There's a NYT article on the challenges about this from a few years ago: So You Want to Turn an Office Building Into a Home? -- Here’s How to Solve a 25-Story Rubik’s Cube https://www.nytimes.com/interactive/2023/03/11/upshot/office...
You can think of class c office space, broadly speaking, as oil wells that have very little life left, and get bought up by folks who intend to extract the cashflow until they dump the externality on the public government and taxpayers (like abandoned shopping malls).
A recent example in St Louis is the AT&T office tower [1] [2].
[1] One of St. Louis’ tallest office towers, empty for years, sells for less than 2% of its peak price - https://www.costar.com/article/642008108/one-of-st-louis-tal... - April 10th, 2024 ("Goldman Group buys 44-story former AT&T office tower for $3.6 Million")
[2] St. Louis office vacancy hits all-time high [21.2%] as major companies downsize their footprints - https://www.bizjournals.com/stlouis/news/2026/01/15/office-v... - January 16th, 2026
(conversions when the economics pencil out, haircuts for investors when they don't and more investment is needed to wholesale replace a structure)
US office vacancy rates chart supposedly pulled from Moody's: https://old.reddit.com/r/charts/comments/1p8mhmq/us_office_v...
There should probably building code changes to ban the latter type of office building, and keep the space more flexible and convertible to residential. A big plus is the resulting office space would probably be nicer to workers.
https://www.boston.gov/news/officials-celebrate-first-100-un...
I'm not entirely sure how that math works out, or why, because one would think it couldn't be that complicated. Maybe someone here knows more about this.
There's also a lot of work that probably needs to go in to the ventilation and fire code changes. An office building isn't designed for people having ovens and stoves. It also often just assumes its OK to have less isolation between units for the ventilation, or previously entire floors were considered to be one space ventilation-wise but now you might be trying to split it into 2-3 units that require separation. This separation can also complicate things like AC and heat.
The ventilation issue comes up a good bit with a lot of these poorly done conversions. You end up with units that just don't get nearly enough airflow, and all the windows are sealed so its not like one can just open the window to get more air.
History favors the bold, and code inspectors blabbering about "written in blood" don't see all the homeless people they kill via reduced access to housing.
I've seen plenty of artist collectives that manage it; on paper they are office/industrial but actually everyone lives there. Every once in awhile one burns down but the mortality rate isn't as high as living on the streets which is ultimately what happens to those on the bottom of the socio-economic pyramid when the ones higher up push the ones under them down a rung to snag housing.
You also then had everything pretty much isolated to two rooms for an entire floor meanwhile now every unit is going to have a separate kitchen, a bathroom (or two, or three), a laundry room, etc.
And you're going to need a good bit of engineering studies done before you start cutting that many holes in the floor.
I'm sure many many people have thought of all sort of solutions as the value for finding some sort of solution is extremely high.
A 20,000 sq ft office tower floor will usually have a single set of restrooms and a couple of kitchen sinks, maybe a dishwasher, plus a couple 6-gallon or instahot water heaters. If you subdivide that floor into a dozen units, that’s 12 showers, 12 washers, 12 dishwashers, 12 toilets, 24 sinks, and 12 water heaters.
The riser and drain pipes aren’t big enough to handle residential needs.
Yep, and that's fine. It's literally a tangible instance of 'creative destruction'. I see people arguing that oh, we have to RTO to save the current model and it seems so backwards to me.
When it is suggested today modern planners and developers say it can't be done. What changed?
Commercial office buildings are optimized for seating space, so you get a lot more interior walls already built and often shorter ceilings then industrial spaces. That's a lot more renovation to add in all the necessary plumbing for showers and toilets and often laundry in every unit.
New building codes mean that everything has to be done right to today's standards, not yesteryear's, so it becomes cheaper to demolish and rebuild than retrofit, especially if the building has a lot of interior space that doesn't have access to exterior walls for mandated windows.