by condiment · 11mo ago · 0 comments
Soda lime, or calcium hydroxide, is the current state of the art. We use that in an anesthesia and in saltwater aquariums and in scuba rebreathers. An idealized system can capture 500 mg per gram, but in practice you only capture around 250mg/g. This outperforms the method in the article but it’s one-shot. There are interesting proposals to use this for direct capture at industrial facilities and to turn the waste material into bricks for building.
The key advantage of this new material appears to be that it can be heated and reused. That would be very valuable in an interior direct air capture use case. Think about filtering the CO2 from an office or a home to get us back to pre-industrial levels indoors.
Noticeable cognitive impairment starts in the 700-1000ppm range, whereas it is very common for homes to reach 2000-3000ppm, especially when in a closed bedroom.
The US navy failed to detect such effects in submarine crew, even at much higher levels like 10,000 ppm.
Another reason to be skeptical is that exhaled breath is 4% CO2 (40,000 ppm!). Therefore a few thousand extra ppm in the inhaled air should not make much of a difference to the homeostasis mechanisms in our bodies.
I’m sure the CO2 was part of it but lack of circulation also means increasing temperature, especially with a bunch of people in a small meeting room. Long meetings themselves are a problem and any excuse to call it early is probably worth it even if it’s not entirely true.
I’d need to look at the study, but I also suspect the submariners would be used to high CO2, and also not experienced enough in doing focused creative or knowledge work for impaired abilities there to be detectable.
Please consider the possibility that you can accurately detect increased CO2 (it increases your breathing rate almost instantly for example) without it causing impairement.
I have one of those, it blows fresh air in through the bedroom and sucks it back out through the kitchen (loft house, this route prevents food smells from wafting into the bedroom). Aside from just feeling fresh all year, this system also prevents mosquitoes from entering in summer while still allowing air circulation, it automatically bypasses the exchanger at night to provide cool air and it has some pollen filters installed which helps with hay fever.
So great economic return and a bunch of upsides, but it does require space for the exchanger and the ducts throughout the house.
All rooms in the house have an intake or exhaust duct depending on requirements.
There is also a small control panel next to the thermostat in the living room that controls the whole system for when, ahem, your number two's are particularly odorous (or you're using the kitchen to cook for 6).
I have not noticed significant cognitive impairment (not saying it did not happen)
[•] <https://en.wikipedia.org/wiki/Heat_recovery_ventilation#Ener...>
I use a Panasonic model — readily available from Big Box Retail (~$700 + $100 in vent/conduit) — which can do 20 - 60 cfm (in my 900 sqft home this can easiliy exchange the entire volume several times per day).
I am somewhat skeptical of this:
https://www.astralcodexten.com/p/eight-hundred-slightly-pois...
Have you been telling representatives? Here's a letter I wrote to mine:
> In this study, a systematic review and meta-analysis of fifteen eligible studies was performed to quantify the effects of short-term CO2 exposure on cognitive task performance.
> The complex task performance declined significantly when exposed to additional CO2 concentrations of 1000–1500 ppm and 1500–3000 ppm
So we're a long way from needing to scrub co2 from the atmosphere to get any work done
I monitor my indoor co2, but don't take any action because it's extremely rare to be above 700 or 800. I can only remember a handful of times its reached 1k ppm. And my house should be prime candidate for co2, it was built during the era of "seal all air gaps" but before ERV or HRVs. I also use pressurized co2 to inject co2 into a planted aquarium. And my dogs are terrified of open windows so they are rarely open.
This change in scientific literature actually causes a ~quadrupling of recommended airflow ratios for tight homes versus ASHRAE's previous guidelines, putting strong emphasis on an ERV. Previously, ventilation needs tended to be dominated by air quality and smell, by humidity buildup, or by theoretical house parties that maxed out the system.
This ventilation adds capital expense, but it's substantially more controllable and significantly cheaper in the long run in colder climates than 'just open a window' or 'just don't build the house so tightly sealed'. Reserve the operable window for the aforementioned house party, which is out of a reasonable design envelope.
My bedroom was quite small at the time, but I measured the same effect of buildup in a larger bedroom, just the Co2 level took a little longer to reach it's peak.
