Better HN
topnewbestaskshowjobs
Log inSign up

namibj

2,539 karma · joined Jun 28, 2017 (9y ago) · 2,648 submissions

I'm just a Software Dev form Germany. Contact (Keybase.io) user "namibj". Other contact info linked from there.

[ my public key: https://keybase.io/namibj; my proof: https://keybase.io/namibj/sigs/h5xIkE5xYZSZ2QRUTK4HJNj2ffIfMYC2DSNmRSmFZno ]

Submissions

comment 2d ago · link · parent

If your from the USA: European courts work differently in jurisprudence aspects from USA courts.

comment 3d ago · link · parent

Probably also a factor of low wing loading and corresponding lower take off speed and shorter runways (potentially available closer to destination) forcing you higher to have good efficiency at maximum mach number/peak aerodynamically safe speed, with a side effect of being over top of more if the weather and mainstream traffic to enjoy more direct routes.

comment 3d ago · link · parent

Also these intercooler-free turbofan propulsion plants have a big issue delivering good power at high altitude.

The https://en.wikipedia.org/wiki/Grob_Strato_2C for example had a Continental IO-550 core surrounded by a total of 3 spools of turbocharging, and employed charge-air intercooling after each of the 3 compressors. It flew it's endurance record at FL590 and it's useful service ceiling was FL787. For economy and given that it was a turboprop, it only flew Mach 0.56, but that's not directly connected to the utility of charge air cooling at high altitudes.

You could use a turbine core just as well instead of their 4-stroke gasoline engine.

One stage of intercooler might be quite effective for the modern 2-spool turbofan units if you want to make them fly higher? So that the default cruise height goes up from a reduced wing loading despite maintained/typical MMO speed.

comment 5d ago · link · parent

You see, at least when we're talking about summer heat AC, you can just build more of the panels and feed the much flatter baseload to industry that prefers to run the capital intensive machinery not only when the sun shines high during the summer.

If we're talking about winter heating in for example German climates, you'd have to over build so much solar capacity to handle cold winters (even if we're willing to turn on fuel burning supplementary heaters for a statistically single digit number of days per year) that you have severe excess in summer.

You'd turn most factories (those with decently high electricity draw per capital expenditure) off for about a month worth of days in winter, usually combining this with scheduled maintenance, and:

To further shift large amounts of country-scale power consumption from year-round/winter to only sunny summer days: try to set up electrical refining of (purified) iron ore into (metallic) iron at larger solar farms where you could recycle their grid connection and their AC/DC converters together with already normalized (for there) local batteries (to shift delivery of half the production from around noon to the night, which reduces the AC/DC converter capacity and the AC grid connection/transformer size requirements). There are realistic low-temperature electrolysis options for electro-chemically splitting the oxygen off of the iron (purified iron ore is iron oxide) like Siderwin [0] and even near-room-temperature options like Electra [1].

For scale, [0] claims replacing the production of the existing coal-based iron ore refining plants of Europe with Siderwin would require 471 TWh/year in additional electricity in the grid; [2] claims the EU (without the overall insignificant island Malta, as it's not connected to the continental grid in a way that'd be readily suited to inclusion in these common-measurement-definitions statistics) produced 2497.3 TWh in the entire year of 2024, of which 237.6 TWh were solar.

Thus, it's overall "not that much" extra production capacity that'd even be spent on this (assuming an essentially-fully renewable grid, let's call it 99% by yearly aggregate electricity production): during heavy solar days, you'd import solar power from the grid at night, aim for something like 5~30% yearly average utilization of the electricity-guzzling iron-deoxidizer, and feed excess summer production into the iron-deoxidizer day and night via the local batteries. There's an overlap zone in grid daily solar yield, where you'd even import from other solar plants, depending on how expensive a kW of iron-deoxider capacity is vs. a kW of solar panel (with MPPT, but without AC inverter). Expensive solar and AC-grid means you'd import more on very sunny days (use the other solar plants instead of just discarding their power, as you'd run with no exported AC during daytime and suck the other plant's batteries dry at night, with more local iron-deoxider kW than day-average peak solar kW; local batteries do the flattening of the local solar power across the day/night cycle), while expensive iron-deoxidizer kW force you to run it more continuously across the summer months with only brief exceptions during some sporadic weeks of clouds (where you want big industry to just power through instead) despite this wasting solar power during summer daytime that can't be stored in the local batteries and can't be exported to the grid (on such peak sunny days, the plant would have to throttle the panels during the afternoon once it's local batteries hit 100% around noon).

