I want to do this but I'm worried about stressing the compressor with extra start/stop cycles would shorten its lifespan. Maybe they are programmed to overshoot/undershoot the set temp to prolong lifespan?
Disclaimer: I know next to nothing about how ACs work beyond the very basics.
Short cycling would be bad in the sense that the motor frequently turns on. The maximum current is during motor start and the maximum motor coil cooling is when the fan is running at high speed steadily. So if it starts a lot and doesn't run much at high speed you might tend to overheat, sure. That would definitely drastically reduce the motor lifespan.
If you are still starting periodically and running for awhile, you can see where this goes.
I think it's not overshoot/undershoot that is happening so much as delayed kick on.
That said, it's still a mechanical device that can experience stresses caused by cycles. Refrigerant systems also deal with gas/liquid phase changes and high pressures, so most units I've worked with do have a compressor lockout timer that allows a few minutes for temps/pressures to stabilize before kicking the compressor back on.