by cfu28 · 1y ago · 0 comments
It blocks the system with a demanded action, but doesn't even show you what triggered the alert condition? I would completely expect a "List of conditions that suspect sepsis" and get those details up front and center.
I'd be putting in medical records "Due to software popping up an un-dismissable sepsis screen that does not show details, I dismissed it due to needing the data it was flagged on".
Lemee guess? Epic?
You’ll get something like “sepsis criteria triggered by wbc 13, cr 1.5, hr 101, rr 22.” And that’s it - usually in the middle of a night on a new patient I just got a page for. Can’t open documentation to see the patients med history. It’s ridiculous. I’m not using Epic but I am using a major EMR.
To be fair I’ve written almost exactly what you mentioned out of sheer frustration once or twice but it’s not ideal
Yes, in almost every case, the default "popup" GUI library call is also a modal dialog. You cannot access anything else, anywhere else, in the entire program (even if the program had multiple separate windows open). All you can do is read the dialog's text, and hit the "ok" button to dismiss it (or pick from one of a set of "buttons" that are shown on the popup to dismiss it).
The worst ones also do a global grab, with the result that you can't even switch away to another unrelated application on the system without first "interacting" with and dismissing the popup.
To see the version that is built into Javascript in the browser, put the following into the URL field of a new bookmark, and save the new bookmark.
javascript:(function(){alert("hello");})();
Then, while here on HN (or anywhere else), click that new bookmark you just made, which will pop up the default built in Javascript alert box, and try to interact with the rest of the page it pops up in front of.My older car regularly hallucinates an incoming frontend collision and takes over the speedometer with a flashing red/black screen.
The new one (Kia) overrides the steering and forces the car to depart the lane (usually over double yellow lines).
If the alert regularly produces false positives then such behavior (and the behaviors of these EMRs) should open the vendor to civil and criminal liability. The courts should just assume the behavior will lead to loss of life, in the same way as discharging a firearm randomly in the city might.
It probably makes sense to have a short grace period to push a patch. Maybe one week after 0.1% of users complain?
What, by your estimation, would be the better user experience for alerting the imminently life threatening situation?
It sounds like a signal to noise ratio with false positives, but IMO I'd rather a provider be at least given the time to pause and consider the diagnosis. I'm not sure about the optimal way to do it.