It's around 1/6th of current yearly electricity production; at say 33% duty cycle however it'd approximately look like 1/2 of electricity production (during the third of the year where solar is in excess), so we'd be talking about a massive grid capacity impact. Hence the proposal/suggestion to move it to the DC side of solar farms that are large enough to warrant the staffing/infrastructure overhead.

[0]: https://industrydecarbonization.com/news/making-steel-with-e... [1]: https://www.electra.earth/our-technology/ [2]: https://eepublicdownloads.blob.core.windows.net/public-cdn-c...

comment 1w ago · link · parent

Use the hot spare cable loop to yell at people. No occupancy without two working ones; this means you want a third so you can do maintenance without having to evict occupants first.

comment 1w ago · link · parent

Do note that you could go for technology like the 100 hour ("0.01C") iron-air batteries "form energy" works on, especially if you're willing to swap them in port instead of DC fast charging through a temporary high voltage link.

You'd get the benefit of charging them when it's sufficiently convenient (off-peak), and the lower energy density and very low power density don't matter nearly as much on a ship.

comment 1w ago · link · parent

Assuming 100$/kWh and those 2G$ (giga/billion), a full charge would be 20 GWh.

Realistically: probably exposed wire like on regular high voltage pylons. Hooked to a not-too-far (the wires will be on the larger end, but you likely don't want the other end to be anywhere it could get in the way of cargo operations, and given the voltages involved, you can probably get half way across the city before it really begins to matter) grid battery bank that normally takes care of day-to-day scale grid balancing/energy arbitrage.

Then you just run a (group of) wires to the ship and apply basically the same principles as those DC fast charge stations for cars, except that you feed the high power DC link of the charging cable from the shore-side battery through much more efficient and importantly cheaper DC/DC regulators instead of involving transformers and AC.

You obviously have remote-controlled switches and circuit breakers to keep those cables grounded while the workers hook them up. You'd probably have several DC links that have their own DC/DC regulators and can be split between ships. Mostly also because there's a limit to how high-current any individual cable/connector is made in practice and because you want to use the current rating on your DC/DC converters and the thick-but-off-the-shelf cables between the battery park and the pier.

Note that these are huge: the largest grid battery plant in operation (according to https://en.wikipedia.org/wiki/Battery_energy_storage_system ) is only 4GWh, so 1/5th of such a ship.

comment 2w ago · link · parent

Discount?

comment 3w ago · link · parent

Yeah, allow loans as appropriate, but stocks ("ownership") should come with voting power exactly proportional to their face value.

Otherwise you're subsidizing oligarchs by cutting investors off from kicking the board the next week if/after it's caught acting against the share holders.

comment 3w ago · link · parent

If you can stay there (no evacuation for building doesn't seal enough to make it habitable), most of the solar should have survived. Moving a broken panel out of the way and swapping one from the end of the array in to make the cables fit, or even having a spare jumper cable to swap in place of a broken panel, is quite easy to do. Mostly just make sure there's no load current at all on the string when you disconnect the MC4 connector with the special tool that keeps uneducated people from unplugging them under load and getting greeted with a persistent low current (not "arc flash", we're in the region of "high powered welder used with just normal welding PPE") DC arc (that may supply several hundred volts for a long drawn out burn). As long as it's around substantially below 500 mA you're not gonna sustain an arc.

comment 3w ago · link · parent

Oh, such tactics are still applicable to dehumidify outside air in an air source system (and possibly further extract enthalpy by freezing off the excess water captured in the "wet scrubber").

In general, using heavily salted water (not sodium chloride that's quite ineffective) to dehumidify humid cold air during heating and reject heat with a wet interface without having to source potentially scarce water to evaporate, is quite an intriguing alternative to classic fan-laden AC "condenser" coils.

