If there’s a fire or similar problem the fire handles will cut off fuel without the normal shutdown procedure, but the normal switches only need to be used at idle thrust.
I wonder if Airbus has this logic, since their philosophy is to override the pilot commands if they’d endanger the aircraft (which has its own issues of course) where’s Boeing will alert the pilots and still perform the action. I don’t have access to that information.
As another commenter said the Airbus engine start/stop controls are located behind the thrust levers, and according to the A350 operations manual which I got my hands on there are two conditions required for the FADEC to command engine shut down: Run switch to off, thrust lever to idle.
So if that's correct on an Airbus aircraft you can't just switch off the engines when they're commanded to produce thrust. This also seems to be backed up by the difference in the guards for those controls in the Airbus cockpits.