I decided to pull an extra 240V line to the countertop explicitly for a tea kettle, which I have not purchased yet but seem to be available from Amazon UK for ~2x the price of an ordinary US-market kettle.
The most disappointing thing so far is the short list of kettle options that ship from the UK to the US.
Also not sure if I should get a UK receptacle (this would probably offend the bldg inspector, so I might swap post-inspection), or just rewire the kettle itself with a standard US (240V) plug.
FWIW, the extra wire + breaker cost was about $100. I expect to pay another $30 or so for the receptacle or appliance wire, and a bit over $100 for the kettle (and its replacements every few years). Not the least expensive option, but not too bad.
Whether it's actually safe I though, that I am curious. Obviously the kettle can get the 240V potential it expects, but the neutral is center tapped out of the split phase transformer, right? Not sure how people wire this. (Doesn't the neutral wind up having to be one of the hots instead?)
In the US, it's 240V 60Hz, split-phase with center-tapped neutral, and an independent ground wire.
In the UK, it's 240V 50Hz, single-phase with independent neutral and ground.
Frequency difference should be within design tolerance. and if my EE memory serves, the phase difference should be acceptable -- just measured from a different zero reference point. The neutral from the wall would be unused, and the ground would be wired as usual.
I'll think this through thoroughly though, I was definitely glossing over those details, so thank you!
Both live and neutral wires have to be treated as if they were both live, because 50% of the time they'll be swapped around.
E.g, something like this:
(US proposed) (UK kettle) (UK standard)
(2-phase) ┌─────────────┐ (1-phase)
│ │
L1 120V 0° ────┼─ Hot(240V) ─┼── Hot 240V 1ph
│ │
Neutral ───X │ │
│ │
L2 120V 180° ──┼─ Neutral ───┼── Neutral
│ │
│ │
GND ───────────┼─ GND ───────┼── GND
│ │
└─────────────┘
I think this is right, but I'm not 100%. The kettle should get what it needs, but I'm less certain whether a GFCI or ArcFCI breaker would have opinions that must be accounted for. I'll check with someone more qualified than myself to be sure!