by msandford · 11y ago · 0 comments
...said Ellen Hayes, a PG&E spokeswoman. “Having a solar panel that isn’t connected to the grid is like having a computer that’s not connected to the Internet.”
Patently false. It's a great way for them to rationalize their continued existence. But as rooftop solar takes off and the "smart grid" fails to materialize I suspect that you're going to start to see federated neighborhood grids running at 48VDC.
Anything less than 50V isn't regulated by the NEC which is why you're supposed to hire an electrician for new or major upgrades to your house wiring but nobody cares if you put in low voltage pathway lighting, doorbells, networking, etc.
That means that although you'll have to buy thick copper wires, people can wire themselves up with their neighbors LEGALLY to share power. That's a big deal. It doesn't take all that many people to be connected to substantially smooth out fluctuations. Most A/C doesn't run all the time, it's only supposed to be about 15 minutes out of every hour. So if I and four neighbors team up then we might need 5kW of solar panels between us instead of 5kW each. At least if it's somewhere sort-of temperate where A/C isn't crucial at night.
The power electronics to make this happen are getting cheaper by the day. Sure it means having to talk to your neighbors and some retrofitting, but that's doable. And with a lot of new equipment having VFDs in them from the factory (refrigerators, mini splits, even a lot of A/C compressors) it means that the cost of converting them drops even more.
Smart water heaters could also smooth out some excess supply. The water heater would mix cold water with its' stored hot water in different ratios (depending on how much excess electricity there was and therefore how hot the water is) to provide a constant temperature output.
The extremely large capacities possible from vanadium redox batteries make them well suited to use in large power storage applications such as helping to average out the production of highly variable generation sources such as wind or solar power, helping generators cope with large surges in demand or leveling out supply/demand at a transmission constrained region.
Upgrading to city-scale means that the individual consumer will be less likely to have to wait for their electricity ration.
The hard part is defining the system for such a "smart grid" to safely coordinate activities while being resistant to tampering, spoofing, or other cyber warfare.
As an example, a smart grid will be able to deal with "time of use" charging, meaning that solar electricity produced during the early morning or late afternoon will be far more expensive than what is produced at noon/zenith. A malicious party might attempt to fake the production of electricity in order to get third parties to "buy" electricity that was never produced. This will lead to brown-outs as there is more demand than generation, while the fraudster "selling" the fake electricity will be quite hard to catch.
Even worse, a fraudulent network company might decide to under-meter your production so they can make a profit from the extra electricity that you produced that they aren't paying you for.
Starting at the "four neighbours build a DC network" level, how do you determine which of your three neighbours is not producing electricity when they claim they are?
I can think of a bunch of ways to handle the honesty problem. If it was just say 6 houses I'd probably wire the whole thing as a star and put a current measurement device on each of the 6 hot wires that all connect at the central location. It's then very easy to tell where power is coming from and going to.
Each person could also install their own current measurement device where the power attaches to their in-house system and monitor internally and compare so that way if the central unit gets compromised any individual knows it and can stop participating until it's fixed.
Or maybe not the street address ... use the lat-lon, or phone #, etc.
I've done a fair amount of line-voltage house/business wiring myself, and I've never taken any electrician's tests, but then again this hasn't been in highly unionized/severe inspection locations.
I can't believe someone actually stuck essentially needles connected to a power source into his blood. What. The. Fuck.
That means your round-trip run is only 100 feet so you can look at this chart (http://en.wikipedia.org/wiki/American_wire_gauge#Tables_of_A...) and divide the Ohm/kfoot by 10. If you used 4 gauge that would be 0.24 ohm/kfoot or 24 milliohms per 100 feet. 24 milliohms on 100 amps is 2.4 volts of droop or a 5% loss. Not awesome, but as an engineer, acceptable.
The 4 gauge is available in quantity for less than $1/ft. 1 gauge is available for about $2/ft neither of those prices are all that daunting.
If you lived on the ideal setup where you have neighbors on either side and off the backyard you could wire 6 houses together for less than $1000. Divided 6 ways that's $160 as a one-time cost to be able to be a lot less careful about your power usage. Hell everyone could net-meter with each other and settle up occasionally if someone's consumption got severely out of balance.
The thing that I really like about this (and which perhaps makes me overly optimistic) is that it would spur a lot of neighborhood engagement and re-forming of communities in the suburbs, which is somewhere that's severely lacking in a lot of places. Perhaps that desire is clouding my rationality; I can't say for sure. But I can say that with the population's general mistrust of large institutions growing by the year idea like this are going to look more and more attractive as time goes on.
https://www.google.com/search?q=millennials+distrust+institu...
EDIT: yes I'm sure. As wtallis suggests, isolation is important. But while the battery is still connected, there is no isolation. In that configuration, if you have a tool on the positive terminal connector and it strikes any other conductive component of the car, that's a short, which could heat the tool and burn you (among other things). If instead you follow my advice and disconnect the negative terminal first, when striking e.g. a fan pulley your tool is simply an additional connection from the frame to ground, which has no effect. (After you've disconnected negative, a connection from positive to the frame is not a short.)
Just because something CAN supply 100 amps doesn't mean it WILL supply 100 amps. I can touch both terminals of my car's battery with my hands and very little happens. That's because V = I * R, V = 12 and R ~= 100k so I = 0.12 milliamps or 120 microamps.
