What's made this situation worse is that it seems that worry over plasticizers and health etc. has lead to a reduction in the amount being used in cables. I have some power extenstion cables whose jackets have gone so hard that I can no longer coil them effectively — even though I take care the coiled cable still ends up a tangled mess.
Even if silicone jacketing is more expensive it's so good I'd pay extra. Trouble is it's not normally available on products found at the local hardware shop.
Silicone is more flexible and high-temperature resistant, but it does have a major downside of being very easy to cut and strip. That's not great either, especially for power applications where short circuits are a concern.
Silicone also kinda sucks for crimping. Most crimps have one set of tabs which grab the conductor (which is fine) and then another set which grab the insulation, but in the case of silicone the insulation set tend to just slice the insulation and don't mechanically grab it.
AFAIK there's nothing about the SOOW spec that requires EPDM.
PVC, XLPE, and rubber insulation is more durable than silicone. THHN uses PVC, XHHW uses XLPE, SOOW cord uses EPDM rubber.