by chimpontherun · 6mo ago · 0 comments
So, I replaced all my UPSes with LiFePO4 batteries supplied by Victron AC->12V chargers. Routed the battery contacts directly to all devices that consume 12V (WiFi AP, network hubs, SLA 3d printers). Used 12V -> 5V adapters to supply 5V / USB2 devices (R-Pi servers). For 19V, Drok DC-DC boost converters work great.
Result: threw away 3 UPSes (different APC models). Overall power consumption with AC present dropped by about 40%. Time on batteries (same Wh battery capacity) increased by a factor of about 20 (yes, 20 times: that's not a typo). Evidently, AC waveform generation is extremely power-hungry
I've tested a dozen models from APC. The inverter used in those devices uses roughly 15-20W with no load. Then for any load they have about 85% efficiency. Then you have further losses into any PSU connected there because they tolerate square waves but aren't optimized for it. So yes, in the end, less than 40% of the battery capacity in cheaper UPSes is actually usable.
The reason you're seeing 20x is because obviously you've also greatly increased your battery capacity (typical under-the-desk APC units have 70-150Wh capacity, less than half of which is usable as explained above).
> Overall power consumption with AC present dropped by about 40%.
I'm finding that part harder to understand. The UPS consumes almost nothing when AC is on, so that can't be that. You've replaced multiple PSUs by more efficient, bigger ones, sure that can explain part of your improvement. But 40% drop is wild!
Back in the 1990s, one could buy a "double conversion" UPS that converted AC to DC then back to AC, at all times. This was, supposedly, the best type of UPS (in my experience they were also the least reliable)
They are "best" in the sense that your output is completely decoupled from your input so you got the most protection from any electrical noise. The trade-off is lower efficiency (AC-DC-AC roundtrip) and more battery wear (it's constantly 'in use').
Any >10kVA UPS is probably double-conversion/online.
These are also the only variants which will protect you against things like a phase ending up on neutral in a 3 phase power system. I've seen this happen twice. Fried a lot of equipment.
You can put them on street power, you can throw them over to the diesel genny, back onto a secondary genny, back onto street power, and the output won't even ripple.
It's not a good option for home use because it's always sending power through an inefficient path. The devices we use have power supplies that can handle transients and fluctuations.
Then theres trivialities like LFP's voltage being higher so there's less resistive losses, etc
Yes, it's quite ugly. Open up one of these things and you'll find a big block of four transistors (if not more due to doubling up) on a big heatsink. That's the inverter drive bridge, and it's probably the single largest source of heat in the whole thing. It's not hard to find.
A huge decision on that was that they publish a fat PDF with the full spec of the serial data they emit and can be programmed with, and a service sheet to allow a suitably skilled engineer to fully bench test them if there are any perceived problems.
They're not cheap, but my late father always used to say he didn't have enough money to buy cheap tools.
Edit: handy hint too - many cheap crappy power bricks will work down to 90V and will work just as well off DC as well as AC because the very first thing they do is rectify and smooth the incoming supply.
I do not recommend having 90V DC kicking around unless everyone involved knows what they're getting into.
I even made an Arduino-based module that provides an SNMP UPS interface for my Synology NAS. It works surprisingly well and has almost 12 hours of autonomy compared to barely 2 hours for the much heavier lead-acid battery.
One trick that I'm kinda proud of: I powered my server directly from the 96V DC. And I periodically switch the current direction using a DPDT relay to avoid wearing out one side of the rectifier inside the PSU.
If you are seriously worried about this then the whole thing is trash. Either the design is marginal or it is not. You cannot possibly switch a relay fast enough to make a difference here (and have the relay survive).
If you are truly close to the design failure point of the rectifier, it's not safe to run at all. (You are almost certainly not.)
If you are worried about the fact that you're only using one element of a multi-element package, again, it's a nonissue. We do this all the time. It's often cheaper to add a second bridge rectifier to get a single diode than it is to add another BOM line item for the "proper" part. As long as that diode isn't operating near absolute maximum ratings (it probably isn't), it doesn't matter that there are or aren't three more in the box.
If you're specifically worried about wear, then you could switch once a month and it would be enough.
(At least not on timescales relevant to individual humans.)
So hearing that makes me get suspicious that something else is going on.
The only thing to be careful with is connecting different voltages to different connectors, but it's at least possible with the APP connectors to "Build your own" with different color housings and different ways of combining the housings.
So maybe 13.8v is red/black and something that's 5V is black/white, etc.
The Drok DC-DC did not work for my minipc that needed 19V/130W supply (would cut off with heavy draw), but the JacobsParts LTC3780 130W has been running my minipc's for almost a year now, gaming minipc, server minipc and networking
before that the solar panels barely charged the solix unit, but now my batteries fully charge and I still sometimes have left over solar I feed into the solix
Evidence is the heat from that conversion