In the small room it took about 45 mins to climb to about 1400 after I closed the door and went to sleep.
I'm currently trying to install some above-door vents to improve circulation but this is a topic most people don't consider at all, even though studies have shown the effects of classrooms having high Co2 concentrations on exam results and cognition.
CO2 rises really fast with people in even a large space.
I wouldn’t put too much effort into vents above a door as we’ve seen that CO2 will leak through doors and even floors/ceilings very quickly.
Edit: missed a letter
This is the meter I am using, costs $39, and is a calibrated instrument with +/- 3% accuracy. I have an academic colleague that uses these same devices for scientific research on plant metabolism, and they are highly accurate and are optionally self calibrating just by opening a window or putting them outdoors.
https://www.co2meter.com/collections/indoor-air-quality/prod...
Sounds seriously unlikely. How would this work in practice, at the level of bodily functions?
Several other posters in here have posted peer reviewed studies replicating these effects, but personally I find individual direct experience with my own body to be massively more generally useful when making health decisions than studies in other people, or some known mechanism.
I have no idea why the journalist that wrote this article choose to highlight the carbon density of the sub-header. It's almost completely irrelevant for carbon capture plants.
Another clear benefit is that it's a liquid.
Today people mostly use the substances that you called non-reversible in research plants (AFAIK, all plants are research right now). They are perfectly reversible, but that uses a lot of energy.
Looks like a perfect match to a solar plant, which provides basically free energy periodically. All you need is a large enough cistern to hold the liquid during night time.
But you don't need to store the capture medium. You use a bit more energy to make they work faster while the Sun is shining, and stop everything when it's gone.
The largest bottleneck is what you do to get rid of the CO2.
The hard part is capture and disposal.
Extending the current exponential for 20 years, we get into the 500ppm region.
I don't think that's enough to need scrubbers.
If your room has 2 times the open air concentration, and you are concerned if it's 2.0 times or 2.2 times, you should already be dealing with the problem.
From https://www.climate.gov/news-features/understanding-climate/..., the pessimistic projections suggest that we may reach our 700 ppm threshold by roughly 2070; 45 years from now. (The graphs are hard to read precisely)
The 300 ppm offset compared to the outside air is naturally just an arbitrary number, everything up to 1000 ppm (meaning everything up to 580 ppm more than atmospheric levels) is considered "acceptable". That means any increase in CO2 concentration will take an indoor environment which used to be considered "acceptable" and make it cross the threshold into "unacceptable". An indoor environment which would've been at 900 ppm around the industrial revolution (280 ppm) would've crossed the threshold when we surpassed 380 ppm (which was in 1965 according to https://www.statista.com/statistics/1091926/atmospheric-conc...).
let's compare the past 20 years. In 2004, the concentration was ~377 ppm. That's 47 ppm lower than what was in 2024. An indoor environment which was "borderline but acceptable" at 955 ppm CO2 in 2004 would've crossed the arbitrary 1000 ppm threshold by now, and therefore would benefit from a CO2 scrubber. The next 20 years will likely have a higher increase than the past 20 years, so there will be a larger range of currently acceptable indoor environments which will cross the 1000 ppm threshold by 2045.
TL;DR: It's complicated, 20 years is arbitrary, but as CO2 concentrations increase, indoor quality gets worse so indoor environments which were already bad will become worse. 45 years is a more realistic estimate for when your typical good indoor environment will become unacceptable, but it's a gradient.
Buildings with higher people/sqft could already take advantage of indoor co2 scrubbers today.
Just extrapolate.
Imagine capturing CO2 to turn it into cement, used for constructions.
Pardon my ignorance, though.
It is a kind of cement that uses CO2 to cure.
https://www.researchgate.net/post/Minimum_necessary_concentr...
It’s an interesting exercise to try to figure out what the ideal co2 level should be. Why are we fixated on preindustrial levels. I’m very open to thinking 600ppm might be more ideal than the current level.
I feel that idea has some support from things like the optimal for many crops/greenhouse plants being 800–1,200 ppm. And that Earth's vegetation has greened since the 1980s due to increased CO2.
Cost will be the biggest question. A reusable scrubber need to be cheap enough that the reduce efficiency is worth it.