So I'm looking at a backup gas boiler to take load of the heatpump/ground loop (house has radiant heat).
And they are not quiet. 5-Ton water to water compressors are not quiet.
And the control system (HDX) and amount of expertise required to keep the thing running is a major barrier to getting low cost maintenance.
Maybe a 2026-designed system will work better and actually live up to the hype you talk about, but there are decades of poorly designed and discarded ground loop heat pumps that have "poisoned the well" if you will.
Other type is permanent change that persists year over year. Haven't lived here long enough to measure this. But if you pull more heat from the ground in the winter than you put back into it into summer (we use a water to air compressor for AC in summer), then yes, it can happen and does happen. Don't know if we are in this bucket yet.
Sorry to hear this, it seems like a great system to me but you have to have the capacity right. I'm planning on getting one in the next year but the drilling will be more than we need and we opt for no glycol (yet) as that also gives us headroom
Currently system is running 20% methanol to combat the 29degF EWT (entering water temp) in deep winter. House is in Zone 6a.
One thing I learned in researching all of this is that use of ground source over many years can move the bulk ground temp permanently. (House also has water-to-air water furnace for AC). If heat pulled from ground in winter is not sufficiently replaced by heat added during summer, can move bulk ground temp over time. (If densely packed residential ground loops ever became a thing, I think this is a real risk.). But I am not sure if we have this issue at our place, still in first year, not enough data points.