by blahedo · 1y ago · 0 comments
I live in the mid-Atlantic (US) climate zone, where it's certainly not as cold as the north but definitely goes well below freezing regularly for several months of the year. The place I've lived for 15 years had a heat pump and a (oil) boiler with radiators, and when it was below 40°F (~5°C) I had to switch to the radiators. It's because it's old, everybody told me, modern heat pumps are better! So last year when both systems needed repairs at the same time, I not-entirely-willingly switched to a brand-new 2024-model heat pump. It absolutely could not keep up when the temperature was freezing until they came back and installed resistive heat strips for low temperature---these seem to be a fancy version of the heating elements in a space heater or a toaster. They do not seem to be particularly efficient. And to the extent that my "heat pump system" does now more or less keep the house adequately warm, if not as comfortable as the radiators always could, it's not solely due to the heat pump, but the other stuff they had to put in because the heat pump couldn't keep up.
My experience is far from unique. Maybe it's that they only install the good ones in farther-north locations! Maybe it's that the good ones are just way more expensive! I'm perfectly prepared to believe the factual statements about the physics and the tech. But if we're talking about perception and "why aren't more people looking to install heat pumps", it's because lots of people have experiences like the above, and that is what the industry needs to work on.
All this to say: if your pump can't handle +5°c, I wonder if you got scammed or if there are other factors at play? Is your house insulated at all? Do you keep your windows open throughout winter? Your experience is so different from mine it's hard to believe we're even talking about the same technology!
That contrasts quite a bit with Swedish home standards, which have long been built more air-tight and with considerably better insulated even if they're of comparable age. This has been true for decades, became even more stark in the 1980s, and likely remains very different on the balance: https://www.aceee.org/files/proceedings/1984/data/papers/SS8...
Also, as noted, I'm sure part of it is that they gave me a heat pump that's rated to 5°C or whatever instead of -15. Probably because they expect that everyone around here has a backup heating system, and it doesn't get Sweden-cold (or Chicago-cold, for that matter) in this area. Cool cool, but that just reinforces the message that heat pumps can't hack it and if you're buying a heat pump system you really need to also buy a second system—which may not be entirely true but there's other people on this very thread with a kind of dismissive "everyone knows" attitude regarding backup heating that fundamentally undermines the original message (which was my whole point).
I realise it might sound hollow to say that I don't think you need a backup, given that I myself actually do have a backup in the form of a fireplace. Well, my house is old, even by Swedish standards. A letter I found in a jar under the floor when I was redoing the ground insulation a couple of years back claims the house was built in 1840. I have of course updated the fireplace to be compliant with modern fire safety standards, but the original construction predates heatpumps by some margin. If not for that I probably wouldn't have had a backup. I might have gotten a second pump to help with my chilly office, but that's really more about my house being too big for the pump I have than it is about heatpumps not being able to "hack it".
It depends primarily on your electricity and methane prices. In Ontario, Canada, electricity is cheap enough that heat pumps are cheaper than methane on all but the very coldest days, even if your home insulation is older than 1980 standards.
When was the heat pump manufactured? Mitsubishi, for one, publishes data were they have 100% heating capacity at -15C, which some models being 100% at -20C and -23C:
* https://www.mitsubishielectric.ca/en/hvac/home-owners/zuba
There's a website for cold climate air-source heat pumps (ccASHPs), that has performance data down to (at least) 5F/-15C:
* https://neep.org/heating-electrification/ccashp-specificatio...
OEMs can optionally have publish data on "Lowest Cataloged Temperature" if it's below 5F/-15C.
Also: how (air) leaky is your house? how much insulation? For a lot of folks dealing with those two things would be more cost effective than anything.
As it stands, even if you are heating with "cheap" methane (née 'natural') gas, propane, or oil, you're throwing money out the window by letting the heat out in winter. (And the heat in / cold out in the summer.)
Heat pumps work, but they aren't nearly as _pleasant_. You can write essays about the efficiency of heat pumps, how lukewarm air works just fine to warm the house, how heat pumps are great _most of the time_ and you can supplement with space heaters or whatever when they fall short... But as long as furnaces are accessible and affordable, an awful lot of people are going to choose to have nice warm heat that is always going to be nice and warm regardless of the outside temperature.
In my experience at least with relatively modern heat pumps (roughly 2000 and newer) it doesn't matter that much when outside temps are above freezing. But it quickly starts to become noticeable as temps drop into the 20s.
The mistake people make is assuming a heat pump can do everything by itself anywhere in any climate. If you have cold winters, you need a dedicated furnace to supplement the heat pump.
I say supplement because while an electric furnace is near 100% efficient at turning electricity into heat, a heat pump can be far more than 100% efficient. And that's the crucial detail: a heat pump can give you more heat per Watt than a resistive heater when outside temperatures are warm enough.
Im in NY, 6 heads across 3 floors with 2 heads per outdoor unit. 2500sf covered.
Mitsubishi h2i (i think im on my phone). Get plenty warm in the winter as my sole heat source. I could have gotten smaller outdoor units and had resistive backup but I didn’t want that.
(disclosure/transparency I'm the founder of Quilt, a ductless heat pump manufacturer)
It seems to me that you're helping to close the loop on some of the quality concerns that the parent commenter has. Inappropriate sizing/installation and poor product selection seem like common issues from HVAC installers that aren't particularly well versed on heat pumps.