Now of course we're talking about 48V not 12V but that's still less than half a milliamp, unless of course you have both of your hands drenched in saltwater and you grab as much exposed wire as you can, in which case the body's resistance is going to be much less than 100k. But for any reasonable adult it's fairly difficult to kill yourself with 48V.
Will people still need to be careful? Absolutely. But the idea is that at least at first, it's much easier to get around codes requiring permits and inspections and whatnot that make it much harder for individuals to do without explicit approval of the government (know how to file a permit? great. are you a certified electrician? sorry...). Given that in many places the government owns, regulates or otherwise has a substantial interest in the electrical utility company this at least temporarily would allow people to do this on their own. The laws could always change, but it tends to take a while at which point there might be enough people doing it that it wouldn't get passed.
http://en.wikipedia.org/wiki/Electric_shock#Body_resistance
Amps, as such, are not dangerous unless we are talking about a current source. But practical current sources regulate their output to a given current value by varying their voltage (so it's back to voltage again).
That said, 48V is high enough to be dangerous. See Oli Gaser's answer:
http://electronics.stackexchange.com/questions/19103/how-muc...
> "You can see that as low as 20V may be dangerous given the right conditions."
It's basically like a welder. I did some welding a couple weeks ago, right around 100 amps. The output voltage of that machine is probably less than 48 V. Still makes a very pretty arc. :)
What will hurt/kill you is the amount of current passing through your body (in particular your heart) and that is determined by the resistance of your body and the potential difference of where it's flowing from/to (I = V/R).
Interestingly, the current required for ill effects is significantly higher for DC vs AC (at lowish frequency) [1]:
BODILY EFFECT DIRECT CURRENT (DC) 60 Hz AC 10 kHz AC
---------------------------------------------------------------
Slight sensation Men = 1.0 mA 0.4 mA 7 mA
felt at hand(s) Women = 0.6 mA 0.3 mA 5 mA
---------------------------------------------------------------
Threshold of Men = 5.2 mA 1.1 mA 12 mA
perception Women = 3.5 mA 0.7 mA 8 mA
---------------------------------------------------------------
Painful, but Men = 62 mA 9 mA 55 mA
voluntary muscle Women = 41 mA 6 mA 37 mA
control maintained
---------------------------------------------------------------
Painful, unable Men = 76 mA 16 mA 75 mA
to let go of wires Women = 51 mA 10.5 mA 50 mA
---------------------------------------------------------------
Severe pain, Men = 90 mA 23 mA 94 mA
difficulty Women = 60 mA 15 mA 63 mA
breathing
---------------------------------------------------------------
Possible heart Men = 500 mA 100 mA
fibrillation Women = 500 mA 100 mA
after 3 seconds
---------------------------------------------------------------
The linked article suggests an across the chest current of at little as 17 mA could potentially induce fibrillation. At 48V, this is equivalent to a hand to hand (assuming the second hand is the exit point) resistance of ~2,823 Ohms.While is this a very low resistance for the body, it's possible with wet hands and a large surface area in contact with the voltage source.
TL;DR You need to do the cost benefit on a case by case basis.
It makes sense to be connected because any excess can be sold back to the distribution company at the feed-in-tariff rate. Plus, what happens when a local power system fails?
There are interesting "moments" when my house spikes in power usage. One is a combination of 'freezer compressor' + 'refridgerator compressor' + heater fan + oven + microwave. (I don't have whole house AC but do have it in one room). I'm getting better at monitoring individual circuits in my house to understand exactly where power goes.
Generally an 'average' day in Northern california my total usage for the day is 25kWh
I'm in a rental sharehouse, there's a 6kW electric heater fixed to the wall in the kitchen / dinning room / lounge area. I suggested to my housemates perhaps we don't want to pay to run that thing, followed by $1200 winter power bill. Maybe next winter they'll think twice about running it so much.
1. Tea kettle, 2 kW
2. Microwave, 1 kW
3. Oven (cooking parbaked rolls for 8 minutes), 3-4 kW
4. The refrigerator may or may not go on during this period, ~0.5 kW if it does
Of course if really necessary I could be more careful with staggering my appliance usage. But as it currently stands I don't worry about using those kinds of power loads for short periods of time.
Those can get "spiky" depending on who is in the house.
... "still useful". Is that the rest of the quote?
"...it keeps the NSA from spying on you."
There is so much market segmentation potential in that one sentence.
http://www.goodreads.com/quotes/21810-it-is-difficult-to-get...
Further, even if it was $5/ft that eventually starts to look good compared to a $20/mo charge to have the privilege of being connected to the power grid. This is a concept that utility companies are actively discussing and implementing: https://www.google.com/search?q=power+grid+monthly+connectio...
If it costs $400 to hook up to a neighbor and it smooths supply/demand enough to where you could forgo the hookup fee you get paid back in less than two years.
Is the $20 number reasonable? Maybe or maybe not. The first article in the results is Arizona where the utility asked for $50/mo and got $5/mo. But I pay $15/mo to be hooked up to natural gas and nobody seems to think that's robbery at least where I live. I suspect that politicians might accept $25/mo or more as reasonable with enough campaign donations.
Welp, I guess I have to take my stupid idea back then huh?