by GuiA · 12y ago · 0 comments
> "The kettle had caused the trip. It was no longer safe to use the kettle"
> You know enough to start designing a temp. controlled kettle, and yet you overlooked the simple (and most likely) possibility that the kettle was on the same circuit with another high draw appliance (hair dryer, electric heater, etc.) and the combination of the two resulted in the trip from overload. And that there was nothing in fact wrong with the kettle at all.
We sometimes forget that our hacker minds can be a weakness :)
A kettle might cause a branch circuit to trip - but the whole house??? If that happens you have bigger problems than a kettle.
(Plus in the UK plugs have built in fuses should trip first. So it's pretty doubtful it was the kettle.)
http://www.ctm.co.uk/gallery/Electric/Electric_photo_gallery...
RCDs detect the slightest earth leak, so they are far more likely to trip than the MCB or the fuse on the plug, which only detect a sustained over-current.
No it wouldn't.
You could stick the bare wires of a branch circuit in water and it wouldn't trip the main breaker.
The main breaker will trip if there is a short inside the panel (which is all but impossible unless you are working on it live - which is sometimes done). Or if you used so much electricity you simply overloaded it, but if you did that you have the wrong panel for your house (or you are running some crazy equipment - arc furnace, maybe).
Generally the wiring goes: mains input -> 1 or more RCDs -> several circuit breakers -> several outlets -> fuse in plug -> appliance.
So a grounding fault can take out many circuits, and many-lots of sockets.
Wrong is relative: here in Portugal we pay a fixed monthly fee that is proportional to the maximum load. Having the "right" panel may cost you more even if you use less electricity, so many people choose to carefully manage their loads instead.
If the kettle still works, then problem solved.
If the ($10) kettle is broken, then I'm going to say that it's entirely possible to consider that quality of components, design, and build may account for the difference between a $10 and a $40 kettle.
I often end up spending more on something if I have reasonable evidence it will last longer and/or perform better. And I don't write long articles about how I resent spending the "extra" money.
It would lead to much fun as we reset the RCD and then tried each appliance to figure out which one was faulty.