by crazygringo · 1y ago · 0 comments
That's why fresh air is key. Crack a window or two open. Buy an air monitor that monitors CO2 (good proxy for overall freshness), VOCs (sometimes these build up much faster than CO2), and PM2.5.
If CO2 or VOCs are high, open windows more. If PM2.5 is high and coming from outdoors, turn on an air filter.
Yes, this means your heating and cooling bill will be a bit higher. But for your health and concentration, it's worth it.
The cheapest real ones I've found are on the order of ~$150
They all assume that they will be exposed to atmospheric concentrations of CO2 at least once a week.
So many seem to rely on automatic ‘calibration’ - which just seems to consist of “let’s assume the lowest sensor readings of the last while correlate to baseline atmospheric CO2”.
For a meter that’s never taken outside, this is obviously going to mean it’s reading too low all the time after a few ‘calibration’ cycles. And, worse, it's likely to be more wrong in less well ventilated spaces.
You calibrate it by setting it outside for a bit to establish the baseline and then bring it inside. The detected CO2 level noticeably tracks with the number of people in the living room in which it is located and whether outside air is being pulled in, either due to the furnace or having multiple windows open.
We do not use the app, so I can't comment on that. And my only complaint is that it has to be plugged in otherwise it runs out of power in an hour or two.
Hackers may prefer other options.
The bigger challenge is with my windows open, my heating just can't even keep up! It'll be maxed out and only 18c.
I do the German-style luften twice a day, but if our interiors are just absorbing the compounds and releasing it when the windows are shut, then that's not even going to help much.
https://natural-resources.canada.ca/stories/spotlight-energy...
I have been investigating easier to retrofit decentralised MVHR systems such as the Prana Recuperator, Ventaxia Tempra and the Blauberg Vento. They can be noisy (not a problem for me, I don't mind noise) and quite expensive as you have to fit a number of units in different rooms, but still easier than retrofitting ducting.
https://ambientweather.com/indoor-wireless-air-quality-monit...
We have low-voc foam in the attic, which outgasses voc’s slowly and constantly. (They measure voc release at application time, not over the product lifetime).
I started actively venting the attic a two months ago. The whole house reeked of foam for a week or so whenever the windows were closed.
It’s fallen off a lot, even though the attic foam is 5 years old.
I think the sponge analogy is correct. If the house is sealed, the VOCs accumulate in the atmosphere, and are reabsorbed into the foam at the rate they are released into the air.
If you leave the house completely open, the outgassing will not be offset by reabsorption.
I think the CO2 in our place accumulates faster than the VOCs I can smell, so opening the windows when the meter tells us to keeps the net rate of outgassing high, and the indoor pollution low. It seems like the outgassing is slowing down now.
I really should get some VOC meters.
Das ist nicht genug und klingt ehrlich gesagt grauslich.
Not German approved.
They're trying to heat it.
I’d like to do a custom build like you so the fan speeds are variable.
As an aside, I open up my window, but sometimes smokers decide to take a break outside and...well. Other times, I have neighbors barbecuing.
If I don't shut the windows quickly I've just replaced stale and somewhat harmful air with oxygenated and definitely harmful air.
I have a purple air sensor outside. One day I'll get around to making the air exchanger smart enough to turn off when the smoke from fires makes the air outside worse than inside, it turn off the air exchanger when inside air is good enough, etc.
Not even necessarily. People these days are accustomed to keeping their homes at comfortable T-shirt temps even in the dead of winter, but if you dress appropriately for the season you can drop your indoor temperatures 20F or more from what people normally set the thermostat to while still maintaining a safe margin to keep your pipes from freezing.
I mostly solve any issues with VOC by "Stosslueften", but if that's not enough because the air quality outside is too bad, a CR box is an effective, easy to build and almost perfectly silent design, especially if you do it with decent quality pc fans.
Much better than cracking a window is the use of ERVs (energy recovery ventilators) and air filters on the incoming air.
An ERV is a fairly simple device that exchanges air with the outside while mitigating the loss of energy and humidity.
Any modern home build likely has an ERV as part of the design, but it’s not like they can’t be retrofitted, and I’ve even seen some DIY-friendly window unit ERVs (but I’ve never heard if those are any good).
