by jws · 14y ago · 0 comments
I think I might try a no-moving-parts solution and attach an electric heating element to my bleed valve. By heating it just before the steam cycle starts you could prevent steam from entering your radiator, then after a suitable interval, stop heating it, let the air out, and begin your personal, abbreviated cycle.
You might also have success with partial air entrapment in the radiator by heating a little early and keeping the bleed valve closed for the rest of the heat cycle, thereby reducing the available power from the radiator but spread over the entire heating cycle.
In any event, you will want to let the air bleed open after each heat cycle to let your water go.
Oh, and incidentally if you don't have thermistors laying about: http://www.maximintegrated.com/datasheet/index.mvp/id/2815 there is Arduino code. One pin, two wires, one resistor, a bunch of probes, all calibrated and 0.5°C accuracy from -55°C to 125°C. A couple bucks each, you mostly save that in ancillary component costs.
EOM
[1] http://en.wikipedia.org/wiki/Hydronics#Single-pipe_steam
EDIT - could you elaborate on how heating the bleed valve is a good way of controlling it? Isn't it moisture based? --Andrew (Terg.is)
at rest: radiator full of air, valve open
steam begins flowing: steam is displacing air from radiator, bleed valve begins heating up
bleed valve closes: radiator is now full of steam, some of which condenses and ideally runs back down pipe, if your building hasn't shifted too much over the years. any condensed steam is replaced with new steam from pipe
boiler stops: steam is no longer coming up the pipe. As the steam in the radiator condenses we suck air back in through the bleed valve. radiator is cooling.
bleed valve opens: at some point the radiator cools enough that the bleed valve opens. We are now ready to begin the cycle again.
Additionally, I think there is a time delay component in the bleed valve to let it get the air good and purged before it closes.
The valves close when steam reaches them, due to a small amount of alcohol in them turning into vapor and exerting mechanical force to close the valve.