C at the outlet vent, and 17C at the inlet vents. That runs at 50% ACH.
The reasoning for the paired up window model isn't obvious, maybe a simple increase in capacity. The website is quite clear you need a push/pull pair to be efficient, and an immediately adjacent such pair is not going to work so well.