Incidentally, KOH is also interesting as it dehumidifies down to quite low humidity (at least indoor-facing) before it saturates (and precipitates out), and as a side-gig scrubs CO2 that can be precipitated out with CaO/Ca(OH)2 as CaCO3 (limestone).

This can be thermally recovered at around 800~900 C to essentially "boil" the CO2 off.

IMHO a chemically appropriate wet heat exchanger based on (cross flow: easy) or (counter-flow: harer to prevent droplet formation) with just a simple corrugated structured packing should be able to operate more hygienically than a theoretically dry, practically humidity-condensing classic mini-split AC coil. And allow most dust to be washed off fully automatically from normal operation. It'd "just" need a regenerator to dry out excess unwanted humidity, but I'd assume there's a reasonable way to boil off the excess humidity from the "salty water". Maybe the common reverse-osmosis filter materials can resist these chemicals; in that case it'd sound like a question of pressurization energy recovery; or it could be put under vacuum and a small heat pump could transfer the enthalpy of vaporization from the condenser [distilled water plus dissolved gasses, vacuum] (that isn't fully flooded due to presence of dissolved gasses in the feed) to the evaporator [salty water, same vacuum]. If the ratio of dissolved gasses relative to the extracted condensate is small enough, I'd guess a water jet "ejector pump" using that very condensate (after it's cooled down enough to not boil in the ejector) would actually work to provide the vacuum for continuously pumping the dissolved gasses that boil out along the humidity... A small centrifugal pump for that can easily be made completely sealed using magnets to transmit the torque to the impeller and a long life ceramic bearing, at least if there's a long enough pipe down to the pump to build minimum inlet pressure (against cavitation).

Also: For vacuum btw. remember the convenience of using gravity to pull a (nearly) 10m column of water down. Dissolved gasses are likely the dominant complication.

comment 3w ago · link · parent

You can use dehumidifiers at a fraction of the power cost of full air heating, given that you only need to keep the surface pores of the e.g. wallpaper below a humidity that supports mold growth. Similarly, the bathroom could gain a second insulated door-ish curtain for an airlock effect fairly easily.

comment 3w ago · link · parent

A big problem towards full electrification are those resistive extra heaters, due to their correlation across entire cities and correlation with extremely poor solar yields.

Unless there's a particular good reason to it's actually not too bad of an idea (with a hot water radiator loop in the home at least) to keep a fuel burning radiator loop heater around and just valve it off to not interfere on normal days. Especially if the heat pump is air source (which the mentioned swedish one isn't).

It's not that I'm against full electrification, but peak cold spell heating in excess of the heat pump capacity is among the last things we ought to "electrify by force."

We'd have massive summer overcapacity at the point where we can generally afford to "just do that". And chances are that it'd not be a resistive heater but a heat pump freezing a pool worth of water to cap the cold side temperature at just under 0C, or something the like, just because of how grid intensive the correlated load of those resistive heaters is.

It might even be cheaper to use synthetic fuel produced in summer than to 100% electrify that cold spell heating capacity. Carbon capture is expensive but there are options from e.g. domestic waste incinerators, paper making, and generally waste wood/plant matter decomposition, where hydrogen can cheaply be added to produce methane (pipes) or propane/butane (tanker trucks with liquified gas).

comment 3w ago · link · parent

Yeah it was a radar that could collect the echo on the next rotation of Earth.

comment 3w ago · link · parent

What proofs are good for is decoupling implementation and semantic definition of software (and application specific circuits).

Like, proving that in the absence of hardware faults, some optimizer for JavaScript can never result in arbitrary memory accesses.

Or that some database doesn't violate data semantics under ANY condition.

Or that as long as not too many sensors fail, a plane autopilot will not go and do anything that would lead the plane to exceed safe speeds and forces/accelerations. (Won't just go crash the plane or drop it from the sky in one or more pieces just because some few sensors froze or caught lightning or something.)

comment 3w ago · link · parent

Because rail is quite non line of sight and quite infrastructure defined pathing.

