by WaitWaitWha · 1y ago · 0 comments
> Once in place, people simply plug a micro-inverter into an available wall outlet.
later
>Gründinger and experts at the German Solar Industry Association noted that the devices don’t generate enough power to strain the grid, and their standardized design and safety features allow them to integrate into balconies smoothly and easily.
This seem to talk to the safety of the grid and the balcony. What is done when electricians power down the apartment or worse, the building to work on something? The wires remain energized despite proper distribution panel shut down. Do these setups have auto shut off if they see no other power on the plug they are on? what if it is the building, wouldn't other panels still energize the wires, so they would not shut down? Just asking, as my personal experience is quite hair raising and crispy when it comes to inappropriately de-energized circuits. ;)
This is a newbie question, and I look forward to learning how it's more complex than this.
Simple grid-tied microinverters are completely incapable of doing anything without a grid to work with, and this is necessary: A non-synchronized AC generation source can't survive long before becoming an expensive puff of smoke instead.
Anti-islanding is an actual feature that is also inherent in the design of grid-tied inverters: When there is nothing for them to sync to, they output nothing.
However, there’s a problem in addition to electrocuting utility workers (the ones around here assume islanding during outages, so that’s less of an issue now).
Say you plug the microinverter into a 16A 120V outlet in the US, and the power goes out while you’re running a 240V 40A clothes dryer. The island is definitely going to collapse at that point, and might do bad stuff on the way down.
Yes. This is Germany we are talking here. I doubt any other country has higher (and more annoying) safety standards.
https://www.heise.de/news/RelayGate-Deye-Solar-Microinverter...
They only had a software implementation and were forced to send all customers in Germany a free relay dongle to ensure safety.
Well, I hope that any competent electrician will measure if there's still any voltage on the circuits after pulling the breakers.