488 points · by lpage · 11mo ago · 210 comments
On the fridge itself: You may find that the contents are insured against power outages.
As an anecdote, my (completely not-special) homeowner's insurance didn't protest at all about writing a check for the contents of my fridge and freezer when I asked about that, after my house was without power for a couple of weeks following the 2008 derecho. This rather small claim didn't affect my rate in any way that I could perceive.
And to digress a bit: I have a chest freezer. These days I fill up the extra space in the freezer with water -- with "single-use" plastic containers (water bottles, milk jugs) that would normally be landfilled or recycled.
This does a couple of things: On normal days, it increases thermal mass of the freezer, and that improves the cycle times for the compressor in ways that tend to make it happier over time. In the abnormal event of a long power outage, it also provides a source of ice that is chilled to 0F/18C that I can relocate into the fridge (or into a cooler, perhaps for transport), to keep cold stuff cold.
It's not a long-term solution, but it'll help ensure that I've got a fairly normal supply of fresh food to eat for a couple of days if the power dips. And it's pretty low-effort on my part. I've probably spent nearly as much effort writing about this system here just now as I have on implementing it.
tl;dr - the fire destroyed over 1,000 homes, two deaths. The local electrical utility, Xcel, was found as a contributing cause from sparking power lines during a strong wind storm. As a result, electrical utilities now cut power to affected areas during strong winds.
The failure of a single such server is far from a disaster.
But the stratum 1 time servers can shrug and route around the damage.
Time services are available from other locations. That's the disaster plan. I'm sure there will be some negative consequences from this downtime, especially if all the Boulder reference time sources lose power, but disaster plans mitigate negative consequences, they can't eliminate them.
Utility power fails, automatic transfer switches fail, backup generators fail, building fires happen, etc. Sometimes the system has to be shut down.
Remember - the Marshall fire started on December 30, 2021 under similar high wind conditions. [2] 1,000 structures destroyed, two deaths.
There's no present need for important hard-to-replace sciencey-dudes to go into the shop (which is probably both cold, and dark, and may have other problems that make it unsafe: it's deliberately closed) to futz around with the the time machines.
We still have other NTP clocks. Spooky-accurate clocks that the public can get to, even, like just up the road at NIST in Fort Collins (where WWVB lives, and which is currently up), and in Maryland.
This is just one set.
And beyond that, we've also got clocks in GPS satellites orbiting, and a whole world of low-stratum NTP servers that distribute that time on the network. (I have one such GPS-backed NTP server on the shelf behind me; there's not much to it.)
And the orbital GPS clocks are controlled by the US Navy, not NIST.
So there's redundancy in distribution, and also control, and some of the clocks aren't even on the Earth.
Some people may be bit by this if their systems rely on only one NTP server, or only on the subset of them that are down.
And if we're following section 3.2 of RFC 8633 and using multiple diverse NTP sources for our important stuff, then this event (while certainly interesting!) is not presently an issue at all.
Fun facts about The clock:
You can't put anything in the room or take anything out. That's how sensitive the clock is.
The room is just filled with asbestos.
The actual port for the actual clock, the little metal thingy that is going buzz, buzz, buzz with voltage every second on the dot? Yeah, that little port isn't actually hooked up to anything, as again, it's so sensitive (impedance matching). So they use the other ports on the card for actual data transfer to the rest of the world. They do the adjustments so it's all fine in the end. But you have to define something as the second, and that little unused port is it.
You can take a few pictures in the cramped little room, but you can't linger, as again, just your extra mass and gravity affects things fairly quickly.
If there are more questions about time and timekeeping in general, go ahead and ask, though I'll probably get back to them a bit later today.
I thought it was US Space Force / Air Force. Was the Navy previously or currently involved?
That's some strong winds! What's causing such strong sustained/gusty winds that long? I'm hearing about this weather phenomenon for the first time.
[1] https://www.eecis.udel.edu/~mills/ntp.html
That's why the most stable ones are insulated and ovenized[1].
So an AC failure which would lead to higher room temperatures would lead to stronger or more frequent correction by the NTP client, as the local oscillator would drift more.
Not sure about the fire case though. I mean the same applies there but I'm not imaginative enough to think of a realistic scenario where NTP would be useful for averting a fire.
[1]: https://blog.bliley.com/anatomy-of-an-ocxo-oven-controlled-c...
Having a parallel low bandwidth, low power, low waste heat network infrastructure for this suddenly seems useful.
WWV still seems to be up, including voice phone access.
NIST Boulder has a recorded phone number for site status, and it says that as of December 20, the site is closed with no access.
NIST's main web site says they put status info on various social media accounts, but there's no announcement about this.
