110 points · by the_arun · 1y ago · 48 comments
(Nonetheless impressive, and multi-core fiber seems to be maturing as technology.)
How come with a LAG group on ethernet, I can get "more total bandwidth", but any single TCP flow is limited to the max speed of one of the LAG Components (gigabit lets say), but then these guys are somehow combining multiple fibers into an overall faster stream? What gives? Even round robin mode on LAG groups doesn't do that.
What are they doing differently and why can't we do that?
1. The lengths of all wires are meticulously matched so that signals arrive at the same time. Then the hardware simply assumes that the bits coming off each wire are in sequence by wire order. This is done in computers for high speed interfaces such as memory or graphics. If you have ever seen squiggly traces on a PCB going to a high speed device, they were done to get the lengths to be exactly the same so the signals arrive at the same time across each. This is how data transfers from dual channel DDR4 RAM where 64 bits are received simultaneously occur without reordering bits.
2. The lengths of wires are not matched and may be of different lengths up to some tolerance. Deskew buffers then are used to emulate matched lengths. In the case of twisted pair Ethernet, the wire pairs are not equal length because the twist rates vary to avoid interference from having the same twist rates. The result is the Ethernet PHY must implement a deskew buffer to compensate for the mismatched lengths and present the illusion of the wire lengths being matched. This is part of the Ethernet standard and likely applies to Ethernet over fiber too. The IEEE has a pdf talking about this on 800 Gb/sec Ethernet:
https://www.ieee802.org/3/df/public/23_01/0130/ran_3df_03_23...
LAG was never intended to have the sequence in which data is sent be preserved, so no effort was made to enable that in the standard.
That said, you would get a better answer from an electrical engineer, especially one that builds networking components.
You're (incorrectly) assuming they're doing Ethernet/IP in that test setup. They aren't (this is implied by the results section discussing various FEC, which is below even Ethernet framing), so it's just a petabit of raw layer 1 bandwidth.
How do these guys get the data in order and we dont?
LAGs stripe traffic across links at the packet level, whereas QSFP/OSFP lanes do so at the bit level.
Different sized packets on different LAG links will take different amounts of time to transmit. So when striping bits, you effectively have a single ordered queue, whereas when striping packets across links, there are multiple independent queues.
What you do with it at the higher layers is entirely up to you.
But, ethernet could totally do that, by essentially demuxing the parts of an individual packet and sending them in parallel across a bunch of links, and remuxing them at the other end. I'm not aware of anyone having bothered to implement it.
I would guesstimate that if you try to run it live, the receiver [or rather its DSPs] would consume >100W of power, maybe even >1000W. (These things evolve & improve though.)
(Also, a kilowatt for the receiver is entirely acceptable for a submarine cable.)
[1] https://www.arista.com/assets/data/pdf/Datasheets/400ZR_DCI_...
The 38kW is not a very high number btw, the switches at the end points of submarine links are quite a bit more power hungry already.
[but now that I think about it… I think my estimate is indeed too low; I was assuming commonplace transceivers for the unit factor, i.e. ≤1Tb; but a petabit on 19 cores is still 53Tb per core…]
¹ note the setup in this paper has separate amplifiers in 86.1km steps, so the transmitter doesn't need to be particularly high powered.
I mean, it’s a shitload more power than a simple media converter that takes in fiber and outputs to a RJ-45 but not all that much compared to other commercial electrical loads. This Eaton/Tripplite unit draws ~40W at 120V - https://tripplite.eaton.com/gigabit-multimode-fiber-to-ether...
A smallish commercial heat pump/CRAC unit (~12kW) can handle the cooling requirements (assuming a COP of 3)
Sumitomo sells a lot of fusion splicers at very high margins. It is in their best interest to introduce new types of fibre that requires customers to buy new and more expensive fusion splicers. Any fibre built in this way will need rotational alignment that the existing fusion splicers used in telecom do not do (they only align the cores horizontally, vertically and by the gap between the ends). Maybe they can build ribbon fibres that have the required alignment provided by the structure of the ribbon, but I think that is unlikely.
Given that it does not interoperate with any existing cables or splicers, the only place this kind of cable is likely to see deployment in the near term is in undersea cables where the cost of the glass is completely insignificant compared to everything that goes around it and the increased capacity is useful. Terrestrial telecom networks just aren't under the kind of pressure needed to justify the incompatibility with existing fibre optic cables. Data centers are another possibility when they can figure out how to produce the optics at a reasonable cost.
Additionally, the setup uses optical amplifiers in 86.1km steps.
Both of these things put this squarely in submarine-cable-only space. Total cable size is in fact a problem in that space, 4-core claddings are roughly state of the art there, but there's enough room for those to be non-coupled. Higher core counts requires research like this.
Either way you'd be terminating a 19-core setup like this with an OEO (and probably FlexE and/or an OTN solution) both ends.