by aaronbrethorst · 10mo ago · 0 comments
I now have several plants in there that are supposed to be especially good at sucking up CO2, and my sensor reports that the current level is slightly below atmospheric ambient CO2 levels.
I also wrote up a blog post about the structure of the Washington state legislature, which began its sixty day session for 2026 earlier this week. https://www.brethorsting.com/blog/2026/01/how-the-washington...
It's about a company (https://neoplants.com/ ) which genetically enhances plants and soil with a product you can buy to make them much more efficient at filtering the air. It apparently does work rather than being a placebo.
I open the window.
Any chance you can share a picture of the size of your room and amount of plants and type of plants?
I have a co2 device which gets red and this triggers the window opening for me asap
Surprisingly, i couldn't find any calculator or theoretical approach for estimating this (given room of a certain size, how long does gas need to equilibriate with outside atmospheric composition to within some tolerance, through a hole of certain size)
ALPSTUGA
My house stays around 800-1000ppm CO2 all the time The HVAC is poorly designed in my opinion.
Actually, the entire new line of Ikea smart home devices are really fantastic. They're all equipped with Thread radios and use Matter, which means they integrate directly into Apple's Home app without needing a separate hub.
And they're dirt cheap. I haven't been able to find another Thread/Matter button for less than $20, but Ikea's is like $6.
The part from the post that answers your question is this:
The sensing platform used is a Sensirion SEN63C, which uses a STCC4 for CO₂ measurements. Unfortunately, this is not an NDIR sensor. Instead it uses less accurate thermal conductivity sensing. This allows building smaller/cheaper sensors, but it depends on the input of the temperature/humidity sensor, because e.g. humidity influences measurements. Also, the sensor relies on the air mixture being 78% N₂, 21% O₂, 0.93% Ar, 400 ppm CO₂ and will stop giving accurate readings when this composition changes (modulo CO₂). The operating conditions are also more limited than most other CO₂ sensors (10–40 °C, 20–80% RH).
From what I could gather and what is also mentioned in the conclusion is that the sensor is fine to get a general feeling of the CO2 trends, but that you're better off getting a better sensor if you care about exact values.
I have a Netatmo home device that measures PPM and have been observing the trend lines throughout the day. At some points my flat gets up to about 1400, which the device says is bad, and sometimes it goes down as low as 500. I've noticed a pattern but can't quite connect that pattern to my activity or the surroundings. It starts going up around 4pm, which could be homewards-bound vehicles, but it seems to trend even on weekends when there is lower traffic. Maybe I start breathing differently at these times. I'm quite interested in getting to the bottom of it. Unfortunately I'm west facing so plant use is quite limited.
What is the atmospheric ambient CO2 level? Is that variable based on location?
I've learnt a few things:
- I had my sensor on my work desk which meant the CO2 pooled, and was increased dramatically by my breathing almost directly onto it. Moved the sensor at least 1.5m
- I had the sensor quite low down, where CO2 pools (being heavier), so moved the sensor to eye level
- CO2 seemed to increase when cooking (same room), so while cooking I open the windows and let the warmth flow out of the building
Also important is using a direct CO2 sensor (NDIR or photo acoustic) and not eco2 which can give false positives from other things in the air.
It's been a long time since University for me but the standard measurement location is the Mauna (sp?) Loa Observatory in Hawaii, if I recall correctly due to it being the longest-running continuous measurement site.
it's unlikely that you can add enough to make a big difference. plants are nice, but people often ascribe far more to them than is really happening - have you improved the ventilation too?
Plants would have to fix 100 watts worth of carbohydrates to simply maintain balance. Only a few plants can achieve 5% efficiency, so minimum you’d need 2 kW of light being absorbed by your plants.
That’s a weed grow room, not an office!
I often feel tired at the end of the day and I'd attributed it to just working quite long hours, but maybe it is related to this.