The automatic coordination system hit a fail condition; they neglected the fallback protocols that had rules for spacing determined to work reliably without the computer keeping real time supervision; they crashed.

This is in the way more like the Washington D.C. helicopter plane mid-air where some normalization of deviance got people to ignore automated protection systems.

If most involved had known the fallback protocols they would have refused to move/continue while the protocols were utterly neglected. At least with a robust safety culture active, ofc.

comment 1mo ago · link · parent

Closed loop control is very effective (where it's available). Of course that's not always usable and thus some tasks do necessitate the stage to provide such positioning precision as absolute accuracy not merely precision.

comment 1mo ago · link · parent

Does anyone have a link to a 6DOF version of what this does? Like, the design principle would easily function for a hexapod (swap the dual-rod linkages for single-rod and manage to pre-load the result; add 3 more motors, change how the actuators are arranged relative to the platform they manipulate), but it'd be great to see at least predicted work volume and/or translated stiffness/precision numbers that e.g. adjust from this project using the different kinematic equations, before I'm investing a bunch of R&D into figuring out how best to orient things and whether I may want that to rely on AppliedScience's diy vacuum preloaded spherical air bearings that could probably take care of the necessary pre-loading of the mechanism; machining a graphite block into a hexapod movement stage side "platform triangle" (the floating part that moves) doesn't really need force after all, just sufficient control over where the milling tool/drill is, and obligatory effective dust collection lest the workshop gets a strong dusting of graphite powder. Attaching ball bearings balls to the rod ends would probably be one of the hardest machining part of the entire idea.

But this 3d printed rubber band preloaded journal bearing concept is also intriguing for it's simplicity, even if it's probably more limited in usable range of motion.

comment 1mo ago · link · parent

The UI is a ring laser gyroscope, right?

comment 1mo ago · link · parent

These collective nouns are mostly from an old book, and half of them in there weren't ever meant to be serious.

https://en.wikipedia.org/wiki/Book_of_Saint_Albans

comment 1mo ago · link · parent

I want to remind that natural gas fired heat pumps operating with central European winter temperatures on the cold side and toasty warm indoors living room "by the fire place/any clothes are too warm just sitting not even exercising at all" are well established technology.

They're just usually deployed for frozen warehouses, factories that actively freeze large amounts of (usually food), and AFAIK the occasional ice(hockey) rink.

Shitty types that don't even bother with any decent controls/pumps (those 90% boilers use a water loop circulation pump and a combustion air blower together with a bunch of sensors and valves) run propane-fired in many camper vans to do the fridge. But at the scale of an apartment building fit for 50+ residents, a natural gas fired central heat pump can be _quite_ efficient and economical.

Thermodynamically they're a heat engine with high combustion/flame temperature that uses the warm side as the heat sink, mated to a heat pump that consumes the produced "mechanical/electrical grade" power to pump heat from the cold side to _also_ the warm side. You save the turbine! Also the electrics but they're probably not even that expensive relative to the rest of the 200MW-class combined cycle natural gas power plant.

comment 1mo ago · link · parent

I'm pretty sure the barrier to the lead-gold mass parity is that due to nuclear stuff they're gonna not trade equal proton/neutron count and while of you flip the ratio you are merely dealing with an energy deficit/excess incurred as you're rearranging the protons and neutrons to transmute between gold and lead which by e=mc² is equivalent to mass... You're gonna run head first into the problem that we with our current proven understanding of atomic nucleus quantum physics, expect the energy excess to need to be turned into an equal split of matter *and antimatter*, which will foul your plans.

We're suspecting there to be some symmetry breakage to explain why we don't really see any globs of antimatter with our telescopes (at least none that show any evidence of being antimatter), but so far no (real) luck.

As for the "0.13€ vs. 1€": you're not gonna get much solar yield in peak winter at least in Central Europe, especially it's gonna be that your PV is going to charge <100hour electricity storage when the sun shows up on those winter days and the heat pump (at least the part that spends a little electricity to lift a lot of heat energy from outside temps to indoor temps) runs approximately continuously.

