comment 2w ago · link · parent

These days there's usually two networks. Multi-trillion parameter models are too big to fit on one box of 8x H100's, so many of these are running RDMA (800Gb/sec on GB300 series) for rack-scale/many row-scale inference.

For GB300 series, pricing along the lines of $500k/server, 9 servers/rack ($4.5M/rack) before looking at water cooling, 800Gb RDMA network, and your 100Gb IP network

comment 3mo ago · link · parent

> until the train went off the rails

Ironically the core application is written in rails, which may be part of the issue

3.

Mark J. Wielaard (Mjw) Receives Distinguished Service Award in Software Freedom(sfconservancy.org ↗)

5 points · by darkr · 3mo ago · discuss

4.

The Unreasonable Power of Identifiers(cogna.co ↗)

5 points · by darkr · 4mo ago · discuss

comment 5mo ago · link · parent

C is a weakly typed language. It’s statically typed, which is a different thing

comment 7mo ago · link · parent

For customers who repeatedly do this - put your prices up by 10%. Offer 10% discount for paying within net 15.

comment 8mo ago · link · parent

> iPad Air is a fantastic value

TIL American English treats “value” in the financial sense as a countable noun

comment 9mo ago · link · parent

It’d be nice to have in stdlib, but it’s pretty trivial to write a generic wrapper for it

comment 10mo ago · link · parent

air source heat pumps, though they're improving won't do well in extreme cold; even if they can operate they'll still be running at much lower efficiency.

For temperatures significantly into negative territory a ground source heat pump would perform far better, where it can draw on a source of heat that will always be at least above freezing.

A hybrid system doesn't seem like a bad trade-off though..

comment 10mo ago · link · parent

yes - this is also part of the privacy extensions spec: https://datatracker.ietf.org/doc/html/rfc4941

comment 1y ago · link · parent

It’s not uncommon. Google AIP spec requires it for example. I think the main driver for it is implicit idempotency.

comment 1y ago · link · parent

It's basically a long form linkedin article.

comment 1y ago · link · parent

Incorrect

comment 1y ago · link · parent

At least historically, google engineers had 20% of their time to spend on projects not related to their core role

comment 1y ago · link · parent

> IMO the culling over managers over the past few years is really a way to make sure you don't have someone you can discuss career development, promotion, and pay increases with

That’s the point, surely

comment 1y ago · link · parent

> those nuclear weapons quell a lot of our more violent habits, hasn't been a world war since

It’s only been 85 years, give it a bit more time…

comment 1y ago · link · parent

The first season is a masterpiece. Second season goes off the rails and loses direction fairly early on

comment 2y ago · link · parent

Similarly python in optimised mode with -O or -OO flags will disable asserts.

I see asserts as a less temporary version of print() based debugging. Sometimes very useful as a quick and dirty fix, but 9 times out of 10 you’re better off with some combination of a real debugger, unit tests, tracing/logging, and better typing or validation.

comment 2y ago · link · parent

Great PR move, but surely better to invest in more basic security measures supported by their app (chain of trust, verified callers/messaging etc). Instead their app is primarily a react native sales tool. Part of the reason that o2 was so affected by scammers calling from south Asian call centres with “the latest offers” was because they used to do exactly this with their customers.

comment 2y ago · link · parent

Americans are weird. I’ve been going to the same barber for years. He doesn’t know my name, barely says a word and it’s just so comforting.

comment 2y ago · link · parent

If there’s any scope for a user to inject JavaScript, then potentially this gives a vector of attack against other internal things (e.g admin.domain.com, operations.domain.com etc)

comment 2y ago · link · parent

https://security-tracker.debian.org/tracker/status/release/s...

comment 2y ago · link · parent

Cheap stud finders are usually not great. The good ones are radar-based using similar frequency bands to wifi, but they cost lots of $$

comment 2y ago · link · parent

In the UK, dew point highs will peak above 22 degrees multiple times per year, so the safe temperature to cool to is something like 25 degrees.

Might provide some benefits on really hot days, but it’s still uncomfortably warm for working in.

comment 2y ago · link · parent

It would only need to be 4.7 to beat a gas/oil system that is 100% efficient.

In reality, a very good gas based system that is well specified and installed might reach 80% as a whole. Most UK gas/oil heating systems are significantly lower.

comment 2y ago · link · parent

WRT cooling with water based system there are a few of issues:

1. A system that also provides cooling isn’t allowed under the heat pump government grant.

2. You might actually need planning permission for this

3. Especially in a humid environment like the uk, you can end up with condensation and damp issues, which you really don’t want in an underfloor slab install

If you also want cooling, better to go an air-air based system (aka air conditioning)

comment 2y ago · link · parent

Those figures are for the unit itself. It takes a lot less energy to heat air than it does to heat water, but water retains heat for much longer.

What matters is the SCOP for the system as a whole.

In a traditional Victorian house with a fireplace in every room, radiant heat will provide far greater efficiency than a forced air system, in which all of that warm air will literally go straight up the chimney.

comment 2y ago · link · parent

Another issue with heat pump rollout, at least in the UK is a severe lack of qualified heating engineers with a basic understanding of thermodynamic principles.

Thus you get plumbers with experience installing gas boilers, resulting in poorly specified and installed systems that provide nowhere near the efficiency that they should reach.

This then leads people to say “heat pumps don’t work” or “heat pumps are expensive to run”, which only feeds into the whole anti net-zero rhetoric.

comment 2y ago · link · parent

This. The cost of installing and upgrading a big old drafty Victorian house to a COP 4+ efficiency where the running costs actually beat oil/gas would have a break even point way past the end of my lifetime.