Being unfamiliar with it, it's hard to tell if this is a minor blip that happens all the time, or if it's potentially a major issue that could cause cascading errors equal to the hype of Y2K.
And most enterprises, including banks, use databases.
So by bad luck, you may get a couple of transactions reversed in order of time, such as a $20 debit incorrectly happening before a $10 credit, when your bank balance was only $10 prior to both those transactions. So your balance temporarily goes negative.
Now imagine if all those amounts were ten thousand times higher ...
That purpose equates to over $12 billion in fees for 2024
https://finhealthnetwork.org/research/overdraft-nsf-fees-big...
Asking for a friend.
The main problem will be services that assume at least one of the NIST time servers is up. Somewhere, there's going to be something that won't work right when all the NIST NTP servers are down. But what?
If you have information on what they actually are using internally, please share.
Example: https://www.microchip.com/en-us/products/clock-and-timing/co...
the NIST hydrogen clock is very expensive and sophisticated.
For this though you need to go beyond NTP into PTP which is still usually based on GPS time and atomic clocks
https://static.googleusercontent.com/media/research.google.c...
https://static.googleusercontent.com/media/research.google.c...
The ultimate goal is usually to have a bunch of computers all around the world run synchronised to one clock, within some very small error bound. This enables fancy things like [0].
Usually, this is achieved by having some master clock(s) for each datacenter, which distribute time to other servers using something like NTP or PTP. These clocks, like any other clock, need two things to be useful: an oscillator, to provide ticks, and something by which to set the clock.
In standard off-the-shelf hardware, like the Intel E810 network card, you'll have an OXCO, like [1], with a GPS module. The OXCO provides the ticks, the GPS module provides a timestamp to set the clock with and a pulse for when to set it.
As long as you have GPS reception, even this hardware is extremely accurate. The GPS module provides a new timestamp, potentially accurate to within single-digit nanoseconds ([2] datasheet), every second. These timestamps can be used to adjust the oscillator and/or how its ticks are interpreted, such that you maintain accuracy between the timestamps from GPS.
The problem comes when you lose GPS. Once this happens, you become dependent on the accuracy of the oscillator. An OXCO like [1] can hold to within 1µs accuracy over 4 hours without any corrections but if you need better than that (either more time below 1µs, or more accurate than 1µs over the same time), you need a better oscillator.
The best oscillators are atomic oscillators. [2] for example can maintain better than 200ns accuracy over 24h.
So for a datacenter application, I think the main reason for an atomic clock is simply for retaining extreme accuracy in the event of an outage. For quite reasonable accuracy, a more affordable OXCO works perfectly well.
[0]: https://docs.cloud.google.com/spanner/docs/true-time-externa...
[1]: https://www.microchip.com/en-us/product/OX-221
[2]: https://www.u-blox.com/en/product/zed-f9t-module
[3]: https://www.microchip.com/en-us/products/clock-and-timing/co...
Everyone else is already connecting to load balanced services that rotate through many servers, or have set up their own load balancing / fallbacks. The mistakenly hardcoded configurations should probably be shaken loose anyways.
Says it's still mostly up.
The network will route around the damage with no real effects. Maybe a few microseconds of jitter as you have to ask a more distant server for the time.
The answer is no. Anyone claiming this will have an impact on infrastructure has no evidence backing it up. Table top exercises at best.
Perhaps, "We don't know." will become popular?
https://jila.colorado.edu/news-events/articles/spare-time
Discussed here: https://news.ycombinator.com/item?id=46042946
And how many randomly chosen wristwatches would you need to get anything reasonable?
But yes, good point.
Given two time changes per year I guess something like 1 min per year is acceptable
It's open to the public for visits. They have a small science museum, offices, a library, etc. I highly recommend anyone with interest and opportunity to visit the mesa lab soon. It may not be open much longer. The view alone is worth the trip, and the building is cool too.
THE TIME RIFT OF 2100: How We lost the Future --- and Gained the Past.
https://tech.slashdot.org/comments.pl?sid=7132077&cid=493082...
This is some level of eldritch magic that I am aware of, but not familiar with but am interested in learning.
Probably more interesting is how you get a tier 0 site back in sync - NIST rents out these cyberpunk looking units you can use to get your local frequency standards up to scratch for ~$700/month https://www.nist.gov/programs-projects/frequency-measurement...
Also thank you for that link, this is exactly the kind of esoteric knowledge that I enjoy learning about
Many data centers and telecom hubs use local GPS/GNSS-disciplined oscillators or atomic clocks and wouldn’t be affected.
Most laptops, smartphones, tablets, etc. would be accurate enough for days before drift affected things for the most part.
Kerberos requires clocks to be typically within 5 minutes to prevent replay attacks, so they’d probably be ok.