Sounds very country dependent. I really doubt it's true here in the UK. But then, UK housing is just garbage all around unless you build something custom and put a lot of money and attention into it.
It's easily the favourite thing in my home. It filters the outdoor air, reducing pollen and mosquitoes. It keeps out excess moisture in summer. I don't have to open a window when it's cold. It automatically goes into overdrive after a particularly steamy shower. It's great.
Cracking a window is also costly, since it directly raises your heating and cooling bills. It's just an "invisible" cost that's easy for some people to ignore since it's hard to directly measure. An ERV pays for itself over time, so it's more a question of whether you can afford to just crack a window?
Living in an apartment makes this difficult because your landlord may not let you improve this situation, but just ignoring the cost of opening a window doesn't make the cost go away.
If you live somewhere uninhabitable like Texas, change heating for cooling.
A couple examples I see on Google. I'm not advocating for any of these, because I have no idea if they are any good, but I see no technical reason an ERV couldn't work as a window unit. Maybe it's an underserved market and someone should make a business out of that.
A much more DIY example that's probably closer to what you were talking about with "hacking together" a solution: https://www.mychemicalfreehouse.net/2023/10/window-mounted-p...
Yes you have to take into account running an air filter for PM2.5, closing the window while a truck is idling outside, running your humidifier or dehumidifier if you want.
But you need fresh air coming in somehow, at a certain rate. There's no way around it. Pollution in terms of VOC's, and CO2, is always higher indoors than outdoors, because things indoor generate it and don't remove it.
It's not usually the only option. Installing an ERV is an option for the more than half of the population that owns their own property in the US, and an ERV will save money and pay for itself compared to opening your windows, in addition to the other benefits.
For renters, that's where the window units I mentioned come in, but there aren't as many options there as I would hope yet. If people don't ask for ERVs en masse, then apartments won't offer ERVs as a benefit to attract tenants unless they are legally required. Helping people understand that options exist seems like the first step to changing things. Ideally, even window-unit ERVs wouldn't be the only option for renters. Nearly 90% of households in the US have air conditioning now (which I believe includes rentals), because people asked for air conditioning and were willing to pay for it. ERVs have the added benefit that they don't just make things better, but they should pay for themselves in energy savings too. Maybe I'm too optimistic. I believe the 2024 IECC building codes make ERVs mandatory in new construction in climate zones 6 through 8, as one example of a change that is coming.
My problem with this advice is not that it's difficult to measure pollution levels (it really isn't), but that there's no "fresh air" outside for many of us. In many parts of the world, the air is significantly worse outside than inside even without running an air purifier (and with a purifier the difference in particulate levels can run into 100× or more during winter).
Some years ago I looked at the few papers that measured the difference in gaseous pollutants (like NO2 and SO2) inside and outside with windows open and windows closed, and for some reason closed windows do provide limited protection against them. Nobody really understands why AFAIK, it shouldn't work that way since they're mixed with air in a gaseous mixture from which they can't be filtered out without a specialized chemical filter, but it does help.
No surprise. A lot of homes are still being heated by combustion. Gas heating is relatively clean if the burners are properly maintained, oil burners are a hit and miss, but everything else... wood pellets are often declared as the "green" alternative, but that's only valid for CO2 (and even there, the actual benefit for the climate is massively debated) - these things spew an awful lot of particulate emissions, brick-wood ovens are even worse, especially when people illegally throw in too humid firewood or, worse, garbage that has no business being incinerated outside of an industrial high temperature facility with proper exhaust stack treatments.
Unfortunately, as you say, in many parts of the world people are too poor to afford proper heating fuel sources, and it's costing them and their countries so much productivity and money in the long run... and in developed countries, there still are a sizable amount of people who have no idea how to properly heat their ovens, how to prepare their firewood or that just outright skirt garbage disposal fees. Jörg Kachelmann, founder of the weather service Meteomedia, has extensively written about that topic in the past [1] and keeps ranting on social media about it under #holzofengate.
[1] https://www.t-online.de/nachrichten/panorama/id_84671908/kac...
Maybe my numbers should be 100 and 10,000, but it doesn't matter, I know when I need to turn the air exchanger on turbo and when we are back to "normal".