Usually you want to keep the heat and put it back into the compression medium during decompression and hope that losses from the heat storage aren't too big, but when you have a cooling use case nearby, you can use that low intensity heat to compensate heat storage losses, or even overcompensate. When you consider how much of the power input of a datacenter is typically used for cooling, compressed gas storage could be useful even if there was zero electric recovery (just time-shifting the power consumption for cooling to a time with better energy availability)
a thermal-energy-storage system cools the CO2 to an ambient temperature
https://energydome.com/co2-battery/ diagram has water as the heat storage. Tanks of water get efficient at energy storage due to square-cube scaling.So far so good, just the old thermodynamics. It gets interesting when you have a cooling use case anyways: then you can skip on some of the decompression recovery and use the "cold" from decompression directly, to cool down something that needs cooling, without going the extra way of converting back to electricity and then sending the electricity recovered into a compressor setup for "creating cold". Bonus points if you also have a use case for the heat you did not use in reconversion to electricity, but chances are between losses during storage and heating some the gas back some amount beyond neutral you won't have much spare heat anyways.