Sysadmins would need to update hardcoded NTP configurations to point to secondary servers.
If timestamps were REALLY off, TLS certificates might fail, but that’s highly unlikely.
Databases could be corrupted due to failure of transaction ordering.
Financial exchanges are often legally required to use time traceable to a national standard like UTC(NIST). A total failure of the NIST distribution layer could potentially trigger a suspension of electronic trading to maintain audit trail integrity.
Modern power grids use Synchrophasors that require microsecond-level precision for frequency monitoring. Losing the NIST reference would degrade the grid's ability to respond to load fluctuations, increasing the risk of cascading outages.
To quote the ITU: "UTC is based on about 450 atomic clocks, which are maintained in 85 national time laboratories around the world." https://www.itu.int/hub/2023/07/coordinated-universal-time-a...
Beyond this, as other commenters have said, anyone who is really dependent on having exact time (such as telcos, broadcasters, and those running global synchronized databases) should have their own atomic clock fleets. There are thousands and thousands of atomic clocks in these fleets worldwide. Moreover, GPS time, used by many to act as their time reference, is distributed by yet other means.
Nothing bad will happen, except to those who have deliberately made these specific Stratum 0 clocks their only reference time. Anyone who has either left their computer at its factory settings or has set up their NTP configuration in accordance to recommended settings will be unaffected by this.
NIST currently offers this service free of charge. We require written requests to arrive by U.S. mail or fax containing:
Your organization’s name, physical address, fax number (if desired as a reply method).
One or more point-of-contact personnel or system operators authorized to receive key data and other correspondence: names, phone numbers, email addresses. Up to four static IPv4 network addresses under the user’s control which will be allowed to use the unique key. By special arrangement, additional addresses or address ranges may be requested.
Desired hash function (“key type”). NIST currently supports MD5, SHA1, SHA256, and HMAC-SHA256. Please list any limitations your client software places on key values, if known: maximum length, characters used, or whether hexadecimal key representations are required. If you prefer, please share details about your client software or NTP appliance so we can anticipate key format issues. Desired method for NIST’s reply: U.S. mail, fax, or a secure download service operated by Department of Commerce.
NIST will not use email for sending key data.
ps. there actually seems to be improvement over what they had year ago. they added "secure download service". and previously they had message that nobody assigned to actively monitor mailbox so if you didn't get key, please email us so we will check it
While underground distribution systems are less prone to interruption from bad weather it depends on the circuit design. If the underground portion of the circuit is fed from overhead power lines coming from the distribution substation you will still experience interruptions from faults on the overhead. These faults can also occur on overhead transmission circuits (the lines feeding the distribution substations and/or very large industrial customers).
Underground distribution comes at a cost premium compared to overhead distribution. It’s akin to the cost of building a picket fence vs installing a geothermal heating system for your home. This is why new sub divisions will commonly have underground cable installed as the entire neighborhood is being constructed - there’s no need to retrofit underground cable into an existing area and so the costs are lower and borne upfront.
It’s more cost effective for them to turn the power off as a storm rolls through, patrol, make repairs and reenergize then to move everything underground. Lost revenue during that period is a small fraction of the cost of taking an existing grid and rebuilding it underground. This is especially true for transmission circuits that are strung between steel towers over enormous distances.
Some of it is physical infrastructure (transformers, wire, poles), but a lot of it is labor.
Labor is expensive in US. It’s a lot of labor to do, plus they’ll likely need regulatory approval, buying out land, working through easements.
At the same time you have people screaming about how expensive energy is.
Furthermore they have higher priorities, replacing ancient aging infrastructure that’s crumbling and being put on higher load every day.
https://practical.engineering/blog/2021/9/16/repairing-under...
remote refid st t when poll reach delay offset jitter
==============================================================================
+time-e-b.nist.g .NIST. 1 u 372 1024 377 125.260 1.314 0.280 #time-e-b.nist.g .NIST. 1 u 1071 1024 377 125.260 1.314 0.280Maybe their generator failing was DOGE related, but wouldn’t have happened if state level shenanigans were better handled
Don't forget Solar Roof.
Some relevant DOGE’s effects:
-time and frequency division director quit
-NIST emergency management staff at least 50% vacant
-NIST director of safety retired, and NIST safety was already understaffed when compared to DOE labs
-NOAA emergency manager on the same Boulder campus laid off
etc
It’s just a good idea, though, not a greedy one… so it won’t happen.
And far from a disgrace, NTP was a brilliant design for its time, and has proven to be far more future-proof than should have been expected.
Future proof? Are you living in the same future I am where our trades are front run? I notice you didn’t engage with the substance of my attack at all.