by itchyouch · 12y ago · 0 comments
Well if it is measured at the 1-second or 1-millisecond level, yes the exchanges are in compliance. At the 100-microsecond, 10-microsecond and nanosecond level, perhaps the exchange is in compliance at the 50th percentile.
It will be interesting to see if the pressure on the exchanges changes course as they empathize with the same type of dissemination problem.
I'm hopeful that, in time, this will be fixed. Not so much because I believe the latency induced by the flawed SIP architecture is material to SIP subscribers, but instead for 2 reasons:
1. The very same architecture that adds latency makes the SIP a SPOF in our market system and as the NASDAQ Tape C outage showed, it can really suck when the SIP doesn't work;
2. The PERCEPTION of unfairness is much more harmful than any actual harm done due to the SIP/direct latency delta. Fixing the SIP can directly correct the source of the perception of unfairness and bring some credibility to the market place and its governance.
http://online.wsj.com/articles/SB100008723963904435249045776...
Those who truly care about latency will be reading the direct marketdata feeds anyway.
The problem I was highlighting is what definition of "same" should the SEC or the exchanges be held to? When measuring 2 packets with the same information egressing an exchange, what delta is appropriate to be considered the "same" time? Should the delta be within 1 microsecond? 10 microseconds? 1 millisecond? If the acceptable delta is say 10 microseconds, what's the acceptable percentile that the prop data was 10mic faster than the SIP data, or the SIP data was 10 mic faster than the prop data? Or is the exchange in compliance as long as the delta's at the 99th percentile don't exceed 10 microseconds?
Nanoseconds count due to efforts like equidistant cabling that the exchanges employ.
For a web property such as the SEC's, should the push service only push out when the webpage is updated? What is the webpages are behind a load balancer and multiple webservers will synchronize within several milliseconds? web requests querying a webserver that is slightly behind in synchronization could be several hundred milliseconds behind, while the push message has already been out for several seconds.
The article is slicing hairs over seconds, which in the web world isn't a big deal to human consumers. But where machines are consuming, even 1 millisecond is an eternity.
In that regime, measuring "same" becomes simple. Measure at the source the venue specific SIP feed (which contains the venue's view of NBBO) and the depth of book feed delta. Over the course of a day, that delta should effectively be 0.
You're absolutely right about the SEC website issue. It's silly to get upset about this since the "web" aspect of the distribution has so many layers.
http://www.utpplan.com/DOC/Q2%20US%20Consolidated%20Tape%20D...
http://www.utpplan.com/DOC/Q1%202014%20U.S.%20Consolidated%2...
Tape C average SIP latency from Q1 2014 to Q2 2014 went from ~1ms to 40-50 microseconds. That's about 20x faster. 40-50 microsecond average is about the technological limit for what these systems can do unless one resorts to FPGAs. Even then, the improvements to be gained is to take a 40-50 microsecond system and make it into a 5-10 microsecond system.
The best network switches today with cut-through propagation have port to port latencies of around 200ns. These things are pretty much approaching the speed of light.
The perception of fairness as it relates to the SIP will always be an issue (even if it isn't a practical issue) as long as there are "two highways" if you will for market data. There is no reason it needs to be this way. Decomposing the SIP solves all issues and embraces the facts that already exists today: the SIP is a leaky lock on a distributed market that can by passed with ISOs and that there is no such thing as the NBBO because NBBO is entirely relative to point of observation.
Doing so, however, would require the venues to give up a major selling point for their lucrative direct data feeds. Not likely to happen.
And once you hit the <1 millisecond level, it's hard to even get reliable measurements, which makes compliance for "same time delivery" really really freaking hard.
Keep in mind, when you're talking about the nanosecond level, you're at the point where the length of cabling between the systems matters.
Sure, there's a lot of new tech coming out, especially with using GPS to synchronize clocks, but it's still a major issue.