2,964 karma · joined Aug 10, 2010 (16y ago) · 1,700 submissions
comment 1w ago · link · parent
Literally TI even uses TSMC for the digital only stuff they do. The investment for these cutting edge nodes (or even, not so cutting edge. Like say, 10nm) is absurd vs the payoff.
comment 1w ago · link · parent
Do you have information on what “ban unauthorized ones” means? Are you talking about the pre-USB-C days with lightning or something? I’m not aware of any restriction besides perhaps max charge speed on their USB-C implementation if you used a mediocre cable.
comment 2w ago · link · parent
Although ceramic can technically be sharper, and technically is harder, it’s both very difficult to get a sharp edge and that edge is extremely brittle and chips easily.
Steel can be made much more precisely easily, and the sharpness has toughness that won’t degrade as quickly. This lets you make an edge that cuts much cleaner, which leads to better shaped particles. Once you start “mashing” the particles instead of cutting them, grind size distribution gets a lot worse and you start getting more “fines” which leads to muddy cup profiles.
Also, because ceramic burrs are used on lower end grinders, the tolerance on the burrs and the other stuff around the burrs (alignment, shaft, etc) is much worse overall which impacts repeatability, and because you are continuously grinding, repeatability (play or shimmy) translates to worse grind size distribution.
comment 2w ago · link · parent
Why would it? The wealthy people who haven’t allocated their capital to those assets that are depressed from a recession can reallocate to the depressed assets and end up even wealthier on the rebound. People with no money at all don’t have that opportunity to invest.
comment 2w ago · link · parent
comment 2w ago · link · parent
There's some people that care about no plastic at all anywhere (which... is pretty unrealistic considering water pipes are plastic), but usually the primary concern is plastic in the heated water portions. Water tanks on espresso machines are not typically heated.
comment 3w ago · link · parent
comment 1mo ago · link · parent
comment 1mo ago · link · parent
Either way, your scenario of a multi outlet branch circuit on a 20A outlet would also not be correct. Let’s just make it simple: 20 amps of solar gen and 20 amps of power gen, connected as follows:
Panel -> Breaker -> Solar outlet -> hairdryer outlet
The current would flow from the solar outlet to the hairdryer outlet fully, and the measured current through the breaker would be 0. All wires would be at 20 amps and therefore safe. (Lets ignore that 20 amp wire is only rated for that temporarily… continuous draw would be 16a…) No violation of any current limits and no danger.
Now, you could go crazy and connect 30 amps of solar and 30 amps of hairdryers and that would be dangerous, but we’re rapidly getting into the realm of incredulity. As soon as you removed the load/hairdryers you would pop the breaker.
comment 1mo ago · link · parent
Circuit breakers trip bidirectionally, so the circuit breaker itself would protect if too much current is drawn through to the mains panel.
How, precisely, would you get 65A through the wiring on this 40A circuit, if I drew 40A of consumption and had 25A of supply?
The 25A cancels out the 40A, so the upstream feed would only see 15A total. You do get 65A of total current drawn through the breaker panel, which is a concern, but the supply wiring would not see 65A. Subpanels (which, this would be a subpanel if it only had 40A capacity) are typically going to be just fine.
comment 1mo ago · link · parent
This has very little to do with the power meter itself, and more that the power company wants to be able to monitor if the meter is 'running backwards' (i.e., if power is flowing out rather than into the meter). Older meters could only run in one direction.
> Clearly some people think of it differently if they're plugging generators into wall sockets to power the whole house, dumb as that may be.
There's frankly nothing wrong with this if you do it properly. The 'proper' way would be to have a generator input socket near the main breaker panel, and the main breaker is interlocked with the generator input (i.e., only one can be on at a time). You absolutely can just plug a regular generator into a wall, assuming you aren't overloading the wiring or breakers... the safety issue is overblown. The reason why it's 'super dangerous and bad stuff will happen' is because people are stupid and forget to turn off the main breaker. Which, admittedly, is a reasonable concern because... people do forget.
comment 1mo ago · link · parent
20% is 20%. Unless you're moving from one tax bracket to another on a particularly steep threshold, a 20% raise is going to actually translate to close to 20% extra take home, especially at the income levels for someone making $3k/mo take home.
comment 1mo ago · link · parent
Health insurance yes, retirement… no, not really. They may offer a 401k plan and some might even offer a match, but most companies offer at most a 4% salary match (dollar for dollar, or sometimes 50c per dollar).
So, it’s a vehicle to invest retirement funds with some tax advantages, but it’s not really “providing” it like you would subsidized healthcare.