Better HN
topnewbestaskshowjobs
Log inSign up

raffihotter

96 karma · joined Feb 13, 2019 (7y ago) · 24 submissions

rhotter.github.io
Submissions

1.

Squirrel Monkey Skull(squirrelmonkeyskull.com ↗)

2 points · by raffihotter · 1y ago · discuss

2.

Parrotify.me: Turn Yourself into a Parrot(parrotify.me ↗)

4 points · by raffihotter · 1y ago · 1 comment

comment 1y ago · link · parent

Thanks for sharing this! Linked it on the website.

comment 1y ago · link · parent

I added an explanation to the page! Hope it's helpful.

comment 1y ago · link · parent

im still working on ultrasound stuff, but specifically for BCI! https://news.ycombinator.com/item?id=42021450

comment 1y ago · link · parent

fixed! sorry about that, and thanks for the feedback

comment 1y ago · link · parent

Hmm, looking into this.

8.

Spherical Harmonics(rhotter.com ↗)

107 points · by raffihotter · 1y ago · 62 comments

comment 2y ago · link · parent

Totally agree regarding not extrapolating to 10 MHz.

I had went down a huge rabbit hole to find the source for the 22 dB/cm/MHz paper that everyone quoted. People reference the Diagnostic Ultrasound textbook; that textbook references an old nondigital ultrasound reference book, which finally references a Fry paper from 1977 [1].

It's funny because the Fry paper never explicitly mentions the number 22 dB/cm/MHz. But there was one figure (Figure 12), where if you fit a line through the data in that figure, you get a slope of 23.5 dB/cm/MHz.

Here's a spreadsheet of me fitting the data: https://docs.google.com/spreadsheets/d/1a70svm-zrzp1SQT5v2m_...

But yes, you're totally right that even the Fry paper Figure 12 was only up to 2 MHz, so it's totally not fair to extrapolate to 10 MHz.

[1] https://pubmed.ncbi.nlm.nih.gov/690336/

comment 2y ago · link · parent

To open the BBB, I believe you either need (1) microbubbles or (2) much higher pressures than what we'd use.

Ref: https://pmc.ncbi.nlm.nih.gov/articles/PMC9029131/

comment 2y ago · link · parent

You don’t. The bubbles only form once the skull is outside the body. When it gets out of the body, the gaps that used to be filled with water get filled with air.

comment 2y ago · link · parent

To my knowledge, transcranial doppler doesn’t form images. It just gives you a single channel measurement that is very low resolution.

The method we’re proposing would have mm resolution.

comment 2y ago · link · parent

Precisely

comment 2y ago · link · parent

Thanks for your questions! I was one of the people who worked on the project. To answer your questions:

> Is it fair to say that their claims about spatial resolution being >>> existing EEG options are jumping the gun? If I understand correctly, you need to be targeting individual 1mm^2 regions with individual acoustic lenses, which means 17,000 channels would required 17,000 separate, uniquely-tuned ultrasound emitters, yes? Even if that's possible without messing up the data (the MHz range is big, but is it that big?) it seems like a trivial impossibility to fit that in one headset -- even the standard 32-64 EEG channels alone seem like a long shot. But maybe I'm overly cynical, or one emitter could be used to usefully excite multiple regions at once?

Since the system is linear, you could use a single probe to focus at multiple spots. Each focus would be at a slightly different modulation frequency.

> Another oddity in that paper is that it reads like we're trying to find persistent signals in the brain, like a needle in a haystack, whereas my understanding was that the field is moving decisively towards tracking signal changes over time in a given region. Is my intuition correct that accounting for a moving target would add considerable complexity to this approach?

This method would indeed let you track signals that change over time. Lock-in-amplifiers can output time-varying signals.

15.

Impossibility of Neuralink Compression Challenge(twitter.com ↗)

3 points · by raffihotter · 2y ago · 1 comment

comment 2y ago · link · parent

200x compression on this dataset is mathematically impossible. The noise on the amplifier and digitizer limit the max compression to 5.3x.

Here’s why: https://x.com/raffi_hotter/status/1795910298936705098

17.

On Learning Outside Institutions(rhotter.com ↗)

2 points · by raffihotter · 3y ago · discuss

18.

Typewriter with ChatGPT(merny93.github.io ↗)

3 points · by raffihotter · 3y ago · discuss

19.

ChatGPT Typewriter(merny93.github.io ↗)

2 points · by raffihotter · 3y ago · 1 comment

20.

Machine Learning for MRI Image Reconstruction(rhotter.github.io ↗)

79 points · by raffihotter · 4y ago · 46 comments

comment 6y ago · link · parent

Hi HN! We're building a micro-campus and community for young people filled with curiosity and kindness.

There will be a rigorous COVID protocol and it will operate as a bubble with no outside interactions.

We plan on building things (and working/studying!) in the company of like-minded peers.

If you’re even a little bit curious, give our website a visit!

22.

School 2.0(school2point0.com ↗)

5 points · by raffihotter · 6y ago · 1 comment