You might have some kind of e.g. water/water heat pump with salted (not table salt though) water deliberately thawing during daytime (by turning on the circulation between it and outside air) to freeze at much warmer than night air temperatures to buffer those "only mildly freezing" temperatures to improve the efficiency (and at that point, likely also the thermal output power) of the heat pump.

The radiators inside and potential fans for them would also go up in flow to make up for the increased losses through the walls/window-glass.

A big reason why at least in e.g. Germany heat pumps are not at all irrelevant vs. electric resistance "space heaters" is that they're also very efficient at handling spring/autumn (lower thermal delta to lift against; referencing to a resistance heater for scale/reference purposes but clearly not expecting that to be a benchmark) while easily offering summer cooling (with relatively minor incremental complexity).

I don't really know how inherently expensive it is to keep around at least for parts of each city, but existing natural gas central heating boilers are very useful to not just trash before they're broken just because one uogrades to a heat pump, specifically because they are already there (sunk cost/little scrap value) and have basically zero issue delivering extremely spiky power during unannounced winter days (well, takes maybe a day of notice to actually get crew in to the storage&distribution facilities, but weather forecasts easily cope).

Sure, it's not _efficient,_ but we could just divert some synthetic methane during summer to refill the caverns: we kinda want that (at least for hydrogen but methane works too at least for storage) anyways for chemical synthesis factories if we're not just gonna feed them crude oil/natural gas, so other than that chemical factories probably/largely prefer direct hydrogen, continuing to use our existing seasonal storage even if it's not getting refilled from NordStream2 but from local summer-only electrolysis plants and with more hydrogen than methane where the geology allows, seems to me just frugal dealings with nature (reduce, Reuse, recycle).

comment 2mo ago · link · parent

Start by using wet Roomba tech to clean the port prior to opening the seal/door and doing the plugging? Assuming it's accessed from below.

comment 2mo ago · link · parent

Sorry about the writing :(

We have beaten it but only for an output that's approximately "green smoothie".

We're already better than just LED grow lights for e.g. lettuce, though, from how I recall the linked paper.

Unsure how you conclude that cold outdoors necessitate more meat though; aside from some micronutrients vegan diet works just fine so reverting back to "meat only on Sundays" 1910 style household dinner menu structures would work fine...

Most people could, for example, do with replacing the caloric intake from half the portion of any non-vegan food they consume, with potato.

If outdoor farming breaks from climate meat will get more expensive...

Vertical solar panels mounted like fence panels between fence posts high enough to not get covered by snowdrifts will produce electricity year-round; and we only need around 3x as much solar farm currently to power sealed grow "basements" than the same plant output would need if just farmed on an open field (assuming climate is matched and weather is average). The benefit of it is just that the panels can be other places (like noise barrier walls next to an urban highway) than the plants and the climate can be freely picked. Also no unlucky correlated dry spell weather events that can cut 100 million people's worth of harvest yield down to half or worse.

Grow houses won't fail collectively as much as farming weather is correlated across a region. Pretty much just need to keep measures around to prevent the plants from freezing just because the electric grid falls over for 3 days in winter.

comment 2mo ago · link · parent

You can just render to the 1bpp text/4bpp images monochrome 300dpi target; perhaps some tone mapping due to the limited contrast ratio of the eink vs. your OLED should be done at rasterization time.

Then just map the resulting 16 brightness levels according to the contrast ratios/progression they have on your eink. Use phone camera and adjust whole image contrast/brightness/black-intensity sliders holding them side by side until the grayscale matches.

Then just pick pixel RGBs from a gray-bars test image you have opened on the remarkable before you took the picture with your pixel 7 pro. Might not easily be done on the phone but can let a python using AI grab those for you. (If it's wrong it'll be obvious or so harmless it doesn't matter anyways.)

Then you take that rasterized-to-1/4-bpp-djvu apply the color palette you just built yourself, and zoom to 300dpi.

Other than the screen backlight which you've taken care of when you held both devices side-by-side and played with the sliders, there's no substantial difference left. Should be pretty representative. Don't look with too much of a magnifying glass though the phone doesn't have exactly the same dpi so there are resampling artifacts your eyes resolve if you're too close to it.

comment 2mo ago · link · parent

The big thing that was learned all the way back with UT and it's follow up SUT was that semantic nesting structure often incentivizes models that can deploy the very same learned structural parsing intelligence independent of how many layers of nesting had to be unwrapped for this structural pattern to surface.