Wishing you continued success, and that hopefully it'll be available in Canada at some point! And also I remember you from the Scala meetup in Vancouver :)
We'll have a partner in Nanaimo very soon as well.
In this case, contractor should have advised the heat pump would not keep up and recommended a different solution.
That they came back and added resistive heating suggests your contractor may not have been too worried about sizing the system correctly in the first place.
This is why contractor & homeowner education are so so so important to get this energy transition right! I always hate to see reviews like this from folks that have installed a heat pump.
It’s almost always a combo of poorly communicated expectations & installer issues.
A few thoughts…
1) “Air doesn’t come out hot” is a common complaint. It’s by design! You don’t need scalding hot air to have a comfortable space. If you’re targeting a 70 degree setpoint, even 80 degree air will get you there eventually. Heat pumps work best when you let them run - they soak the space with heat.
Your furniture, walls, floors all equalize in temp and radiate heat. A totally different form of comfort than standing in front of a vent that blows hot air at you for 5 minutes and then shuts off!
2) AC doesn’t reduce humidity as well. Unfortunately, this is a classic problem with oversized heat pumps. The key to dehumidification is runtime. A well sized system will run for longer, which will pull the humidity out of the space. If the system is too big, it’ll cycle on and off & not dehumidify.
Your contractor should be do load sizing calculations to determine the size of your heat pump, not using rules of thumb or matching the size of the existing equipment! The very best contractors use performance based load calcs, where they look at your past energy bills to size your new system.
3) Supplemental heat runs a lot - this SUCKS. Electric resistance heat is really expensive to run. It really should be something that comes on for emergencies, if ever. Definitely not regularly.
Many contractors set the temperature where the supplemental heat kicks on way too high. You could be running the heat pump (which is way more efficient) to a much lower temperature, but it’ll switch to expensive aux heat instead. Fortunately, the fix to this is simple - just a thermostat setting.
In other cases, they’ll install a cheaper mild climate heat pump in a truly cold climate. This might save money up front, but it’ll kill you in operating costs when you’re paying 4x as much as you could be in the middle of winter to heat your home. The lowest bid could cost you in the long run!
PS - this homeowner later chimed in that swapping the thermostat helped reduce their electricity bill roughly $30/month! A lot of heat pump issues actually boil down to a poorly configured system. Choosing the right contractor is probably the single most important decision you'll make when you get a heat pump installed.
I went with a vendor who did the math and sized accordingly and my system works great - great comfort year round and very low energy usage.
Try to get an install for $600 like in Japan when you have to pay $2k to find the customer.
Let’s have a lower cost sales process. Review 12 companies online, pick top 3, ask them to come out.
I got a variety of explanations for why they weren’t going to do it, most of them along the lines of ‘I’ve been doing this forever - I know what I’m doing,’ but a few disappointingly ‘I don’t know what a manual J is.’ Again, this was AFTER my telling them over the phone that I wouldn’t consider a quote that wasn’t based on the calcs.
I can see it being reasonable to explain during the initial contact that you want the standardized estimate, once that happens it's not really on the customer if the contractor goes out to chase the business even if they know they aren't going to do it.
What if I want more humidity?
(The traditional way with a furnace would be with a bypass humidifier, where ultimately, the energy to vaporize the water comes from whatever the heat source of the furnace is.)
“It’s a feature, not a bug. Just put on a hoodie and get under the blanket!”
Mitsubishi sells heat pumps that produce 14kw of heat output all the way down to 5f at a COP of 2.3.
Resistive heat has a COP of 1, by definition.
Do you know the size of your oil burner? It's likely over 20kw output.
It's not that pumping heat cannot work sufficiently at cold temperatures, it's that you are expecting the electric car rated 100 horsepower to go as fast as the gas car rated at 300 horsepower.
An oil burner sized to the same output as the heat pump also would not keep up.
If you installed two of those Mitsubishi heat pumps (which would require two independent 240v circuits), you would be at 28kw output and would not need resistive heat strips. These units also claim 75% rated capacity at -13f so that would be about 21kw of heat output even when very very cold.
If your resistive heat strips activate at any point other than extreme weather events or emergencies, your "system" is not sized properly. They are a massive waste of power and money.
A big part of the problem is that the contractors who are essentially the point of sale for these systems are just obscenely dumb about them. They will sell you utterly undersized units or sell units that aren't rated for cold, as well as just install things so poorly that they drain condensate into your walls and cause mold issues. They had similar problems with Oil burners, but at least those they tended to upsell bigger systems so their ignorance didn't matter. They seem very bad at doing the planning or design required to actually spec out a system, so you have to be your own engineer.
>and that is what the industry needs to work on.
I don't know how the industry is supposed to force contractors to read their very very clear documentation, or follow the very clear instructions (of boiler manufacturers no less) of "You must measure heat load to accurately size a heat appliance".
I don't think latitude is a factor in how efficient a heat pump you can find, I think the type geography under you feet is (probably where "interior" regions probably have more luck than coastal regions), combined with how well regulated or unregulated your area's aquifer generally is (things like nearby wells and industrial water dumping will effect aquifer levels and temperatures). (Maybe not enough heat pump proponents realize that you only have good, cheap heat pumps if you have a powerful EPA and other Water protection groups fighting the good fight in your region.)
These are entirely disjoint concepts.
40K is also on the low end for geothermal. I'm guessing you were able to trench instead of drill?
If you can afford ground source it's by far the best option in cold climates. Steady ground heat means you get the same efficiency all year round. The install can be eye-watering though.