Not sure how they "feel" the interactions without disturbing them but that's why they are the physicists.
They can't. I don't know if there are quantum complications at that scale that change this picture, but my basic idea from classical physics is that Newton's Third Law says the probe can't have a force exerted on it by the sample (action) without also simultaneously itself exerting a force on the sample (reaction).
> The single-atom moving finger of the nc-AFM
The mass of the detector particle being deflected by the fields is small compared to the mass of the molecule being measured. So a force large enough to move the probe by a lot might still be small enough to only move the sample by a little.
The bottom line is, you can't measure a sample without disturbing it, but as the ratio of probe mass to sample mass shrinks, the level of that disturbance also shrinks. In this case they're using a single atom probe to measure a large organic molecule, apparently the ratio is small enough.
> Resulting movements of the stylus are detected by a laser beam
I guess in order to engineer a system this small, you need a probe to measure the probe. Again I'm guessing the momentum of the photons from the laser that are used to measure the probe atom is small enough not to appreciably deflect the probe.
Obviously there are additional complications at such small scales, and it depends on what you're detecting (measuring / passing through magnetic fields does affect the source since it changes the field), and it depends on what you define as "change" and which quantum mechanics interpretation you subscribe to. I'm just pointing out that the thing being measured doesn't have to be the thing you're investigating, so that law in particular doesn't really imply anything.
Well, that goes without saying. The question is if that "force" used to measure had any, well, measurable impact.
The problem with your explanation is that the probe is much much bigger than 1 atom. It's a whole macroscopic tip, with a mass of a few grams. The tip of the tip use a single CO molecule, so the prove ends in a single atom, but the atom is attached to a big structure. If the tip were thicker, they would measure an average of the surface under the tip, with a very sharp tip they measure a small area.
The molecules are attached to a silver surface, so they are relatively fixed. The O atom in the CO molecule in the tip is approached to measure the force at each point of the surface. I couldn't find the exact distance but Wikipedia says that in similar experiments the distance is between 10A and 100A. For comparison, a bound between two Carbons in a molecule is approximately 1.5A. So the CO molecule is far away and the force is very small (in the absolute and the relative sense), and the system must use an incredible amount of amplification.
But the force in the sample molecule is also relatively small, so it isn't disturbed too much, and the data that you get are very similar to the data of the unperturbed molecule.
I suppose that it's possible to tweak the setting to decrease the distance so the interaction between the molecule in the tip and the sample molecule is smaller. I suppose that it's possible to use this to make some reactions happen, but I don't remember an experiment with this phenomenon. Anyway a usual problem is to crash the tip against the surface. It's bad for the tip, you need to pick another CO molecule and if it hit the sample molecule it could be interesting. With a similar microscope that use the tunnel effect it's possible to move atoms from one place to another, so it's possible to do things on the surface using the correct settings. You can even do a movie! https://news.ycombinator.com/item?id=5637150
I guess I didn't clearly state an additional assumption of my explanation. I assumed the oxygen atom has an electric charge, the rest of the probe structure is electrically neutral, and the electrostatic attraction/repulsion of charges is the mechanism by which the oxygen atom on the probe reacts to the sample [1].
So while the rest of the probe structure does exist, it's effectively [2] electrically neutral.
[1] I think we can agree that the gravitational attraction of the probe and sample to each other is way too small to matter.
[2] I think the large probe structure is close enough to neutral and/or far enough away from the sample to have an effect which is smaller than the effect of the oxygen atom. The structure may contribute some nontrivial amount of noise due to being neither exactly neutral nor infinitely far away, but not enough to totally drown out the signal from the oxygen atom.
Best part about that line of reasoning is that it leads directly to the Heisenberg uncertainty principle which is definitely in play here. The act of them measuring the position of each of the atoms means that they can't know that the atoms aren't moving because of the force they exerted. On such small molecules they can likely be reasonably certain they haven't introduced any errors, but for a much larger sample they'll start to have issues where the act of measuring is going to change the outcome.
What I'm waiting for is when someone figures out how to make diffraction gratings for things in the 5nm area so that you can actually image this stuff with photons rather than with an AFM, that should let them handle larger sheets of graphene, and possibly even look at doped graphene with semiconductor properties to get a really awesome understanding of how and why it works (or doesn't).
Heisenberg uncertainty is much stronger than not being able to observe a system without disturbing it. It's more like, at a physical level, making the probability distribution of a position tight makes the distribution of momentum wide.
[1] http://en.wikipedia.org/wiki/Observer_effect_(physics) [2] http://en.wikipedia.org/wiki/Heisenberg_uncertainty
the main difference is that the diagram is 2D, and molecules are usualy 3D.
In the two variants on the right, their edges seem to be curling upward making a bowl shape. Their edges are also brighter, which perhaps means they are closer to the probe than parts that are farther away. Additionally, the hexagons are also not all the same shape. I assume that's due to the curling.
I would be interested to know if my interpretation of the image is correct, or if the molecule is really flat and what I'm seeing is an artifact.
http://www.sciencemag.org/content/early/2013/05/29/science.1...