by NavinF · 1y ago · 0 comments
I wonder if it'd be worth having three TW4 modules with sorbent on only one of them. That way you can control humidity better by choosing 2 of the 3 to use at a time. Eg after a long shower you might wanna discard water vapor for an hour
What's the significance of the model numbers 4 and 12?
The numbers are the number of versions before it stabilized, so 12 tries for the window mount, 4 for the through wall. It took a while.