by lbotos · 10mo ago · 0 comments
(Like a reef tank sterilizer)
For use cases where the emissions are contained (HVAC, water tanks, etc), I think it's a slam dunk from an electronic antiseptic perspective. UV is somewhat common in water filtration today, but perhaps an improvement is possible if these bulbs last longer than existing UV solutions.
[1] https://levoit.com/collections/humidifiers-diffusers/product...
(I do not recommend the humidifier by the way, simply too much work to keep the water tank and the evaporation panels clean, I recommend an ultrasonic version instead)
https://www.mdpi.com/2076-3417/13/7/4141 https://www.boeing.cn/cti/downloads/Boeing-Compatibility-of-...
Summarized here, along with other materials considerations: https://blueprintbiosecurity.org/u/2025/06/Blueprint-for-Far...
It is complete nonsense to point this at people.
This is a study of the Ushio Care222 unit, but its underlying physics is the same as any other KrCl excimer lamp, so its pretty implausible for other KrCl lamps to exhibit spectral drift when this one doesn't.
The spectrum does change a bit over time--it actually gets less dangerous. But it's a very slight difference.
Ducting it kills most of the effectiveness though--now you have to move air through your ducts in order to treat it, so you only get as much treatment as you move air--usually not very fast or else it would be loud and annoying. You can move it faster, but then you need more UV since the faster-moving air won't be exposed for as long. Honestly, upgrade to a MERV-13 filter before thinking about residential in-duct UV
In-room UV is a different story--since it exposes all room air, pathogens start getting inactivated as soon as they're exhaled. The whole room becomes a disinfection reactor.
If I recall correctly my furnace guy quoted me less than $2k for a whole house system that attaches to the air intake on my furnace.