by aetherspawn · 1y ago · 0 comments
If the packs are not perfectly balanced, the batteries just short into each other and explode, and BMS can’t do anything because there isn’t any per-cell switch (cost).
It’s not just a matter of balancing voltage either, the cell profiles (voltage vs SOC) have to be the same otherwise you end up with 1 cell doing all the work. Simply put, when you mix and match cells of different brands, models, or even ages, they don’t integrate evenly. This results in a few or even just 1 cell doing a majority of the work during both charge and discharge, maybe 10x higher than its safety rating, guaranteed fire…
Also end-user is expected to do the math and input the battery’s total current rating into the motor controller? Yeah, nah, a hundred kids will think it’s cool to set this too high and set themselves and people around them on fire.
We are also looking for bike-shop owners who want to train on our batteries (it can be learned in one hour or so) to get a new revenue stream by offering to repair and assemble our batteries!
Plus, once you sent your battery, they either discard it which is not ideal for the environment, or try to remanufacture it, which is very dangerous when it's done on a battery which wasn't designed for it, like ours
As long as the controller is made sufficiently conservative, there is no fundamental problem: you limit the current according to the cell that heats the fastest and shut down once one cell is near depletion.
Maybe they have even gone a more aggressive route and build a balancing circuit that can route significant current around a low-capacity cell. Or maybe just charging logic to keep as many cells as possible in the 20-80 regime if they will be limited by low-capacity members anyway. There are so many options here.
I am not enough of an expert to know if all this could work, but its got to be better than replacing an entire pack at a time to be worth trying
Most people aren't aware of how dangerous it is to try to "revive" a cell that got too low so this technology definitely comes with significant risks for user error.
So yes, the net current is supposed to be okay, but it’s not, and rather than responding individually to all the other comments I may as well mention that no amount of temperature monitoring will fix this. Temperature sensors don’t detect internal cell stresses that cause spontaneous failures.