by fulafel · 1y ago · 0 comments
You'd think water would be easier to exchange heat with since it can slosh around the heat exchanger elements in the tank more easily. Which should translate to lower costs since you don't need as many exchanger structures in the medium.
Any guesses for the motivation in using sand? Maybe it's that you can heat it over 100C? But then big heat differences to the environment mean high conductive/radiation losses or heavier insulation requirements.
Insulation isn't such an issue with sand because sand itself is fairly good insulator and obviously doesn't convect. 1m of sand is about the same as 10cm of air. 500C through 1m of sand if roughly 125W/m². Which isn't nothing but it's also 7m from the center to the edge, and the efficiencies only improve the bigger you make the silo.
Presumably they have a double-skin gap and other external insulation too. As the Icelandic hot water pipe systems show, which drop only a few degrees C over hundreds of kilometres of pipe (and thus a gigantic surface area to volume ratio), you can have really quite good insulation if you have space to make it thick.
The hassle of handling hot water is also presumably why they use hot air rather than water as a working fluid for heating the sand in the first place. The worst case if you spring a leak in a heat-transfer tube inside the tank is that a bit of air escapes. Leaking super-heated high-pressure water or steam into the (unpressurised) tank would be a much larger problem, and unloading up to 2000 tonnes of hot, damp, sand to plug it would be operationally very annoying if nothing else.
"Rock, sand and concrete has a heat capacity about one third of water's. On the other hand, concrete can be heated to much higher temperatures (1200 °C) by for example electrical heating and therefore has a much higher overall volumetric capacity."
and
"Polar Night Energy installed a thermal battery in Finland that stores heat in a mass of sand. It was expected to reduce carbon emissions from the local heating network by as much as 70%. It is about 42 ft (13 m) tall and 50 ft (15 m) wide. It can store 100 MWh, with a round trip efficiency of 90%. Temperatures reach 1,112 ºF (600 ºC). The heat transfer medium is air, which can reach temperatures of 752 ºF (400 ºC) – can produce steam for industrial processes, or it can supply district heating using a heat exchanger."
If I add some fixed amount heat to some fixed volume of water, it might rise by 1℃, while the same volume of concrete rises by 3℃. And by the same logic, on release, that fixed volume of water dropping by 1℃ releases 3x as much heat as when that fixed volume of concrete drops by 1℃.
So if you can max heat water to 100℃, and max heat concrete to 1200℃, and on release you let it go to 10℃ (probably the range is less in practice), then the water can drop 90℃ and the concrete 1190℃, so even if the water releases 3x the amount of heat per ℃, the water just releases 270 (per volume) while the concrete releases 1190 (per volume)
Also, looking at how hot water could theoretically get (decomposes between 2200-3300C), it looks like 1200C is an interesting limit. Above that and you get safety(practical) and cost issues with every material I could find (common salts, pure elements).
Sand just makes sense! Though, don't ever youtube sand battery.
Huh? I just get stuff related to this article?
in any case, how would you transport high temperatures to the industrial sites? water boils at 100° and few liquids boil above 400°. most liquids will be impractical due to cost or safety (combustibility, toxicity…).
Now, in practice you _probably_ don't want to do this, because, in this case, you have district heating demand, which is a far more efficient use of the power.
Square cube scaling means that insulation becomes trivial in total costs as you scale the installation up. Something that's convenient for a single household would probably be too hard to insulate, but this thing holds 2000t of sand.
[0] https://www.engineeringtoolbox.com/water-vapor-saturation-pr...
So quite a bang - allegedly this is 200lb, so about the same: https://www.youtube.com/watch?v=ZDgvar7ON54
Even the lower range doesn't leave much delta in best case of boiling water. So you would need some type of heat pumps instead much simpler heat exchangers. So that is also one cost optimization.
And of course it's still a win if you can heat the return water half of the way to spec with the battery, it's not necessary to have the battery heat it all the way to the plant outgoing temp.
District heating systems have been happily using ~90C water based heat batteries for a long time.
In the end it comes to balance with cost, simplicity, capacity and such. Heat pumps do allow extracting heat from colder storage medium. But on other hand electric heating elements and heat exchangers are very much simpler and cheaper.
But yes heat pumps are used in some parts as well in DH.
For those who haven't seen it there is a famous Mark Rober video: https://www.youtube.com/watch?v=My4RA5I0FKs
If it were pure silica sand, you could presumably get even hotter before anything changes chemically, but at the that point you start having materials issues with metal parts of the system: 500C is about the limit for ordinary steels to lose strength (and many are less than that - heat effects can often start at 300C).
That said in practice, at scale... before filling up your storage tank you'd probably need to pre-heat it once to remove all moisture and volatile gunk adsorbed onto the sand.