Think how a reverse polish notation calculator with reasonably limited data stack depth could run efficiently with a plain vanilla transformer.

But if you input classic grade school parenthesized infix with a few levels of operator precedence, you are no longer able to just evaluate the expression during transformer prefill. Even if you add a stack depth bound worth it reasoning tokens between any two input tokens as they're processed.

UTs can, at least if run with encoder (unmasked) attention, resolve the task through technically-flexible iteration count that can and will follow the evaluation order of the infix operator tokens of the input expression.

While masked attention unfortunately limits it's powers, the fundamental benefit of separating task-specific-intelligence (an individual expert of an MoE) from the notion of which transformer layer has it pre-digested just right for that task/processing to be done to it, allows for massive reduction in model parameter count. Note this comes at a penalty of parameter activations (inference will take more compute).

It's just that at some point you can't afford to just train more parameters, without suffering overfitting issues/failures-to-generalize.

The architecture decoupling learned weights from when they're activated also helps with generalization to out-of-distribution structures. Think resilience against yoda-speak and such.

comment 2mo ago · link · parent

Oh, is the principle of sparse universal transformers finally in SoTA LLMs?

I guess we did manage to eventually seriously crash into the wall "more compute than normal (non-looped/unique-weights) transformers can efficiently consume with the limited training data we have", plus massive focus on highly hands-off agentic tool use reasoning...

https://arxiv.org/abs/2310.07096

Edit: read much of the article, it's brute force predecessor was explicitly called out as an almost-ancient example:

> The looped transformer is nothing new, and the basic idea already appeared in the Universal Transformers paper from 2018

comment 2mo ago · link · parent

For fast updates / high frame rate, especially also smooth fade from previous to next page, those displays only do black/white. They can typically modulate about 14 levels of gray in-between but reliably (without really bad ghosting, due to strong temperature sensitivity of the pixel's transition response and the display being static so all gray has to be done by carefully interrupting a transition part way through) only from a nice flash-to-black -> flash-to-white -> fade-to-target-greyscale (sometimes one or two alternating full contrast flashes prepended to more intensely equalize the pixels/erase ghosting, but should only be needed every couple dozen page flips in grayscale mode).

I think the nice b/w no-flicker fade transitions chop the transitioning of all changing pixels into small burst/chunks and interleave/alternate the chunks of white-to-black with the chunks of black-to-white, so it's perceptually simultaneous. Or it's actually pulling off some kind of tri-state driving leaving unchanging pixels alone and pulling those that change to either plus or minus polarity depending on what transition direction they are supposed to go in... Sadly IIRC all quite proprietary-gated :(

What that means for djvu is that at least for text-only content on those readers that manage the 300 dpi "threshold" you'd just rasterize to pure 300dpi black/white (1 bit per pixel) comparable to a 300dpi "don't skimp on toner but don't you dare take half a second longer than you must in order to make the text crisp enough for $reader to have no good reason to whine about it being not crisp enough" laser printer job.

Djvu is particularly for displays with more than about 5bits of grayscale as well as for lossy compression of grayscale/color scans. And maybe also some efficiency gains on 1-bit-per-pixel quantized scans, but those aren't usually the target content for these readers, IMO. Might want to try for them, though!

comment 2mo ago · link · parent

I think back in the days before office workers that happened to do their work on a computer had access to the ancient relatives of "Microsoft Word"/"Libreoffice Writer", it was pretty normal for printers to take care of plain text files, with about as much fidelity as manual operation of a classic purely mechanical Typewriter.

Since then printers progressively forgot how to cope with such "documents", though IIRC good-old HP "PCL" should only require about a bare minimum of framing/job control to get a modern printer to handle ASCII plain text.

comment 2mo ago · link · parent

Yeah but you can train to perceive the threshold of impending over-hydration and adjust your behavior trigger thresholds to bump up against that more than you bump up against clearly perceived acute dehydration ("very much obviously clearly thirsty").
12345