by noncoml · 4mo ago · 0 comments
I had a Google interview collapse because the last interviewer was a Principle Engineer who just couldn’t accept that a switch will ever forward a frame before reading in full and checking the FCS.
I was too much of an idiot to go along with it and instead ended up having an argument with him.
As far as advanced features go, even adding and removing VLAN tags is a headache in a cut-through switch.
Not really; it just needs to inject the tag right after the source address, or not pass it through at all; and of course recompute throughout and replace the FCS at the end. Other more advanced packet editing can be done in a streaming fashion too, with the latency only limited by the length of any "forward references" needed.
With a traditional cut-through switch the entire packet is passed as-is, so you're not modifying a corrupt package. You don't drop it, but the corruption is trivially detectable on the other side. If you naively recompute the FCS on transmit you essentially mark a corrupted package as valid, so you have to compute the FCS on transmit and receive, and intentionally send out the wrong FCS on transmit if you determine the receive FCS is invalid.
Yes, exactly; but that isn't particularly difficult either, compared to all the other packet-editing capabilities that switch ASICs have.
That said, there are lazy hardware designers that just slap on a block to recompute the CRC and replace the old one with the new. An experience I had years ago at Red Hat taught me that the hard way as a shiny new Cisco ethernet switch IT deployed ended up costing us weeks of frustration and delayed a release when it caused bit flips in NFS packets during stress testing. The switch was so awesomely advanced that it recomputed the CRC on the bit flipped packets causing kernel builds to fail. <sigh>
Most data-center networks are involve aggregation/spine/core switches at higher speed than TOR/leaf switches - so the packet has to be buffered.
Most every workload is going to involve port collisions (2 packets at the same time needing the same output port) - again a full buffering required (or drops and throughput reduction).
Bigger networks start using vlans, mpls, ip routing at switches, and vxlan - requiring more lookups per-packet, larger "minimum chunks of packet seen before port is determined" sizes, etc reducing the value of cut-through.
And so on.
But i also struggle to find a scenario where a principle engineer at google is refusing to accept that cut-through switches exist, but rather, was refusing to accept that the scenario they're talking through with you would ever involve an effectively deployed cut-through switch (since that's basically never).
When it works, it reduces latency and reduces buffer memory usage a smidge. This ASIC switch can't afford to buffer any packets, so cut through is the only option... AFAIK, most ethernet switches have at least some buffer memory...
> Most data-center networks are involve aggregation/spine/core switches at higher speed than TOR/leaf switches - so the packet has to be buffered.
If you have traffic flowing within a rack, you can cut through for that where the machines attach to the TOR switch at the same speed.
If you have traffic between racks, and it goes through a spine, it likely needs to buffer at the TORs, but it could cut through at the spine.
> Most every workload is going to involve port collisions (2 packets at the same time needing the same output port) - again a full buffering required (or drops and throughput reduction).
Depends on the workload and redundancy requirements. If you want to have dual link aggregation and no loss of throughput with a single lost link, you'll upgrade line speed when link utilization is at 50%, so maybe 50% of packets could be cut through (depending on burstiness). If latency is a key driver, you may have line speed much higher than throughput and have very little utilization.
"Defines a class of service for time-critical frames that requests the transmitter in a bridged Local Area Network to suspend the transmission of a non-time-critical frame, and allow for one or more time-critical frames to be transmitted. When the time-critical frames have been transmitted, the transmission of the preempted frame is resumed. A non-time-critical frame could be preempted multiple times."
Nope, the argument was exactly if a cut-through switch exists or ever existed
Edit: Actually the conversation came back to me:
He asked me about the frame format. Once I drew that on the board, he asked why is the DST before the SRC. My answer was in order for the switch to start doing the lookups ASAP and that's when I mentioned that a cut-through switch can switch the packet before it even finishes receiving it.
After that we spend the rest of the interview time arguing if cut-through switches actually exist or not. Both he and I having too big of an ego to let it go..
Then I was disappointed to enter the real world of networking and learn that it wasn’t actually used as often as I had been led to believe due to conflicting with higher priority features.
So the interview may have been a conflict between textbook learning and the Google engineer’s practical experience. It’s tough to encounter that conflict in interviews because you get two people talking past each other.